45 research outputs found

    Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique

    Get PDF
    Phase variance-based motion contrast imaging is demonstrated using a spectral domain optical coherence tomography system for the in vivo human retina. This contrast technique spatially identifies locations of motion within the retina primarily associated with vasculature. Histogram-based noise analysis of the motion contrast images was used to reduce the motion noise created by transverse eye motion. En face summation images created from the 3D motion contrast data are presented with segmentation of selected retinal layers to provide non-invasive vascular visualization comparable to currently used invasive angiographic imaging. This motion contrast technique has demonstrated the ability to visualize resolution-limited vasculature independent of vessel orientation and flow velocity

    Imaging vasculature independent of direction of flow using spectral domain optical coherence tomography

    Get PDF
    A variation to the analysis of phase data achieved with spectral domain optical coherence tomography (SDOCT) is presented. By using the variance of the phase changes observed in the OCT images, scatterer motion has been imaged which is not readily observable with conventional Doppler OCT techniques. Dynamic motion contrast has been demonstrated for imaging Brownian motion of a sample system as well as imaging vasculature of in vivo 3dpf zebrafish

    Imaging vasculature independent of direction of flow using spectral domain optical coherence tomography

    Get PDF
    A variation to the analysis of phase data achieved with spectral domain optical coherence tomography (SDOCT) is presented. By using the variance of the phase changes observed in the OCT images, scatterer motion has been imaged which is not readily observable with conventional Doppler OCT techniques. Dynamic motion contrast has been demonstrated for imaging Brownian motion of a sample system as well as imaging vasculature of in vivo 3dpf zebrafish

    Visualization of human retinal micro-capillaries with phase contrast high-speed optical coherence tomography

    Get PDF
    We present high-speed Fourier-domain optical coherence tomography (Fd-OCT) with the phase variance based motion contrast method for visualizing retinal micro-circulation in vivo. This technique allows non-invasive visualization of a two-dimensional retinal perfusion map and concurrent volumetric morphology of retinal microvasculature with high sensitivity. The high-speed acquisition rate at 125kHz A-scans enables reduction of motion artifacts with increased scanning area if compared to previously reported results. Several scanning schemes with different sampling densities and scanning areas are evaluated to find optimal parameters for in vivo imaging. In order to evaluate this technique, we compare OCT micro-capillary imaging using the phase variance technique with fundus fluorescein angiography (FA). Additionally, volumetric visualization of blood flow for a normal subject is presented

    Optical imaging of the chorioretinal vasculature in the living human eye

    Get PDF
    Detailed visualization of microvascular changes in the human retina is clinically limited by the capabilities of angiography imaging, a 2D fundus photograph that requires an intravenous injection of fluorescent dye. Whereas current angiography methods enable visualization of some retinal capillary detail, they do not adequately reveal the choriocapillaris or other microvascular features beneath the retina. We have developed a noninvasive microvascular imaging technique called phase-variance optical coherence tomography (pvOCT), which identifies vasculature three dimensionally through analysis of data acquired with OCT systems. The pvOCT imaging method is not only capable of generating capillary perfusion maps for the retina, but it can also use the 3D capabilities to segment the data in depth to isolate vasculature in different layers of the retina and choroid. This paper demonstrates some of the capabilities of pvOCT imaging of the anterior layers of choroidal vasculature of a healthy normal eye as well as of eyes with geographic atrophy (GA) secondary to age-related macular degeneration. The pvOCT data presented permit digital segmentation to produce 2D depth-resolved images of the retinal vasculature, the choriocapillaris, and the vessels in Sattler’s and Haller’s layers. Comparisons are presented between en face projections of pvOCT data within the superficial choroid and clinical angiography images for regions of GA. Abnormalities and vascular dropout observed within the choriocapillaris for pvOCT are compared with regional GA progression. The capability of pvOCT imaging of the microvasculature of the choriocapillaris and the anterior choroidal vasculature has the potential to become a unique tool to evaluate therapies and understand the underlying mechanisms of age-related macular degeneration progression

    Visualization of human retinal capillary networks: a comparison of intensity, speckle-variance and phase-variance optical coherence tomography

    Get PDF
    We evaluate methods to visualize human retinal micro-circulation in vivo by standard intensity-based optical coherence tomography (OCT), speckle-variance optical coherence tomography (svOCT), and phase-variance optical coherence tomography (pvOCT). En face projection views created from the same volumetric data set of the human retina using all three data processing methods are created and compared. Additionally we used support vector machine (SVM) based semi-automatic segmentation to generate en face projection views of individual retinal layers. The layers include: first, the whole inner retina (from the nerve fiber layer to the outer nuclear layer), and second, from the ganglion cell layer to the outer nuclear layer. Finally, we compare the retinal vasculature images processed from the three OCT techniques and fluorescein angiography (FA)

    Visualization of human retinal micro-capillaries with phase contrast high-speed optical coherence tomography

    Get PDF
    We present high-speed Fourier-domain optical coherence tomography (Fd-OCT) with the phase variance based motion contrast method for visualizing retinal micro-circulation in vivo. This technique allows non-invasive visualization of a two-dimensional retinal perfusion map and concurrent volumetric morphology of retinal microvasculature with high sensitivity. The high-speed acquisition rate at 125kHz A-scans enables reduction of motion artifacts with increased scanning area if compared to previously reported results. Several scanning schemes with different sampling densities and scanning areas are evaluated to find optimal parameters for in vivo imaging. In order to evaluate this technique, we compare OCT micro-capillary imaging using the phase variance technique with fundus fluorescein angiography (FA). Additionally, volumetric visualization of blood flow for a normal subject is presented

    Visualization of human retinal capillary networks: a comparison of intensity, speckle-variance and phase-variance optical coherence tomography

    Get PDF
    We evaluate methods to visualize human retinal micro-circulation in vivo by standard intensity-based optical coherence tomography (OCT), speckle-variance optical coherence tomography (svOCT), and phase-variance optical coherence tomography (pvOCT). En face projection views created from the same volumetric data set of the human retina using all three data processing methods are created and compared. Additionally we used support vector machine (SVM) based semi-automatic segmentation to generate en face projection views of individual retinal layers. The layers include: first, the whole inner retina (from the nerve fiber layer to the outer nuclear layer), and second, from the ganglion cell layer to the outer nuclear layer. Finally, we compare the retinal vasculature images processed from the three OCT techniques and fluorescein angiography (FA)

    Visualization of human retinal and choroidal vascular networks with phase-variance optical coherence tomography

    Get PDF
    We present in vivo noninvasive retinal and choroidal perfusion maps with phase-variance optical coherence tomography (pvOCT). We acquired a pvOCT volumetric data set of a normal subject and visualized blood circulation in the retina and the choroid. En face projection views of the retina as well as the choroid were generated from a manually segmented volumetric data set. In addition, the processed pvOCT images were compared to current standard imaging modalities used for retinal and choroidal vasculature visualization in clinical settings, including fluorescein angiography (FA) and indocyanine green angiography (ICGA)

    Choriocapillaris and Choroidal Microvasculature Imaging with Ultrahigh Speed OCT Angiography

    Get PDF
    We demonstrate in vivo choriocapillaris and choroidal microvasculature imaging in normal human subjects using optical coherence tomography (OCT). An ultrahigh speed swept source OCT prototype at 1060 nm wavelengths with a 400 kHz A-scan rate is developed for three-dimensional ultrahigh speed imaging of the posterior eye. OCT angiography is used to image three-dimensional vascular structure without the need for exogenous fluorophores by detecting erythrocyte motion contrast between OCT intensity cross-sectional images acquired rapidly and repeatedly from the same location on the retina. En face OCT angiograms of the choriocapillaris and choroidal vasculature are visualized by acquiring cross-sectional OCT angiograms volumetrically via raster scanning and segmenting the three-dimensional angiographic data at multiple depths below the retinal pigment epithelium (RPE). Fine microvasculature of the choriocapillaris, as well as tightly packed networks of feeding arterioles and draining venules, can be visualized at different en face depths. Panoramic ultra-wide field stitched OCT angiograms of the choriocapillaris spanning ~32 mm on the retina show distinct vascular structures at different fundus locations. Isolated smaller fields at the central fovea and ~6 mm nasal to the fovea at the depths of the choriocapillaris and Sattler's layer show vasculature structures consistent with established architectural morphology from histological and electron micrograph corrosion casting studies. Choriocapillaris imaging was performed in eight healthy volunteers with OCT angiograms successfully acquired from all subjects. These results demonstrate the feasibility of ultrahigh speed OCT for in vivo dye-free choriocapillaris and choroidal vasculature imaging, in addition to conventional structural imaging.National Institutes of Health (U.S.) (NIH R01-EY011289-27)National Institutes of Health (U.S.) (NIH R01-EY013178-12)National Institutes of Health (U.S.) (NIH R44-EY022864-01)National Institutes of Health (U.S.) (NIH R01-CA075289-16)United States. Air Force Office of Scientific Research (AFOSR FA9550-10-1-0551)United States. Air Force Office of Scientific Research (AFOSR FA9550-12-1-0499
    corecore