11,427 research outputs found

    A result on polynomials derived via graph theory

    Full text link
    We present an example of a result in graph theory that is used to obtain a result in another branch of mathematics. More precisely, we show that the isomorphism of certain directed graphs implies that some trinomials over finite fields have the same number of roots

    XMM Follow-Up Observations of Three Swift BAT-Selected Active Galactic Nuclei

    Full text link
    We present XMM-Newton observations of three AGN taken as part of a hunt to find very heavily obscured Compton-thick AGN. For obscuring columns greater than 10^25 cm^-2, AGN are only visible at energies below 10 keV via reflected/scattered radiation, characterized by a flat power-law. We therefore selected three objects (ESO 417-G006, IRAS 05218-1212, and MCG -01-05-047) from the Swift BAT hard X-ray survey catalog with Swift X-ray Telescope XRT 0.5-10 keV spectra with flat power-law indices as candidate Compton-thick sources for follow-up observations with the more sensitive instruments on XMM-Newton. The XMM spectra, however, rule out reflection-dominated models based on the weakness of the observed Fe K-alpha lines. Instead, the spectra are well-fit by a model of a power-law continuum obscured by a Compton-thin absorber, plus a soft excess. This result is consistent with previous follow-up observations of two other flat-spectrum BAT-detected AGN. Thus, out of the six AGN in the 22-month BAT catalog with apparently flat Swift XRT spectra, all five that have had follow-up observations are not likely Compton-thick. We also present new optical spectra of two of these objects, IRAS 05218-1212 and MCG -01-05-047. Interestingly, though both these AGN have similar X-ray spectra, their optical spectra are completely different, adding evidence against the simplest form of the geometric unified model of AGN. IRAS 05218-1212 appears in the optical as a Seyfert 1, despite the ~8.5x10^22 cm^-2 line-of-sight absorbing column indicated by its X-ray spectrum. MCG -01-05-047's optical spectrum shows no sign of AGN activity; it appears as a normal galaxy.Comment: 18 pages including 4 figures, accepted by Ap

    Patients' preferences for the management of non-metastatic prostate cancer: discrete choice experiment

    Get PDF
    Objective To establish which attributes of conservative treatments for prostate cancer are most important to men. Design Discrete choice experiment. Setting Two London hospitals. Participants 129 men with non-metastatic prostate cancer, mean age 70 years; 69 of 118 (58%) with T stage 1 or 2 cancer at diagnosis. Main outcome measures Men's preferences for, and trade-offs between, the attributes of diarrhoea, hot flushes, ability to maintain an erection, breast swelling or tenderness, physical energy, sex drive, life expectancy, and out of pocket expenses. Results The men's responses to changes in attributes were all statistically significant. When asked to assume a starting life expectancy of five years, the men were willing to make trade-offs between life expectancy and side effects. On average, they were most willing to give up life expectancy to avoid limitations in physical energy (mean three months) and least willing to trade life expectancy to avoid hot flushes (mean 0.6 months to move from a moderate to mild level or from mild to none). Conclusions Men with prostate cancer are willing to participate in a relatively complex exercise that weighs up the advantages and disadvantages of various conservative treatments for their condition. They were willing to trade off some life expectancy to be relieved of the burden of troublesome side effects such as limitations in physical energy

    Encapsulation of a {Cu16} cluster containing four [Cu4O4] cubanes within an isopolyoxometalate {W44} cluster

    Get PDF
    We report a {Cu16} embedded within a {W44} cluster containing four cubane-like [Cu4O4] units within an isopolyoxotungstate (isoPOT) in a {Na4Cu4[(H2W11O38) (CH3COO)(OH)3]}4·88H2O (1) and a polyanion Cu-linked {W11} chain Na6Cu2[(H2W11O38)(CH3COO)(OH)]·26H2O (2). Electronically, the redox properties show that both compounds 1 and 2 undergo irreversible reductions resulting in the demetalation of the compounds, whilst the magnetic behavior of 1 and 2 shows a weak antiferromagnetic and a stronger ferromagnetic coupling, respectively

    On large maximal partial ovoids of the parabolic quadric \q(4,q)

    Full text link
    We use the representation T2(O)T_2(O) for \q(4,q) to show that maximal partial ovoids of \q(4,q) of size q21q^2-1, q=phq=p^h, pp odd prime, h>1h > 1, do not exist. Although this was known before, we give a slightly alternative proof, also resulting in more combinatorial information of the known examples for qq prime.Comment: 11 p

    Quantum Correlation Without Classical Correlations

    Full text link
    We show that genuine multiparty quantum correlations can exist on its own, without a supporting background of genuine multiparty classical correlations, even in macroscopic systems. Such possibilities can have important implications in the physics of quantum information and phase transitions.Comment: 4 pages, no figures; v2: presentation improved, results unchanged, published versio

    Continuous flushing of the bladder in rodents reduces artifacts and improves quantification in molecular imaging

    Get PDF
    In this study, we evaluated the partial volume effect (PVE) of 2-deoxy-2-[18F]fluoro-d-glucose (18F-FDG) tracer accumulation in the bladder on the positron emission tomographic (PET) image quantification in mice and rats suffering from inflammatory bowel disease. To improve the accuracy, we implemented continuous bladder flushing procedures. Female mice and rats were scanned using microPET/computed tomography (CT) at baseline and after induction of acute colitis by injecting 2,4,6-trinitrobenzene sulfonic acid (TNBS) intrarectally. During the scans, the bladder was continuously flushed in one group, whereas in the other group, no bladder flushing was performed. As a means of in vivo and ex vivo validation of the inflammation, animals also underwent colonoscopy and were sacrificed for gamma counting (subpopulation) and to score the colonic damage both micro- and macroscopically as well as biochemically. At baseline, the microPET signal in the colon of both mice and rats was significantly higher in the nonflushed group compared to the flushed group, caused by the PVE of tracer activity in the bladder. Hence, the colonoscopy and postmortem analyses showed no significant differences at baseline between the flushed and nonflushed animals. TNBS induced significant colonic inflammation, as revealed by colonoscopic and postmortem scores, which was not detected by microPET in the mice without bladder flushing, again because of spillover of bladder activity in the colonic area. MicroPET in bladder-flushed animals did reveal a significant increase in 18F-FDG uptake. Correlations between microPET and colonoscopy, macroscopy, microscopy, and myeloperoxidase yielded higher Spearman rho values in mice with continuously flushed bladders during imaging. Comparable, although somewhat less pronounced, results were shown in the rat. Continuous bladder flushing reduced image artifacts and is mandatory for accurate image quantification in the pelvic region for both mice and rats. We designed and validated experimental protocols to facilitate such.Steven Deleye, Marthe Heylen, Annemie Deiteren, Joris De Man, Sigrid Stroobants, Benedicte De Winter, and Steven Staelen

    Unambiguous determination of spin dephasing times in ZnO

    Full text link
    Time-resolved magneto-optics is a well-established optical pump probe technique to generate and to probe spin coherence in semiconductors. By this method, spin dephasing times T_2^* can easily be determined if their values are comparable to the available pump-probe-delays. If T_2^* exceeds the laser repetition time, however, resonant spin amplification (RSA) can equally be used to extract T_2^*. We demonstrate that in ZnO these techniques have several tripping hazards resulting in deceptive values for T_2^* and show how to avoid them. We show that the temperature dependence of the amplitude ratio of two separate spin species can easily be misinterpreted as a strongly temperature dependent T_2^* of a single spin ensemble, while the two spin species have T_2^* values which are nearly independent of temperature. Additionally, consecutive pump pulses can significantly diminish the spin polarization, which remains from previous pump pulses. While this barely affects T_2^* values extracted from delay line scans, it results in seemingly shorter T_2^* values in RSA.Comment: 11 pages, 10 figure
    corecore