19 research outputs found

    Effect of Defocused CO(2 )Laser on Equine Tissue Perfusion

    Get PDF
    Treatment with defocused CO(2 )laser can have a therapeutic effect on equine injuries, but the mechanisms involved are unclear. A recent study has shown that laser causes an increase in equine superficial tissue temperature, which may result in an increase in blood perfusion and a stimulating effect on tissue regeneration. However, no studies have described the effects on equine tissue perfusion. The aim of the present study was to investigate the effect of defocused CO(2 )laser on blood perfusion and to correlate it with temperature in skin and underlying muscle in anaesthetized horses. Differences between clipped and unclipped haircoat were also assessed. Eight horses and two controls received CO(2 )laser treatment (91 J/cm(2)) in a randomised order, on a clipped and unclipped area of the hamstring muscles, respectively. The significant increase in clipped skin perfusion and temperature was on average 146.3 ± 33.4 perfusion units (334%) and 5.5 ± 1.5°C, respectively. The significant increase in perfusion and temperature in unclipped skin were 80.6 ± 20.4 perfusion units (264%) and 4.8 ± 1.4°C. No significant changes were seen in muscle perfusion or temperature. In conclusion, treatment with defocused CO(2 )laser causes a significant increase in skin perfusion, which is correlated to an increase in skin temperature

    Spinal kinematics in horses with induced back pain.

    No full text
    Back problems are important contributors to poor performance in sport horses. It has been shown that kinematic analysis can differentiate horses with back problems from asymptomatic horses. The underlying mechanism can, however, only be identified in a uniform, experimental setting. Our aim was to determine if induction of back pain in a well-defined site would result in a consistent change in back movement. Back kinematics were recorded at a walk and trot on a treadmill. Unilateral back pain was then induced by injecting lactic acid into the left longissimus dorsi muscle. Additional measurements were done subsequent to the injections. Data were captured during steady state locomotion at 240 Hz using an infrared-based gait analysis system. After the injections, the caudal thoracic back was more extended at both gaits. The back was also bent more to the left at both gaits. However, at the walk, there was a reversed pattern after a week with bending of the back to the unaffected side. Horses with identical back injuries appear to show similar changes in their back kinematics, as compared to the asymptomatic condition. Unilateral back pain seems to result in an increased extension of the back, as well as compensatory lateral movements. Back movements are complex and subtle, and changes are difficult to detect with the human eye. Present-day gait analysis systems can identify changes in the back movement, and knowledge of the relationship between such changes and the site of injury will be of help in better localising and diagnosing disorders of the equine back

    Development and evaluation of a noninvasive marker cluster technique to assess three-dimensional kinematics of the distal portion of the forelimb in horses

    No full text
    OBJECTIVE: To develop and evaluate a marker cluster set for measuring sagittal and extrasagittal movement of joints in the distal portion of the forelimb in ponies. ANIMALS: 4 ponies. PROCEDURES: 5 infrared cameras were positioned on a concrete walkway in a frontal-sagittal arc and calibrated. Four segments were defined: hoof, middle phalanx, proximal phalanx, and metacarpus. Rigid clusters with 4 retroreflective markers were placed on each segment. A static trial was recorded with additional anatomic markers on the medial and lateral joint lines. Those anatomic markers were removed, and kinematic data were recorded at 240 Hz during walking. An ensemble mean was computed from the 4 ponies from 5 replicates of the walks. Joint kinematic variables were calculated by use of the calibrated anatomical system technique. The design and error dispersion of each marker were evaluated. RESULTS: Marker clusters were quasiplanar, but variation in orientation error was reduced because the mean radii were > 10 times the largest error dispersion values. Measurements of sagittal rotations of the distal interphalangeal, proximal interphalangeal, and metacarpophalangeal joints were similar to measurements obtained with bone-fixed triads, but larger discrepancies between the 2 methods were found for extrasagittal rotations. CONCLUSIONS AND CLINICAL RELEVANCE: Development of noninvasive methods for quantifying data pertaining to 3-dimensional motion in horses is important for advancement of clinical analysis. The technique used in the study enabled identification of flexion-extension motions with an acceptable degree of accuracy. Appropriate correction algorithms and improvements to the technique may enable future quantification of extrasagittal motions
    corecore