405 research outputs found

    LIBS experiments for quantitative detection of retained fuel

    Get PDF
    Abstract Laser Induced Breakdown Spectroscopy (LIBS) provides chemical information from atomic and ionic plasma emissions generated by laser vaporization of a sample. At the ENEA research center, in collaboration with IPPLM, an equipment has been set up to qualitatively and quantitatively determine the chemical composition of impurities deposited on Plasma Facing Components (PFC). The strength of the LIBS, for its capability of light elements detection, is fully exploited to determine the deuterium content since this element can be considered as the best choice proxy for tritium; the latter being is of great importance in assessing safe conditions to assure the continuous operation in nuclear fusion tokamak. Here we present the results of the Double Pulse LIBS (DP-LIBS) probing of deuterated samples with the simultaneous optical detection by medium-resolution and high-resolution spectrometer. Deuterium emission at 656.1 nm has been detected then the elemental composition has been quantified by applying the Calibration Free (CF) approach. The obtained results demonstrate that the DP-LIBS technique combined with CF analysis is suitable for the quantitative determination of tritium content inside the PFCs of next fusion devices like ITER

    Detection by LIBS of the deuterium retained in the FTU toroidal limiter

    Get PDF
    In this paper the Laser Induced Breakdown Spectroscopy (LIBS) measurement of the deuterium (used as a proxy for tritium) retained in and the surface elemental composition of the FTU Mo (TZM) toroidal limiter tiles, carried out from remote (∼2.5 m) during short breaks of the operations or during machine maintenance, are reported. Single pulse technique has been used with the FTU vessel under high vacuum or in Nitrogen or Argon atmosphere. In vacuum experiments Dα and Hα lines have been detected with good resolution, while in Ar atmosphere (5 × 104 Pa) the two lines were partially overlapped due to Stark broadening. First results of measurements in N2 atmosphere (105 Pa) showed no presence of Dα and Hα lines. These measurements were also carried out for supporting the foreseen use of a robotic arm for an extended LIBS analysis of retained deuterium in the FTU vessel components. Keywords: LIBS, FTU tokamak, Toroidal limiter, Deuterium retentio

    Development of On-Line Tritium Monitor Based Upon Artificial Diamond for Fusion Applications

    Get PDF
    In this paper a novel on-line tritium monitor is presented. It is made with a single crystal diamond detector (SCD) covered with a thin layer of LiF 95% enriched in <sup>6</sup>Li. Thermal neutrons impinging on the LiF layer produce α and T ions which are detected by the active diamond. The pulse height spectrum shows two separated peaks due to α and T ions respectively. By a proper calibration in a reference thermal flux the number of <sup>6</sup>Li atoms and thus the absolute n+<sup>6</sup>Li→α+T reaction rate per unitary flux can be established. Once calibrated the detector can be used to measure the tritium production. Due to the many outstanding properties of diamond this detector could operate in the harsh working conditions of a fusion breeding blanket. A test of this detector was performed at the 14 MeV Frascati Neutron Generator (FNG). The detector was inserted inside a mock-up of the European Helium Cooled Lithium Lead (HCLL) Tritium Blanket Module (TBM), designed to validate the neutronic database for fusion application. The mock-up of the TBM was designed to perform a full set of experiments to validate tritium production code prediction comparing the experimental results with calculations. The measured tritium rates with the Li-Diamond detector are described in this paper. Comparison with calculations is in progress and will be reported in a future paper

    Thermal and fast neutron detection in chemical vapor deposition single-crystal diamond detectors

    Get PDF
    Recently, a compact solid-state neutron detector capable of simultaneously detecting thermal and fast neutrons was proposed [M. Marinelli et al., Appl. Phys. Lett. 89, 143509 (2006)]. Its design is based on a p-type/intrinsic/metal layered structure obtained by Microwave Plasma Chemical Vapor Deposition (CVD) of homoepitaxial diamond followed by thermal evaporation of an Al contact and a <sup>6</sup>LiF converting layer. Fast neutrons are directly detected in the CVD diamond bulk, since they have enough energy to produce the <sup>12</sup>C(n, α)<sup>9</sup>Be reaction in diamond. Thermal neutrons are instead converted into charged particles in the <sup>6</sup>LiF layer through the <sup>6</sup>Li(n, α)T nuclear reaction. These charged particles are then detected in the diamond layer. The thickness of the <sup>6</sup>LiF converting layer and the CVD diamond sensing layer affect the counting efficiency and energy resolution of the detector both for low- (thermal) and high-energy neutrons. An analysis is carried out on the dynamics of the <sup>6</sup>Li(n, α)T and the <sup>12</sup>C(n, α)<sup>9</sup>Be reactions products, and the distribution of the energy released inside the sensitive layer is calculated. The detector counting efficiency and energy resolution were accordingly derived as a function of the thickness of the <sup>6</sup>LiF and CVD diamond layers, both for thermal and fast neutrons, thus allowing us to choose the optimum detector design for any particular application. Comparison with experimental results is also reported

    Contact X-ray microscopy of living cells by using LiF crystal as imaging detector

    Get PDF
    In this paper, the use of lithium fluoride (LiF) as imaging radiation detector to analyse living cells by single-shot soft X-ray contact microscopy is presented. High resolved X-ray images on LiF of cyanobacterium Leptolyngbya VRUC135, two unicellular microalgae of the genus Chlamydomonas and mouse macrophage cells (line RAW 264.7) have been obtained utilizingX-ray radiation in the water window energy range from a laser plasma source. The used method is based on loading of the samples, the cell suspension, in a special holder where they are in close contactwith a LiF crystal solid-state Xray imaging detector. After exposure and sample removal, the images stored in LiF by the softX-ray contactmicroscopy technique are read by an optical microscope in fluorescence mode. The clear image of the mucilaginous sheath the structure of the filamentous Leptolyngbya and the visible nucleolus in the macrophage cells image, are noteworthiness results. The peculiarities of the used X-ray radiation and of the LiF imaging detector allow obtaining images in absorption contrast revealing the internal structures of the investigated samples at high spatial resolution. Moreover, thewidedynamicrangeof theLiF imaging detector contributes to obtain high-quality images. In particular, we demonstrate that this peculiar characteristic of LiF detector allows enhancing the contrast and reveal details even when they were obscured by a nonuniform stray light

    Characterization of damage induced by heavy neutron irradiation on multilayered 6LiF-single crystal chemical vapor deposition diamond detectors

    Get PDF
    High performance neutron detectors sensitive to both thermal and fast neutrons are of great interest to monitor the high neutron flux produced, e.g., by fission and fusion reactors. An obvious requirement for such an application is neutron irradiation hardness. This is why diamond based neutron detectors are currently under test in some of these facilities. In this paper the damaging effects induced in chemical vapor deposition (CVD) diamond based detectors by a neutron fluence of ~2 × 10<sup>16</sup> neutrons/cm<sup>2</sup> have been studied and significant changes in spectroscopic, electrical, and optical properties have been observed. The detectors are fabricated using high quality synthetic CVD single crystal diamond using the p-type/intrinsic/Schottky metal/<sup>6</sup>LiF layered structure recently proposed by Marinelli et al [Appl. Phys. Lett. 89, 143509 (2006)], which allows simultaneous detection of thermal and fast neutrons. Neutron radiation hardness up to at least 2 × 10<sup>14</sup> n/cm<sup>2</sup> fast (14 MeV) neutron fluence has been confirmed so far [see Pillon et al, Fusion Eng. Des. 82, 1174 (2007)]. However, at the much higher neutron fluence of ~2 × 10<sup>16</sup> neutrons/cm<sup>2</sup> damage is observed. The detector response to 5.5 MeV <sup>241</sup>Am α-particles still shows a well resolved α-peak, thus confirming the good radiation hardness of the device but a remarkable degradation and a significant instability with time of charge collection efficiency and energy resolution arise. Symmetric, nearly Ohmic I-V (current-voltage) characteristics have been recorded from the metal/intrinsic/p-doped diamond layered structure, which before neutron irradiation acted as a Schottky barrier diode with a strong rectifying behavior. The nature and the distribution of the radiation induced damage have been deeply examined by means of cathodoluminescence spectroscopy. A more heavily damaged area into the intrinsic diamond at the same position and with the same extension of the <sup>6</sup>LiF layer has been found, the increased damage being ascribed to the highly ionizing particles produced in the <sup>6</sup>LiF layer by thermal neutrons through the nuclear reaction <sup>6</sup>Li(n, α)T

    Neutron Detectors Based Upon Artificial Single Crystal Diamond

    Get PDF
    This paper reports about state-of-the-art artificial Single Crystal Diamond (SCD) neutron detectors based on a multilayered structure and grown by chemical vapour deposition (CVD) technique. Multilayered SCD detectors covered with a thin layer of 6LiF allow the simultaneous detection of both slow and fast neutrons and can operate in pulse and current mode. These detectors can also be produced with a thin layer of Boron. Application of SCD detectors to neutron detection around fusion tokamak is reported. Some problems related to the processing of the very fast electrical pulse produced by diamond are addressed and the achieved and foreseen development of the processing electronics is reported as well

    Plasma–wall interaction studies within the EUROfusion consortium : progress on plasma-facing components development and qualification

    Get PDF
    The provision of a particle and power exhaust solution which is compatible with first-wall components and edge-plasma conditions is a key area of present-day fusion research and mandatory for a successful o peration of ITER and DEMO. The work package plasma-facing components (WP PFC) within the European fusion programme complements with laboratory experiments, i.e. in linear plasma devices, electron and ion beam loading f acilities, the studies performed in toroidally confined magnetic devices, such as JET, ASDEX Upgrade, WEST etc. The connection of both groups is done via common physics and engineering studies, including the qualificat ion and specification of plasma-facing components, and by modelling codes that simulate edge-plasma conditions and the plasma–material interaction as well as the study of fundamental processes. WP PFC addresses these c ritical points in order to ensure reliable and efficient use of conventional, solid PFCs in ITER (Be and W) and DEMO (W and steel) with respect to heat-load capabilities (transient and steady-state heat and particle lo ads), lifetime estimates (erosion, material mixing and surface morphology), and safety aspects (fuel retention, fuel removal, material migration and dust formation) particularly for quasi-steady-state conditions. Alter native scenarios and concepts (liquid Sn or Li as PFCs) for DEMO are developed and tested in the event that the conventional solution turns out to not be functional. Here, we present an overview of the activities with an emphasis on a few key results: (i) the observed synergistic effects in particle and heat loading of ITER-grade W with the available set of exposition devices on material properties such as roughness, ductility and m icrostructure; (ii) the progress in understanding of fuel retention, diffusion and outgassing in different W-based materials, including the impact of damage and impurities like N; and (iii), the preferential sputtering of Fe in EUROFER steel providing an in situ W surface and a potential first-wall solution for DEMO.Peer reviewe

    x ray imaging of bio medical samples using laser plasma based x ray sources and lif detector

    Get PDF
    This contribution to ECPD2019 is dedicated to the memory of Anatoly Faenov. During a period of approximately thirteen years 1994–2006, Anatoly and his wife Tatiana Pikuz (simply "Tania" for friends), accepting the frequent invitations of the National Institute for Nuclear Physics (INFN) and of the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), cooperated with many Italian research laboratories dedicated to EUV and soft X-ray generation, spread in different towns (L'Aquila, Frascati, Milano, Padova, Pisa, Roma, etc.). In spite of the fact that they could stay in Italy only about one or two months per year, their activity was so intense that more than 50 peer- reviewed publications were generated from their experimental and theoretical work (just considering only the results obtained at L'Aquila and Tor Vergata—Rome Universities and at the ENEA Research Center of Frascati), without mentioning the cultural atmosphere that they stimulated in the field of Science and Humanity. The numerous experimental spectra obtained at ENEA by means of their spherically bent mica spectrometers, together with the corresponding theoretical simulations performed in Moscow, allowed to study the changing role of different excitations mechanisms for various plasma conditions, and to characterize at best the ENEA laser-plasma source for different applications: polychromatic and monochromatic micro-radiography of dried biological samples at 1 keV, soft X-ray contact microscopy (SXCM) of living cells in the water-window spectral region, spectroscopy of hollow atoms, etc. In this memorial paper, the main results of biological samples imaging on lithium fluoride (LiF) detectors, obtained with the ENEA and Tor Vergata University laser-plasma sources, are presented. In particular, the improvement of the micro-radiography and of the SXCM techniques obtained after moving from photoresist detectors and photographic films to lithium fluoride (LiF) detectors are discussed, for both dried and wet biological samples

    Overview of the FTU results

    Get PDF
    Since the 2018 IAEA FEC Conference, FTU operations have been devoted to several experiments covering a large range of topics, from the investigation of the behaviour of a liquid tin limiter to the runaway electrons mitigation and control and to the stabilization of tearing modes by electron cyclotron heating and by pellet injection. Other experiments have involved the spectroscopy of heavy metal ions, the electron density peaking in helium doped plasmas, the electron cyclotron assisted start-up and the electron temperature measurements in high temperature plasmas. The effectiveness of the laser induced breakdown spectroscopy system has been demonstrated and the new capabilities of the runaway electron imaging spectrometry system for in-flight runaways studies have been explored. Finally, a high resolution saddle coil array for MHD analysis and UV and SXR diamond detectors have been successfully tested on different plasma scenarios
    • …
    corecore