25 research outputs found
E-Pulse, 2010-04
An online news publication of the College of Health and Human Services at Governors State University
METROLOGICAL SUPPORT OF DOSIMETRY GAMMA-RAY WITH ENERGY TO 10 MEV FOR RADIATION PROTECTION DEVICES
The field of high-energy gamma-ray for the calibration of radiation protection devices can be obtained by capturing thermal neutrons from titanium target (to 7 MeV) and nickel target (to 10 MeV). The aim of this work was to determine the metrological characteristics of capture gamma-ray fields from titanium target and nickel target obtained at the AT140 Neutron Calibration Facility to provide dosimetry up to 10 MeV.We have chosen energy intervals in which we can calibrate dosimetry devices taking into account the accompanying generation of gamma-ray neutrons by the fast neutron source 238PuBe, the capture radiation of collimator materials and capture radiation from targets.We measured air kerma rate with the aid of the reference AT5350 dosimeter with the ionization chamber TM32002. Using the Monte-Carlo simulation, we obtained the energy distribution of the air kerma rate for targets. We determined the geometric dimensions of the uniform field and the interval of operating distances of the facility.We investigated the metrological characteristics of capture gamma-ray fields from titanium target and nickel target obtained at the AT140 Neutron Calibration Facility for dosimetric radiation protection devices. We showed that in such fields it is possible to calibrate dosimetry devices in the extended energy range up to 10 MeV
ΠΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΠ΅ ΡΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΡ 238U ΠΏΠΎ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ 234mPa
Radionuclide 238U is one of the most important radioactive elements that must be controlled in nuclear power engineering, geological exploration, control of radioactive contamination of soils and raw materials used in construction. The most optimal way to control 238U is to use the 234mPa radionuclide, the activity of which, due to its short lifetime (β 1.2 min), is unambiguously related to the activity of 238U even if the secular equilibrium is disturbed in the sample under studyΠ ossibility of use of the 234mPa nuclide gamma radiation to determine 238U with a scintillation detector in a medium containing natural radionuclides is investigated and demonstrated using the simplest examples. The proposed algorithm for determining of the 238U content is based on the Monte Carlo simulation of the detector response to the radiation of the 234mPa radionuclide at its 1001 keV energy line and subsequent processing of the experimental spectrum, including the Wiener filtering of the signal. This method makes it possible to determine the content of 238U in a continuous homogeneous medium while presence of natural radionuclides in it.The algorithm for determining of 238U content includes several main steps. Filtering based on the Wiener algorithm allows selecting a slowly changing part of the spectrum. Results of Monte Carlo simulations make it possible to determine the detection efficiency in a limited informative region of the spectrum, which includes, along with the 1001 keV peak from the 234mPa nuclide, which is a decay product of the radionuclide 234Th, and the peak of an interfering radionuclide from the decay chain of 232Th. This part of the spectrum does not contain any other lines of gamma radiation from natural radionuclides β decay products of both thorium and uranium chains. These two peaks in the spectral region under study can be separated from each other in a medium with a typical concentration of 234Th.Analysis of results of the activity of depleted uranium metal measuring in accordance with the proposed algorithm shows the possibility of determining of 238U content with an uncertainty of 3β5 %.Π Π°ΡΠΎΠΌΠ½ΠΎΠΉ ΡΠ½Π΅ΡΠ³Π΅ΡΠΈΠΊΠ΅, Π² Π³Π΅ΠΎΠ»ΠΎΠ³ΠΎΡΠ°Π·Π²Π΅Π΄ΠΊΠ΅, ΠΏΡΠΈ ΠΊΠΎΠ½ΡΡΠΎΠ»Π΅ ΡΠ°Π΄ΠΈΠΎΠ°ΠΊΡΠΈΠ²Π½ΠΎΠ³ΠΎ Π·Π°Π³ΡΡΠ·Π½Π΅Π½ΠΈΡ ΠΏΠΎΡΠ² ΠΈ ΡΡΡΡΡ, ΠΈΡΠΏΠΎΠ»ΡΠ·ΡΠ΅ΠΌΠΎΠ³ΠΎ ΠΏΡΠΈ ΡΡΡΠΎΠΈΡΠ΅Π»ΡΡΡΠ²Π΅, ΠΎΠ΄Π½ΠΈΠΌ ΠΈΠ· Π²Π°ΠΆΠ½Π΅ΠΉΡΠΈΡ
ΡΠ°Π΄ΠΈΠΎΠ°ΠΊΡΠΈΠ²Π½ΡΡ
ΡΠ»Π΅ΠΌΠ΅Π½ΡΠΎΠ², ΠΊΠΎΡΠΎΡΡΠΉ Π½Π΅ΠΎΠ±Ρ
ΠΎΠ΄ΠΈΠΌΠΎ ΠΊΠΎΠ½ΡΡΠΎΠ»ΠΈΡΠΎΠ²Π°ΡΡ, ΡΠ²Π»ΡΠ΅ΡΡΡ 238U. ΠΠ°ΠΈΠ±ΠΎΠ»Π΅Π΅ ΠΎΠΏΡΠΈΠΌΠ°Π»ΡΠ½ΠΎ Π΄Π»Ρ ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ 238U ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°ΡΡ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄ 234mPa, Π°ΠΊΡΠΈΠ²Π½ΠΎΡΡΡ ΠΊΠΎΡΠΎΡΠΎΠ³ΠΎ ΠΈΠ·-Π·Π° ΠΌΠ°Π»ΠΎΡΡΠΈ Π²ΡΠ΅ΠΌΠ΅Π½ΠΈ Π΅Π³ΠΎ ΠΆΠΈΠ·Π½ΠΈ (β 1,2 ΠΌΠΈΠ½) ΠΎΠ΄Π½ΠΎΠ·Π½Π°ΡΠ½ΠΎ ΡΠ²ΡΠ·Π°Π½Π° Ρ Π°ΠΊΡΠΈΠ²Π½ΠΎΡΡΡΡ 238U Π΄Π°ΠΆΠ΅ ΠΏΡΠΈ ΡΡΠ»ΠΎΠ²ΠΈΠΈ Π½Π°ΡΡΡΠ΅Π½ΠΈΡ Π²Π΅ΠΊΠΎΠ²ΠΎΠ³ΠΎ ΡΠ°Π²Π½ΠΎΠ²Π΅ΡΠΈΡ Π² ΠΈΡΡΠ»Π΅Π΄ΡΠ΅ΠΌΠΎΠΌ ΠΎΠ±ΡΠ°Π·ΡΠ΅. ΠΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½Π° ΠΈ ΠΏΡΠΎΠ΄Π΅ΠΌΠΎΠ½ΡΡΡΠΈΡΠΎΠ²Π°Π½Π° Π½Π° ΠΏΡΠΎΡΡΠ΅ΠΉΡΠΈΡ
ΠΏΡΠΈΠΌΠ΅ΡΠ°Ρ
Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΡ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΡ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π½ΡΠΊΠ»ΠΈΠ΄Π° 234mPa Π΄Π»Ρ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ 238U Ρ ΠΏΠΎΠΌΠΎΡΡΡ ΡΡΠΈΠ½ΡΠΈΠ»Π»ΡΡΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ Π΄Π΅ΡΠ΅ΠΊΡΠΎΡΠ° Π² ΡΡΠ΅Π΄Π΅, ΡΠΎΠ΄Π΅ΡΠΆΠ°ΡΠ΅ΠΉ Π΅ΡΡΠ΅ΡΡΠ²Π΅Π½Π½ΡΠ΅ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Ρ. ΠΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½Π½ΡΠΉ Π°Π»Π³ΠΎΡΠΈΡΠΌ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΡΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΡ 238U ΠΎΡΠ½ΠΎΠ²Π°Π½ Π½Π° ΠΌΠΎΠ΄Π΅Π»ΠΈΡΠΎΠ²Π°Π½ΠΈΠΈ ΠΌΠ΅ΡΠΎΠ΄ΠΎΠΌ ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ ΠΎΡΠΊΠ»ΠΈΠΊΠ° Π΄Π΅ΡΠ΅ΠΊΡΠΎΡΠ° Π½Π° ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΠ΅ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π° 234mPa Π½Π° Π΅Π³ΠΎ ΠΌΠΎΠ½ΠΎΠ»ΠΈΠ½ΠΈΠΈ 1001 ΠΊΡΠ ΠΈ ΠΏΠΎΡΠ»Π΅Π΄ΡΡΡΠ΅ΠΉ ΠΎΠ±ΡΠ°Π±ΠΎΡΠΊΠ΅ ΡΠΊΡΠΏΠ΅ΡΠΈΠΌΠ΅Π½ΡΠ°Π»ΡΠ½ΠΎΠ³ΠΎ ΡΠΏΠ΅ΠΊΡΡΠ° ΠΏΡΠΈΠ±ΠΎΡΠ°, Π²ΠΊΠ»ΡΡΠ°ΡΡΠ΅ΠΉ Π²ΠΈΠ½Π΅ΡΠΎΠ²ΡΠΊΡΡ ΡΠΈΠ»ΡΡΡΠ°ΡΠΈΡ ΡΠΈΠ³Π½Π°Π»Π°. ΠΡΠΎΡ ΡΠΏΠΎΡΠΎΠ± ΠΏΠΎΠ·Π²ΠΎΠ»ΡΠ΅Ρ ΠΎΠΏΡΠ΅Π΄Π΅Π»ΠΈΡΡ ΡΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ 238U Π² ΡΠΏΠ»ΠΎΡΠ½ΠΎΠΉ ΠΎΠ΄Π½ΠΎΡΠΎΠ΄Π½ΠΎΠΉ ΡΡΠ΅Π΄Π΅ ΠΏΡΠΈ Π½Π°Π»ΠΈΡΠΈΠΈ Π² Π½Π΅ΠΉ Π΅ΡΡΠ΅ΡΡΠ²Π΅Π½Π½ΡΡ
ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄ΠΎΠ². ΠΠ»Π³ΠΎΡΠΈΡΠΌ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΡΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΡ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π° Π²ΠΊΠ»ΡΡΠ°Π΅Ρ Π² ΡΠ΅Π±Ρ Π½Π΅ΡΠΊΠΎΠ»ΡΠΊΠΎ ΠΎΡΠ½ΠΎΠ²Π½ΡΡ
ΡΡΠ°ΠΏΠΎΠ².Π€ΠΈΠ»ΡΡΡΠ°ΡΠΈΡ Π½Π° ΠΎΡΠ½ΠΎΠ²Π΅ Π°Π»Π³ΠΎΡΠΈΡΠΌΠ° ΠΠΈΠ½Π΅ΡΠ° ΠΏΠΎΠ·Π²ΠΎΠ»ΡΠ΅Ρ Π²ΡΠ΄Π΅Π»ΠΈΡΡ ΠΌΠ΅Π΄Π»Π΅Π½Π½ΠΎ ΠΌΠ΅Π½ΡΡΡΡΡΡΡ ΡΠ°ΡΡΡ ΡΠΏΠ΅ΠΊΡΡΠ°. Π Π΅Π·ΡΠ»ΡΡΠ°ΡΡ ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ ΠΌΠΎΠ΄Π΅Π»ΠΈΡΠΎΠ²Π°Π½ΠΈΡ Π΄Π°ΡΡ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΡ ΠΎΠΏΡΠ΅Π΄Π΅Π»ΠΈΡΡ ΡΡΡΠ΅ΠΊΡΠΈΠ²Π½ΠΎΡΡΡ ΡΠ΅Π³ΠΈΡΡΡΠ°ΡΠΈΠΈ Π² ΠΎΠ³ΡΠ°Π½ΠΈΡΠ΅Π½Π½ΠΎΠΌ ΠΈΠ½ΡΠΎΡΠΌΠ°ΡΠΈΠ²Π½ΠΎΠΌ ΡΡΠ°ΡΡΠΊΠ΅ ΡΠΏΠ΅ΠΊΡΡΠ°, Π²ΠΊΠ»ΡΡΠ°ΡΡΠ΅ΠΌ Π½Π°ΡΡΠ΄Ρ Ρ ΠΏΠΈΠΊΠΎΠΌ 1001 ΠΊΡΠ ΠΎΡ Π½ΡΠΊΠ»ΠΈΠ΄Π° 234mPa, ΡΠ²Π»ΡΡΡΠ΅Π³ΠΎΡΡ ΠΏΡΠΎΠ΄ΡΠΊΡΠΎΠΌ ΡΠ°ΡΠΏΠ°Π΄Π° ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π° 234Th, ΠΈ Π±Π»ΠΈΠΆΠ°ΠΉΡΠΈΠΉ ΠΊ Π½Π΅ΠΌΡ ΠΏΠΈΠΊ ΠΌΠ΅ΡΠ°ΡΡΠ΅Π³ΠΎ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π° ΠΈΠ· ΡΠ΅ΠΏΠΎΡΠΊΠΈ ΡΠ°ΡΠΏΠ°Π΄Π° 232Th. ΠΡΠΎΡ ΡΡΠ°ΡΡΠΎΠΊ ΡΠΏΠ΅ΠΊΡΡΠ° ΠΏΠΎ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Π½Π΅ ΡΠΎΠ΄Π΅ΡΠΆΠΈΡ Π½ΠΈΠΊΠ°ΠΊΠΈΡ
Π΄ΡΡΠ³ΠΈΡ
Π»ΠΈΠ½ΠΈΠΈ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΎΡ Π΅ΡΡΠ΅ΡΡΠ²Π΅Π½Π½ΡΡ
ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄ΠΎΠ² β ΠΏΡΠΎΠ΄ΡΠΊΡΠΎΠ² ΡΠ°ΡΠΏΠ°Π΄Π° ΠΊΠ°ΠΊ ΡΠΎΡΠΈΠ΅Π²ΠΎΠΉ, ΡΠ°ΠΊ ΠΈ ΡΡΠ°Π½ΠΎΠ²ΡΡ
ΡΠ΅ΠΏΠΎΡΠ΅ΠΊ. Π£ΠΊΠ°Π·Π°Π½Π½ΡΠ΅ Π΄Π²Π° ΠΏΠΈΠΊΠ° Π½Π° ΠΈΡΡΠ»Π΅Π΄ΡΠ΅ΠΌΠΎΠΌ ΡΡΠ°ΡΡΠΊΠ΅ ΡΠΏΠ΅ΠΊΡΡΠ° ΠΌΠΎΠ³ΡΡ Π±ΡΡΡ ΠΎΡΠ΄Π΅Π»Π΅Π½Ρ Π΄ΡΡΠ³ ΠΎΡ Π΄ΡΡΠ³Π° Π² ΡΡΠ΅Π΄Π΅ Ρ ΡΠΈΠΏΠΈΡΠ½ΠΎΠΉ ΠΊΠΎΠ½ΡΠ΅Π½ΡΡΠ°ΡΠΈΠ΅ΠΉ 234Th.ΠΠ½Π°Π»ΠΈΠ· ΡΠ΅Π·ΡΠ»ΡΡΠ°ΡΠΎΠ² ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΡ Π°ΠΊΡΠΈΠ²Π½ΠΎΡΡΠΈ ΠΎΠ±Π΅Π΄Π½ΡΠ½Π½ΠΎΠ³ΠΎ ΠΌΠ΅ΡΠ°Π»Π»ΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΡΡΠ°Π½Π° Π² ΡΠΎΠΎΡΠ²Π΅ΡΡΡΠ²ΠΈΠΈ Ρ ΠΏΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½Π½ΡΠΌ Π°Π»Π³ΠΎΡΠΈΡΠΌΠΎΠΌ ΠΏΠΎΠΊΠ°Π·ΡΠ²Π°Π΅Ρ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΡ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΡΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΡ 238U Ρ ΠΏΠΎΠ³ΡΠ΅ΡΠ½ΠΎΡΡΡΡ 3β5 %
ΠΠΠΠ―ΠΠΠ Π ΠΠ‘Π‘ΠΠ―ΠΠΠΠΠ ΠΠΠΠ’Π ΠΠΠΠΠΠ ΠΠΠΠ£Π§ΠΠΠΠ― ΠΠ ΠΠΠ’Π ΠΠΠΠΠΠ§ΠΠ‘ΠΠΠ Π₯ΠΠ ΠΠΠ’ΠΠ ΠΠ‘Π’ΠΠΠ ΠΠΠΠΠ ΠΠ§ΠΠΠ Π£Π‘Π’ΠΠΠΠΠΠ ΠΠΠΠ’Π ΠΠΠΠΠΠ ΠΠΠΠ£Π§ΠΠΠΠ― Π£ΠΠ-ΠΠ’140
Today facilities with collimated radiation field are widely used as reference in metrological support of devices for neutron radiation measurement. Neutron fields formed by radionuclide neutron sources. The aim of this research was to study characteristics of experimentally realized neutron fields geometries on ΠΠ’140 Neutron Calibration Facility using Monte Carlo method.For calibration, we put a device into neutron field with known flux density or ambient equivalent dose rate. We can form neutron beam from radionuclide fast-neutron source in different geometries. In containercollimator of ΠΠ’140 Neutron Calibration Facility we can install special inserts to gather fast-neutron geometry or thermal-neutron geometry. We need to consider neutron scattering from air and roomβs walls. We can conduct measurements of neutron field characteristics in several points and get the other using Monte Carlo method.Thermal neutron collimator forms a beam from radionuclide source with a significant amount of neutrons with thermal energies. From found relationship between full neutron flux and distance to neutron source we see that inverse square law is violated. Scattered radiation contribution into total flux increases when we are moving away from neutron source and significantly influences neutron fields characteristics. While source is exposed in shadow-cone geometry neutron specter has pronounced thermal component from wall scattering.In this work, we examined main geometry types used to acquire reference neutron radiation using radionuclide sources. We developed Monte Carlo model for 238Pu-Be neutron source and ΠΠ’140 Neutron Calibration Facilityβs container-collimator. We have shown the most significant neutron energy distribution factor to be scattered radiation from roomβs walls. It leads to significant changes of neutron radiation specter at a distance from the source. When planning location, and installing the facility we should consider radiation quality requirements.Β Π ΠΌΠ΅ΡΡΠΎΠ»ΠΎΠ³ΠΈΡΠ΅ΡΠΊΠΎΠΌ ΠΎΠ±Π΅ΡΠΏΠ΅ΡΠ΅Π½ΠΈΠΈ ΡΡΠ΅Π΄ΡΡΠ² ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΠΉ Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π² ΠΊΠ°ΡΠ΅ΡΡΠ²Π΅ ΡΡΠ°Π»ΠΎΠ½ΠΎΠ² ΡΠΈΡΠΎΠΊΠΎΠ΅ ΡΠ°ΡΠΏΡΠΎΡΡΡΠ°Π½Π΅Π½ΠΈΠ΅ ΠΏΠΎΠ»ΡΡΠΈΠ»ΠΈ ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ Ρ ΠΊΠΎΠ»Π»ΠΈΠΌΠΈΡΠΎΠ²Π°Π½Π½ΡΠΌ ΠΏΠΎΠ»Π΅ΠΌ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ, ΡΠΎΠ·Π΄Π°Π²Π°Π΅ΠΌΡΠΌ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π½ΡΠΌΠΈ ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ°ΠΌΠΈ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ². Π¦Π΅Π»ΡΡ Π΄Π°Π½Π½ΠΎΠΉ ΡΠ°Π±ΠΎΡΡ ΡΠ²Π»ΡΠ»ΠΎΡΡ ΠΈΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΠ΅ Π²Π»ΠΈΡΠ½ΠΈΡ ΡΠ°ΡΡΠ΅ΡΠ½Π½ΠΎΠ³ΠΎ Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π½Π° ΡΠ°ΠΊΠΈΠ΅ ΠΌΠ΅ΡΡΠΎΠ»ΠΎΠ³ΠΈΡΠ΅ΡΠΊΠΈΠ΅ Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠΈΡΡΠΈΠΊΠΈ ΠΏΠΎΠ²Π΅ΡΠΎΡΠ½ΠΎΠΉ ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π£ΠΠ-ΠΠ’140, ΠΊΠ°ΠΊ ΠΏΠ»ΠΎΡΠ½ΠΎΡΡΡ ΠΏΠΎΡΠΎΠΊΠ° ΠΈ Π°ΠΌΠ±ΠΈΠ΅Π½ΡΠ½ΡΠΉ ΡΠΊΠ²ΠΈΠ²Π°Π»Π΅Π½Ρ ΠΌΠΎΡΠ½ΠΎΡΡΠΈ Π΄ΠΎΠ·Ρ Ρ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ ΠΌΠ΅ΡΠΎΠ΄Π° ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ.ΠΡΠΈ ΠΊΠ°Π»ΠΈΠ±ΡΠΎΠ²ΠΊΠ΅ ΠΈΡΠΏΡΡΡΠ΅ΠΌΡΠΉ ΠΏΡΠΈΠ±ΠΎΡ ΠΏΠΎΠΌΠ΅ΡΠ°ΡΡ Π² Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ΅ ΠΏΠΎΠ»Π΅ Ρ ΠΈΠ·Π²Π΅ΡΡΠ½ΠΎΠΉ ΠΏΠ»ΠΎΡΠ½ΠΎΡΡΡΡ ΠΏΠΎΡΠΎΠΊΠ° ΠΈΠ»ΠΈ Π°ΠΌΠ±ΠΈΠ΅Π½ΡΠ½ΡΠΌ ΡΠΊΠ²ΠΈΠ²Π°Π»Π΅Π½ΡΠΎΠΌ ΠΌΠΎΡΠ½ΠΎΡΡΠΈ Π΄ΠΎΠ·Ρ. ΠΡΡΠΎΠΊ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΎΡ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π½ΠΎΠ³ΠΎ ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ° Π±ΡΡΡΡΡΡ
Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΌΠΎΠΆΠ΅Ρ Π±ΡΡΡ ΡΡΠΎΡΠΌΠΈΡΠΎΠ²Π°Π½ Π² ΡΠ°Π·Π»ΠΈΡΠ½ΡΡ
Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΡΡ
. Π ΠΊΠΎΠ½ΡΠ΅ΠΉΠ½Π΅ΡΠ΅-ΠΊΠΎΠ»Π»ΠΈΠΌΠ°ΡΠΎΡΠ΅ ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ ΠΏΠΎΠ²Π΅ΡΠΎΡΠ½ΠΎΠΉ Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π£ΠΠ-ΠΠ’140 ΡΡΡΠ°Π½Π°Π²Π»ΠΈΠ²Π°ΡΡΡΡ ΡΠΏΠ΅ΡΠΈΠ°Π»ΡΠ½ΡΠ΅ Π²ΡΡΠ°Π²ΠΊΠΈ, ΠΎΡΠ²Π΅ΡΠ°ΡΡΠΈΠ΅ Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΠΈ Π±ΡΡΡΡΡΡ
ΠΈ Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΠΈ ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ
Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ². ΠΠ·-Π·Π° Π½Π°Π»ΠΈΡΠΈΡ ΡΠ°ΡΡΠ΅ΡΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π½Π΅ΠΎΠ±Ρ
ΠΎΠ΄ΠΈΠΌΠΎ Π²Π½ΠΎΡΠΈΡΡ ΠΏΠΎΠΏΡΠ°Π²ΠΊΠΈ Π½Π° ΡΠ°ΡΡΠ΅ΡΠ½Π½ΡΡ ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½ΡΡ, ΠΎΠ±ΡΡΠ»ΠΎΠ²Π»Π΅Π½Π½ΡΡ ΡΠ°ΡΡΠ΅ΡΠ½ΠΈΠ΅ΠΌ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² Π² Π²ΠΎΠ·Π΄ΡΡ
Π΅ ΠΈ ΡΡΠ΅Π½Π°ΠΌΠΈ ΠΏΠΎΠΌΠ΅ΡΠ΅Π½ΠΈΡ. ΠΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΠ΅ Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠΈΡΡΠΈΠΊ Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΏΠΎΠ»Ρ ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ ΠΌΠΎΠ³ΡΡ Π±ΡΡΡ ΠΏΡΠΎΠ²Π΅Π΄Π΅Π½Ρ Π² ΠΎΠ³ΡΠ°Π½ΠΈΡΠ΅Π½Π½ΠΎΠΌ ΡΠΈΡΠ»Π΅ ΡΠΎΡΠ΅ΠΊ, Π° Π² ΠΎΡΡΠ°Π»ΡΠ½ΡΡ
ΡΠΎΡΠΊΠ°Ρ
ΠΈΡΠΏΠΎΠ»ΡΠ·ΡΠ΅ΡΡΡ ΠΌΠΎΠ΄Π΅Π»ΡΠ½ΡΠΉ ΠΌΠ΅ΡΠΎΠ΄.ΠΠΎΠ½ΡΠ΅ΠΉΠ½Π΅Ρ-ΠΊΠΎΠ»Π»ΠΈΠΌΠ°ΡΠΎΡ ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ ΡΠΎ Π²ΡΡΠ°Π²ΠΊΠΎΠΉ Π΄Π»Ρ Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΠΈ ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ
Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΡΠΎΡΠΌΠΈΡΡΠ΅Ρ ΠΏΡΡΠΎΠΊ ΠΎΡ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π½ΠΎΠ³ΠΎ ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ° Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΡΠΎ Π·Π½Π°ΡΠΈΡΠ΅Π»ΡΠ½ΠΎΠΉ ΡΠΎΡΡΠ°Π²Π»ΡΡΡΠ΅ΠΉ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ
ΡΠ½Π΅ΡΠ³ΠΈΠΉ. ΠΠ· ΠΏΠΎΠ»ΡΡΠ΅Π½Π½ΠΎΠΉ Π·Π°Π²ΠΈΡΠΈΠΌΠΎΡΡΠΈ ΠΏΠΎΠ»Π½ΠΎΠ³ΠΎ ΠΏΠΎΡΠΎΠΊΠ° Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΎΡ ΡΠ°ΡΡΡΠΎΡΠ½ΠΈΡ Π΄ΠΎ ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ° Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² Π²ΠΈΠ΄Π½ΠΎ, ΡΡΠΎ Π·Π° ΡΡΠ΅Ρ ΡΠ°ΡΡΠ΅ΡΠ½Π½ΠΎΠ³ΠΎ Π² ΠΊΠΎΠ»Π»ΠΈΠΌΠ°ΡΠΎΡΠ΅ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π½Π°ΡΡΡΠ°Π΅ΡΡΡ Π·Π°ΠΊΠΎΠ½ ΠΎΠ±ΡΠ°ΡΠ½ΡΡ
ΠΊΠ²Π°Π΄ΡΠ°ΡΠΎΠ². ΠΠΊΠ»Π°Π΄ ΡΠ°ΡΡΠ΅ΡΠ½Π½ΠΎΠ³ΠΎ ΡΡΠ΅Π½Π°ΠΌΠΈ ΠΏΠΎΠΌΠ΅ΡΠ΅Π½ΠΈΡ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π² ΠΏΠΎΠ»Π½ΡΠΉ ΠΏΠΎΡΠΎΠΊ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΡΠ²Π΅Π»ΠΈΡΠΈΠ²Π°Π΅ΡΡΡ ΠΏΡΠΈ ΡΠ΄Π°Π»Π΅Π½ΠΈΠΈ ΠΎΡ ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ° Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΈ Π·Π½Π°ΡΠΈΡΠ΅Π»ΡΠ½ΠΎ Π²Π»ΠΈΡΠ΅Ρ Π½Π° Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠΈΡΡΠΈΠΊΠΈ ΠΏΠΎΠ»Ρ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ². ΠΡΠΈ ΠΎΡΠΊΡΡΡΠΎΠΌ ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ΅ Π² Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΠΈ ΡΠ΅Π½Π΅Π²ΠΎΠ³ΠΎ ΠΊΠΎΠ½ΡΡΠ°, ΡΠΏΠ΅ΠΊΡΡ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΈΠΌΠ΅Π΅Ρ ΡΡΠΊΠΎ Π²ΡΡΠ°ΠΆΠ΅Π½Π½ΡΡ ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½ΡΡ, ΠΎΠ±ΡΡΠ»ΠΎΠ²Π»Π΅Π½Π½ΡΡ ΡΠ°ΡΡΠ΅ΡΠ½ΠΈΠ΅ΠΌ ΠΎΡ ΡΡΠ΅Π½.Π Π°ΡΡΠΌΠΎΡΡΠ΅Π½Ρ ΠΎΡΠ½ΠΎΠ²Π½ΡΠ΅ ΡΠΈΠΏΡ Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΠΉ Π΄Π»Ρ ΡΠΎΡΠΌΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΏΠΎΠ»Ρ ΡΡΠ°Π»ΠΎΠ½Π½ΠΎΠ³ΠΎ Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Ρ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π½ΡΡ
ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠΎΠ². Π Π°Π·ΡΠ°Π±ΠΎΡΠ°Π½Π° ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ ΠΌΠΎΠ΄Π΅Π»Ρ 238Pu-Be-ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ° Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΈ ΠΊΠΎΠ½ΡΠ΅ΠΉΠ½Π΅ΡΠ°-ΠΊΠΎΠ»Π»ΠΈΠΌΠ°ΡΠΎΡΠ° ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ Π£ΠΠ-ΠΠ’140. ΠΠΎΠΊΠ°Π·Π°Π½ΠΎ, ΡΡΠΎ Π½Π°ΠΈΠ±ΠΎΠ»Π΅Π΅ ΡΡΡΠ΅ΡΡΠ²Π΅Π½Π½ΡΠΌ ΡΠ°ΠΊΡΠΎΡΠΎΠΌ, Π²Π»ΠΈΡΡΡΠΈΠΌ Π½Π° ΡΠ½Π΅ΡΠ³Π΅ΡΠΈΡΠ΅ΡΠΊΠΎΠ΅ ΡΠ°ΡΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΠ΅ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ², ΡΠ²Π»ΡΠ΅ΡΡΡ Π²ΠΊΠ»Π°Π΄ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ, ΡΠ°ΡΡΠ΅ΡΠ½Π½ΠΎΠ³ΠΎ Π² ΠΏΠΎΠΌΠ΅ΡΠ΅Π½ΠΈΠΈ, Π³Π΄Π΅ ΡΠ°ΡΠΏΠΎΠ»ΠΎΠΆΠ΅Π½Π° ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠ°. ΠΡΠΎ ΠΏΡΠΈΠ²ΠΎΠ΄ΠΈΡ ΠΊ Π·Π½Π°ΡΠΈΡΠ΅Π»ΡΠ½ΠΎΠΌΡ ΠΈΠ·ΠΌΠ΅Π½Π΅Π½ΠΈΡ ΡΠΏΠ΅ΠΊΡΡΠ° Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΏΡΠΈ ΡΠ΄Π°Π»Π΅Π½ΠΈΠΈ ΠΎΡ ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ°. ΠΡΠΈ ΠΏΡΠΎΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΠΈ ΠΏΠΎΠΌΠ΅ΡΠ΅Π½ΠΈΡ ΠΈ ΡΠ°Π·ΠΌΠ΅ΡΠ΅Π½ΠΈΡ Π² Π½Π΅ΠΌ ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ Π½Π΅ΠΎΠ±Ρ
ΠΎΠ΄ΠΈΠΌΠΎ ΡΡΠΈΡΡΠ²Π°ΡΡ ΡΡΠ΅Π±ΠΎΠ²Π°Π½ΠΈΡ ΠΊ ΠΊΠ°ΡΠ΅ΡΡΠ²Ρ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ.
ΠΠΠΠΠ ΠΠΠΠ Π ΠΠΠΠΠΠΠ’ΠΠΠΠΠ‘Π’Π ΠΠΠ§Π ΠΠΠ’ΠΠΠΠ IN SITU
The results of Monte Carlo simulations of measurement of uniformly in-depth contaminated with Cs nuclides soil using scintillationΒ detector in situ measuring geometry have been discussed. The dependence of detector response functions on contaminationΒ depth is studied for nuclides 134Cs and 137Cs. Using the in situ methodology has shown the possibility of determining the depth of CsΒ nuclides distribution in soil without a preliminary sampling and analysis.ΠΠ±ΡΡΠΆΠ΄Π°ΡΡΡΡ ΡΠ΅Π·ΡΠ»ΡΡΠ°ΡΡ ΠΌΠΎΠ΄Π΅Π»ΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΌΠ΅ΡΠΎΠ΄ΠΎΠΌ ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ ΠΏΡΠΎΡΠ΅ΡΡΠ° in situ ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΠΉ Ρ ΠΏΠΎΠΌΠΎΡΡΡ ΡΡΠΈΠ½ΡΠΈΠ»Π»ΡΡΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ Π΄Π΅ΡΠ΅ΠΊΡΠΎΡΠ° Π·Π°Π³ΡΡΠ·Π½Π΅Π½Π½ΠΎΠΉ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π°ΠΌΠΈ ΡΠ΅Π·ΠΈΡ ΠΏΠΎΡΠ²Ρ. ΠΠ·ΡΡΠ΅Π½Π° Π·Π°Π²ΠΈΡΠΈΠΌΠΎΡΡΡ ΡΡΠ½ΠΊΡΠΈΠΉ ΠΎΡΠΊΠ»ΠΈΠΊΠ° Π΄Π΅ΡΠ΅ΠΊΡΠΎΡΠ° Π΄Π»ΡΒ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄ΠΎΠ² 134Cs ΠΈ 137Cs ΠΎΡ Π³Π»ΡΠ±ΠΈΠ½Ρ Π·Π°Π³ΡΡΠ·Π½Π΅Π½ΠΈΡ. ΠΠΎΠΊΠ°Π·Π°Π½Π° Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΡ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΡΠΎΠ»ΡΠΈΠ½Ρ Π·Π°Π³ΡΡΠ·Π½Π΅Π½Π½ΠΎΠ³ΠΎ ΡΠ»ΠΎΡΒ ΠΏΠΎΡΠ²Ρ ΠΏΡΠΈ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠΈ ΠΌΠ΅ΡΠΎΠ΄Π° in situ, Π±Π΅Π· ΠΏΡΠΎΠ²Π΅Π΄Π΅Π½ΠΈΡ ΠΏΡΠ΅Π΄Π²Π°ΡΠΈΡΠ΅Π»ΡΠ½ΠΎΠ³ΠΎ ΠΎΡΠ±ΠΎΡΠ° ΠΈ Π°Π½Π°Π»ΠΈΠ·Π° ΠΏΡΠΎΠ±
ΠΠ‘Π’ΠΠ§ΠΠΠ ΠΠΠ₯ΠΠΠ’ΠΠΠΠ ΠΠΠΠΠ-ΠΠΠΠ£Π§ΠΠΠΠ― Π‘ ΠΠΠΠ ΠΠΠ―ΠΠ ΠΠ 7 ΠΡΠ Π ΠΠ 10 ΠΡΠ ΠΠ ΠΠ‘ΠΠΠΠ ΠΠΠΠΠ ΠΠ§ΠΠΠ Π£Π‘Π’ΠΠΠΠΠΠ ΠΠΠΠ’Π ΠΠΠΠΠΠ ΠΠΠΠ£Π§ΠΠΠΠ―
Wide spread of technogenic sources of ionizing radiation such as particle accelerators and nuclear reactors leads to appearance of a number of applied metrological tasks aimed at providing spectrometric and dosimetric ionization measurement instruments, located in photon radiation fields with energy to 10 MeV. Gamma rays with energy higher 3 MeV may be acquired using radioactive thermal neutron capture on target, i.e. (n, Ξ³)-nuclear reaction. Titanium is used in the range of energies to 7 MeV; nickel β to 10 MeV. A simplest source of instantaneous neutron capture gamma-ray should consist of fast neutron source, neutron moderator and a target irradiated with thermal neutrons. The collimator with thermal neutron geometry of ΠΠ’140 neutron calibration facility with 238PuβBe fast neutron source may be used (IBNβ8β6) as a source of gamma-ray with energy to 10 MeV. Monte-Carlo models of thermal neutrons geometry, facility and 238PuβBe fast neutron source were built using MCNPβ4b code. Energy distribution of flux density of neutron capture gammaβray for titanium and nickel targets was defined. A spectrometric detector based on LaBr3(Ce) crystal Γ 38Γ38 mm with non-linear characteristics of channel-energy transformation in the range up to 10 MeV, was specifically manufactured for instrumental support of the experiment at SPE βATOMTEXβ. The results for Ti, Ni, and for bare 238PuβBe neutron source were acquired. During the experiment a possibility to use neutron capture gamma-ray field formed by thermal neutrons geometry of ΠΠ’140 neutron calibration facility with 238PuβBe-fast neutron source with Ti and Ni targets for calibration LaBr3(Ce) spectrometers for energy to 10 MeV was confirmed. Closely stationing polyethylene plate in collimator channel provides significant increase in output of reference radiation from target simultaneously decreasing unneeded parts of the spectrum.Β Π¨ΠΈΡΠΎΠΊΠΎΠ΅ ΡΠ°ΡΠΏΡΠΎΡΡΡΠ°Π½Π΅Π½ΠΈΠ΅ ΠΈ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ ΡΠ΅Ρ
Π½ΠΎΠ³Π΅Π½Π½ΡΡ
ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠΎΠ² ΠΈΠΎΠ½ΠΈΠ·ΠΈΡΡΡΡΠΈΡ
ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΠΉ, Π² ΡΠ°ΡΡΠ½ΠΎΡΡΠΈ ΡΠ°ΠΊΠΈΡ
, ΠΊΠ°ΠΊ ΡΡΠΊΠΎΡΠΈΡΠ΅Π»ΠΈ Π·Π°ΡΡΠΆΠ΅Π½Π½ΡΡ
ΡΠ°ΡΡΠΈΡ ΠΈ ΡΠ΄Π΅ΡΠ½ΡΠ΅ ΡΠ΅Π°ΠΊΡΠΎΡΡ, ΠΏΡΠΈΠ²ΠΎΠ΄ΠΈΡ ΠΊ ΠΏΠΎΡΠ²Π»Π΅Π½ΠΈΡ ΡΡΠ΄Π° ΠΏΡΠΈΠΊΠ»Π°Π΄Π½ΡΡ
Π·Π°Π΄Π°Ρ ΠΏΠΎ ΠΌΠ΅ΡΡΠΎΠ»ΠΎΠ³ΠΈΡΠ΅ΡΠΊΠΎΠΌΡ ΠΎΠ±Π΅ΡΠΏΠ΅ΡΠ΅Π½ΠΈΡ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΎΠΉ ΠΈ Π΄ΠΎΠ·ΠΈΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΎΠΉ Π°ΠΏΠΏΠ°ΡΠ°ΡΡΡΡ, ΡΠ°Π±ΠΎΡΠ°ΡΡΠ΅ΠΉ Π² ΠΏΠΎΠ»ΡΡ
ΡΠΎΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Ρ ΡΠ½Π΅ΡΠ³ΠΈΠ΅ΠΉ Π΄ΠΎ 10 ΠΡΠ. ΠΠΎΠ½ΡΠ΅ΠΉΠ½Π΅Ρ-ΠΊΠΎΠ»Π»ΠΈΠΌΠ°ΡΠΎΡ Ρ Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΠ΅ΠΉ ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ
Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ ΠΏΠΎΠ²Π΅ΡΠΎΡΠ½ΠΎΠΉ Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ (Π£ΠΠ- ΠΠ’140, Π£Π Β«ΠΠ’ΠΠΠ’ΠΠ₯Β») ΡΠΎΡΠΌΠΈΡΡΠ΅Ρ ΠΊΠΎΠ»Π»ΠΈΠΌΠΈΡΠΎΠ²Π°Π½Π½ΡΠΉ ΠΏΡΡΠΎΠΊ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΡΠΎ Π·Π½Π°ΡΠΈΡΠ΅Π»ΡΠ½ΠΎΠΉ ΡΠΎΡΡΠ°Π²Π»ΡΡΡΠ΅ΠΉ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ
ΡΠ½Π΅ΡΠ³ΠΈΠΉ. Π Π°ΡΠΏΠΎΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅ Π² ΠΏΠΎΡΠΎΠΊΠ΅ ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ
Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² Π΄ΠΈΡΠΊΠ° ΠΈΠ· ΡΠΈΡΠ°Π½Π° ΠΏΠΎΠ·Π²ΠΎΠ»ΡΠ΅Ρ ΠΏΠΎΠ»ΡΡΠΈΡΡ ΠΏΠΎΠ»Π΅ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π΄ΠΎ 7 ΠΡΠ, Π° Π΄ΠΈΡΠΊΠ° ΠΈΠ· Π½ΠΈΠΊΠ΅Π»Ρ β Π΄ΠΎ 10 ΠΡΠ. ΠΠ»Ρ ΡΠΊΡΠΏΠ΅ΡΠΈΠΌΠ΅Π½ΡΠ°Π»ΡΠ½ΠΎΠ³ΠΎ ΠΈΠ·ΡΡΠ΅Π½ΠΈΡ ΡΠΏΠ΅ΠΊΡΡΠ°Π»ΡΠ½ΡΡ
Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠΈΡΡΠΈΠΊ ΠΏΠΎΠ»Ρ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π»ΡΡ ΡΠΏΠ΅ΡΠΈΠ°Π»ΠΈΠ·ΠΈΡΠΎΠ²Π°Π½Π½ΡΠΉ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΠΉ Π±Π»ΠΎΠΊ Π΄Π΅ΡΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ Π½Π° ΠΎΡΠ½ΠΎΠ²Π΅ ΠΊΡΠΈΡΡΠ°Π»Π»Π° LaBr3(Ce) Ρ ΡΠ°Π·ΠΌΠ΅ΡΠ°ΠΌΠΈ Γ 38Γ38 ΠΌΠΌ Ρ Π½Π΅Π»ΠΈΠ½Π΅ΠΉΠ½ΠΎΠΉ Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠΈΡΡΠΈΠΊΠΎΠΉ ΠΏΡΠ΅ΠΎΠ±ΡΠ°Π·ΠΎΠ²Π°Π½ΠΈΡ ΠΊΠ°Π½Π°Π»-ΡΠ½Π΅ΡΠ³ΠΈΡ Π² Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ Π΄ΠΎ 10 ΠΡΠ. ΠΠ° ΡΠΏΠ΅ΠΊΡΡΠ°Ρ
Ρ
ΠΎΡΠΎΡΠΎ ΡΠ°Π·Π»ΠΈΡΠΈΠΌΡ ΠΎΡΠ½ΠΎΠ²Π½ΡΠ΅ Π»ΠΈΠ½ΠΈΠΈ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΎΡ Π²ΠΎΠ΄ΠΎΡΠΎΠ΄Π°, Π±ΠΎΡΠ°, ΡΠΈΡΠ°Π½Π° ΠΈ Π½ΠΈΠΊΠ΅Π»Ρ. ΠΠΎ ΠΏΠΎΠ»ΡΡΠ΅Π½Π½ΡΠΌ Π½Π° Π±Π»ΠΎΠΊΠ΅ Π΄Π΅ΡΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΡΠΏΠ΅ΠΊΡΡΠ°ΠΌ ΠΌΠΎΠΆΠ½ΠΎ ΡΠ΄Π΅Π»Π°ΡΡ Π²ΡΠ²ΠΎΠ΄ ΠΎ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΠΈ ΠΊΠ°Π»ΠΈΠ±ΡΠΎΠ²ΠΊΠΈ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΡ
Π±Π»ΠΎΠΊΠΎΠ² Π² ΠΏΠΎΠ»Π΅ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π΄ΠΎ 10 ΠΡΠ.
ΠΠΠΠΠ-Π‘ΠΠΠΠ’Π ΠΠΠΠ’Π ΠΠΠ― Π ΠΠΠΠΠ¦ΠΠΠΠΠΠΠ ΠΠΠΠΠ’ΠΠ ΠΠΠΠ ΠΠΠΠΠ’ΠΠ ΠΠ Π ΠΠΠΠΠ«Π₯ ΠΠ’ΠΠΠΠΠΠΠ
In order to solve the problem of continuous or periodic monitoring of water areas affected by radioactive contamination in the result of scheduled emissions in nuclear power plants or in the result of emergency situations in nuclear fuel cycle plants we need to develop measurement instruments with advanced mathematics and program support to assess the level of radioactive contamination with required accuracy. The aim of theoretical research was to optimize detection device construction, estimate spectrometer metrological parameters in given measurement geometries, and determine effective position of detection device in the process of in situ measurements. This device consists of spectrometric scintillation probe packed into sealed container (detection device) based on NaI(T1) crystal of Γ 63 Γ 63 mm or Γ 63 Γ 160 mm size, cable reel with deep-sea cable and a tablet PC for data processing and displaying. The container withstands static hydraulic pressure up to 5 MPa and can be used for measurements at depths of 500 m maximum. Probe measures energy distribution of gammaradiation with energy from 70 keV to 3000 keV. The implemented three-dimensional system for detection device position and orientation determination allows automatic operation of the device (without operator) for water areas or bottom sediment scanning. The spectrometer can output measurement results with threedimensional geographical coordinates as index maps of distribution with necessary resolution and accuracy. Monte Carlo models of spectrometer and controlled objects are developed in order to determine the detector response functions to given radionuclides in given measurement geometries without use of expensive standard measures of activity. Multifunction gamma-spectrometer for in situ radiation monitoring of water areas and bottom sediments was developed and constructed. In the result of theoretical researches the response functions have been calculated in the form of theoretical spectra of monitored radionuclides in definite measuring geometries. The results of mathematical modeling of the gamma-emitting transfer process allowed to estimate effective position of detection device for in situ measurements of specific activity radionuclides 134Cs and 137Cs in bottom sediments.Β ΠΠ°Π΄Π°ΡΠΈ ΠΏΠΎΡΡΠΎΡΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ»ΠΈ ΠΏΠ΅ΡΠΈΠΎΠ΄ΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΠΌΠΎΠ½ΠΈΡΠΎΡΠΈΠ½Π³Π° Π²ΠΎΠ΄ΠΎΠ΅ΠΌΠΎΠ², ΠΏΠΎΠ΄Π²Π΅ΡΠ³ΡΠΈΡ
ΡΡ ΡΠ°Π΄ΠΈΠΎΠ°ΠΊΡΠΈΠ²Π½ΠΎΠΌΡ Π·Π°Π³ΡΡΠ·Π½Π΅Π½ΠΈΡ Π² ΡΠ΅Π·ΡΠ»ΡΡΠ°ΡΠ΅ ΡΡΠ°ΡΠ½ΡΡ
Π²ΡΠ±ΡΠΎΡΠΎΠ² ΠΠΠ‘ ΠΈΠ»ΠΈ Π² ΡΠ΅Π·ΡΠ»ΡΡΠ°ΡΠ΅ Π²ΠΎΠ·Π½ΠΈΠΊΠ½ΠΎΠ²Π΅Π½ΠΈΡ Π½Π΅ΡΡΠ°ΡΠ½ΡΡ
ΡΠΈΡΡΠ°ΡΠΈΠΉ Π½Π° ΠΏΡΠ΅Π΄ΠΏΡΠΈΡΡΠΈΡΡ
ΡΠΎΠΏΠ»ΠΈΠ²Π½ΠΎΠ³ΠΎ ΡΠ΄Π΅ΡΠ½ΠΎΠ³ΠΎ ΡΠΈΠΊΠ»Π°, ΠΏΡΠΈΠ²ΠΎΠ΄ΡΡ ΠΊ Π½Π΅ΠΎΠ±Ρ
ΠΎΠ΄ΠΈΠΌΠΎΡΡΠΈ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠΊΠΈ ΡΠΎΠΎΡΠ²Π΅ΡΡΡΠ²ΡΡΡΠΈΡ
ΡΡΠ΅Π΄ΡΡΠ² ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΠΉ Ρ ΡΠΎΠ²ΡΠ΅ΠΌΠ΅Π½Π½ΡΠΌ ΠΌΠ°ΡΠ΅ΠΌΠ°ΡΠΈΡΠ΅ΡΠΊΠΈΠΌ ΠΈ ΠΏΡΠΎΠ³ΡΠ°ΠΌΠΌΠ½ΡΠΌ ΠΎΠ±Π΅ΡΠΏΠ΅ΡΠ΅Π½ΠΈΠ΅ΠΌ, ΠΏΠΎΠ·Π²ΠΎΠ»ΡΡΡΠΈΡ
ΠΎΡΠ΅Π½ΠΈΡΡ ΡΡΠΎΠ²Π΅Π½Ρ ΡΠ°Π΄ΠΈΠΎΠ°ΠΊΡΠΈΠ²Π½ΡΡ
Π·Π°Π³ΡΡΠ·Π½Π΅Π½ΠΈΠΉ Ρ Π·Π°Π΄Π°Π½Π½ΠΎΠΉ ΡΠΎΡΠ½ΠΎΡΡΡΡ. Π¦Π΅Π»Ρ ΡΠ΅ΠΎΡΠ΅ΡΠΈΡΠ΅ΡΠΊΠΈΡ
ΠΈΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΠΉ Π·Π°ΠΊΠ»ΡΡΠ°Π»Π°ΡΡ Π² ΠΎΠΏΡΠΈΠΌΠΈΠ·Π°ΡΠΈΠΈ ΠΊΠΎΠ½ΡΡΡΡΠΊΡΠΈΠ²Π° ΡΡΡΡΠΎΠΉΡΡΠ²Π° Π΄Π΅ΡΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ, ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΠΈ ΠΌΠ΅ΡΡΠΎΠ»ΠΎΠ³ΠΈΡΠ΅ΡΠΊΠΈΡ
ΠΏΠ°ΡΠ°ΠΌΠ΅ΡΡΠΎΠ² ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠ° Π² Π·Π°Π΄Π°Π½Π½ΡΡ
Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΡΡ
ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΡ, ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΠΈ ΡΡΡΠ΅ΠΊΡΠΈΠ²Π½ΠΎΠ³ΠΎ ΠΏΠΎΠ»ΠΎΠΆΠ΅Π½ΠΈΡ ΡΡΡΡΠΎΠΉΡΡΠ²Π° Π΄Π΅ΡΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠ° Π² ΠΏΡΠΎΡΠ΅ΡΡΠ΅ in situ ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΠΉ ΡΠ΄Π΅Π»ΡΠ½ΠΎΠΉ Π°ΠΊΡΠΈΠ²Π½ΠΎΡΡΠΈ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄ΠΎΠ² 134CsΒ ΠΈ 137CsΒ Π² Π΄ΠΎΠ½Π½ΡΡ
ΠΎΡΠ»ΠΎΠΆΠ΅Π½ΠΈΡΡ
Ρ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠ°Π½Π½ΡΡ
ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ ΠΌΠΎΠ΄Π΅Π»Π΅ΠΉ: ΡΡΡΡΠΎΠΉΡΡΠ²Π° Π΄Π΅ΡΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ, Π²ΠΎΠ΄Ρ ΠΈ Π΄ΠΎΠ½Π½ΡΡ
ΠΎΡΠ»ΠΎΠΆΠ΅Π½ΠΈΠΉ. Π‘ΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡ ΠΏΡΠ΅Π΄ΡΡΠ°Π²Π»ΡΠ΅Ρ ΡΠΎΠ±ΠΎΠΉ ΠΌΠ½ΠΎΠ³ΠΎΡΡΠ½ΠΊΡΠΈΠΎΠ½Π°Π»ΡΠ½ΡΠΉ ΠΏΡΠΈΠ±ΠΎΡ, ΡΠΎΡΡΠΎΡΡΠΈΠΉ ΠΈΠ· ΡΠ°Π·ΠΌΠ΅ΡΠ°Π΅ΠΌΠΎΠ³ΠΎ Π² Π³Π΅ΡΠΌΠ΅ΡΠΈΡΠ½ΠΎΠΌ ΠΊΠΎΠ½ΡΠ΅ΠΉΠ½Π΅ΡΠ΅ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΡΡΠΈΠ½ΡΠΈΠ»Π»ΡΡΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° Π΄Π΅ΡΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ Ρ ΠΊΡΠΈΡΡΠ°Π»Π»ΠΎΠΌ NaI(T1) ΡΠ°Π·ΠΌΠ΅ΡΠ°ΠΌΠΈ Γ 63 Γ 63 ΠΌΠΌ ΠΈΠ»ΠΈ Γ 63 Γ 160 ΠΌΠΌ, Π²ΡΡΡΠΊΠΈ Ρ Π³Π»ΡΠ±ΠΎΠΊΠΎΠ²ΠΎΠ΄Π½ΡΠΌ ΠΊΠ°Π±Π΅Π»Π΅ΠΌ ΠΈ ΠΏΠ»Π°Π½ΡΠ΅ΡΠ½ΠΎΠ³ΠΎ ΠΊΠΎΠΌΠΏΡΡΡΠ΅ΡΠ° Π΄Π»Ρ ΠΎΠ±ΡΠ°Π±ΠΎΡΠΊΠΈ ΠΈ ΠΎΡΠΎΠ±ΡΠ°ΠΆΠ΅Π½ΠΈΡ ΠΈΠ½ΡΠΎΡΠΌΠ°ΡΠΈΠΈ. ΠΠΎΠ½ΡΠ΅ΠΉΠ½Π΅Ρ ΡΡΡΠΎΠΉΡΠΈΠ² ΠΊ ΡΡΠ°ΡΠΈΡΠ΅ΡΠΊΠΎΠΌΡ Π³ΠΈΠ΄ΡΠ°Π²Π»ΠΈΡΠ΅ΡΠΊΠΎΠΌΡ Π΄Π°Π²Π»Π΅Π½ΠΈΡ Π΄ΠΎ 5 ΠΠΠ°, ΡΡΠΎ ΠΏΠΎΠ·Π²ΠΎΠ»ΡΠ΅Ρ ΠΏΡΠΎΠ²ΠΎΠ΄ΠΈΡΡ ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΡ Π½Π° Π³Π»ΡΠ±ΠΈΠ½Π°Ρ
Π΄ΠΎ 500 ΠΌ. Π£ΡΡΡΠΎΠΉΡΡΠ²ΠΎ Π΄Π΅ΡΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΏΠΎΠ·Π²ΠΎΠ»ΡΠ΅Ρ ΠΈΠ·ΠΌΠ΅ΡΡΡΡ ΡΠ½Π΅ΡΠ³Π΅ΡΠΈΡΠ΅ΡΠΊΠΎΠ΅ ΡΠ°ΡΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΠ΅ ΠΈΠΌΠΏΡΠ»ΡΡΠΎΠ² Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Ρ ΡΠ½Π΅ΡΠ³ΠΈΠ΅ΠΉ ΠΎΡ 70 Π΄ΠΎ 3000 ΠΊΡΠ. Π Π΅Π°Π»ΠΈΠ·ΠΎΠ²Π°Π½Π½Π°Ρ ΡΠΈΡΡΠ΅ΠΌΠ° ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΠΏΠΎΠ»ΠΎΠΆΠ΅Π½ΠΈΡ ΡΡΡΡΠΎΠΉΡΡΠ²Π° Π΄Π΅ΡΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ Π² ΠΏΡΠΎΡΡΡΠ°Π½ΡΡΠ²Π΅ ΠΏΠΎΠ·Π²ΠΎΠ»ΡΠ΅Ρ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°ΡΡ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡ Π² Π°Π²ΡΠΎΠΌΠ°ΡΠΈΡΠ΅ΡΠΊΠΎΠΌ ΡΠ΅ΠΆΠΈΠΌΠ΅ (Π±Π΅Π· ΡΡΠ°ΡΡΠΈΡ ΠΎΠΏΠ΅ΡΠ°ΡΠΎΡΠ°) Π΄Π»Ρ ΡΠΊΠ°Π½ΠΈΡΠΎΠ²Π°Π½ΠΈΡ Π²ΠΎΠ΄Π½ΠΎΠΉ Π°ΠΊΠ²Π°ΡΠΎΡΠΈΠΈ ΠΈ Π΄ΠΎΠ½Π½ΡΡ
ΠΎΡΠ»ΠΎΠΆΠ΅Π½ΠΈΠΉ. Π Π΅Π·ΡΠ»ΡΡΠ°ΡΡ ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΡ Π·Π°Π΄Π°Π½Π½ΠΎΠΉ Π²Π΅Π»ΠΈΡΠΈΠ½Ρ Ρ ΡΡΠ΅Ρ
ΠΌΠ΅ΡΠ½ΡΠΌΠΈ Π³Π΅ΠΎΠ³ΡΠ°ΡΠΈΡΠ΅ΡΠΊΠΈΠΌΠΈ ΠΊΠΎΠΎΡΠ΄ΠΈΠ½Π°ΡΠ°ΠΌΠΈ ΠΌΠΎΠ³ΡΡ Π±ΡΡΡ ΠΎΠΏΠ΅ΡΠ°ΡΠΈΠ²Π½ΠΎ ΠΏΡΠ΅Π΄ΡΡΠ°Π²Π»Π΅Π½Ρ Π² Π²ΠΈΠ΄Π΅ ΠΊΠ°ΡΡ-ΡΡ
Π΅ΠΌ ΡΠ°ΡΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Ρ Π½Π΅ΠΎΠ±Ρ
ΠΎΠ΄ΠΈΠΌΠΎΠΉ Π΄ΠΈΡΠΊΡΠ΅ΡΠ½ΠΎΡΡΡΡ ΠΈ ΡΠΎΡΠ½ΠΎΡΡΡΡ. ΠΠ»Ρ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΡΡΠ½ΠΊΡΠΈΠΉ ΠΎΡΠΊΠ»ΠΈΠΊΠ° Π΄Π΅ΡΠ΅ΠΊΡΠΎΡΠ° ΠΊ Π·Π°Π΄Π°Π½Π½ΡΠΌ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π°ΠΌ Π² ΡΡΠ΅Π±ΡΠ΅ΠΌΡΡ
Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΡΡ
ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΡ Π±Π΅Π· ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΡ ΡΠΈΠ·ΠΈΡΠ΅ΡΠΊΠΈΡ
Π΄ΠΎΡΠΎΠ³ΠΎΡΡΠΎΡΡΠΈΡ
ΡΡΠ°Π½Π΄Π°ΡΡΠ½ΡΡ
ΠΌΠ΅Ρ Π°ΠΊΡΠΈΠ²Π½ΠΎΡΡΠΈ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠ°Π½Ρ ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ ΠΌΠΎΠ΄Π΅Π»ΠΈ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠ° ΠΈ ΠΎΠ±ΡΠ΅ΠΊΡΠΎΠ² ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ. ΠΠ»Ρ ΡΠ°Π΄ΠΈΠ°ΡΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ Π²ΠΎΠ΄Π½ΠΎΠΉ ΡΡΠ΅Π΄Ρ ΠΈ Π΄ΠΎΠ½Π½ΡΡ
ΠΎΡΠ»ΠΎΠΆΠ΅Π½ΠΈΠΉ ΠΌΠ΅ΡΠΎΠ΄ΠΎΠΌ in situ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠ°Π½ ΠΈ ΠΈΠ·Π³ΠΎΡΠΎΠ²Π»Π΅Π½ ΠΌΠ½ΠΎΠ³ΠΎΡΡΠ½ΠΊΡΠΈΠΎΠ½Π°Π»ΡΠ½ΡΠΉ ΠΏΠΎΡΡΠ°ΡΠΈΠ²Π½ΡΠΉ Π³Π°ΠΌΠΌΠ°-ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡ. Π ΡΠ΅Π·ΡΠ»ΡΡΠ°ΡΠ΅ ΡΠ΅ΠΎΡΠ΅ΡΠΈΡΠ΅ΡΠΊΠΈΡ
ΠΈΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΠΉ Π±ΡΠ»ΠΈ ΡΠ°ΡΡΡΠΈΡΠ°Π½Ρ ΡΡΠ½ΠΊΡΠΈΠΈ ΠΎΡΠΊΠ»ΠΈΠΊΠ° ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠ° ΠΊ ΠΊΠΎΠ½ΡΡΠΎΠ»ΠΈΡΡΠ΅ΠΌΡΠΌ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π°ΠΌ Π² Π·Π°Π΄Π°Π½Π½ΡΡ
Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΡΡ
ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΡ. Π Π΅Π·ΡΠ»ΡΡΠ°ΡΡ ΠΌΠ°ΡΠ΅ΠΌΠ°ΡΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΠΌΠΎΠ΄Π΅Π»ΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΏΡΠΎΡΠ΅ΡΡΠ° ΠΏΠ΅ΡΠ΅Π½ΠΎΡΠ° Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΏΠΎΠ·Π²ΠΎΠ»ΠΈΠ»ΠΈ ΠΎΠΏΡΠ΅Π΄Π΅Π»ΠΈΡΡ ΡΡΡΠ΅ΠΊΡΠΈΠ²Π½ΡΡ ΠΏΠΎΠ·ΠΈΡΠΈΡ ΡΡΡΡΠΎΠΉΡΡΠ²Π° Π΄Π΅ΡΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ Π² ΠΏΡΠΎΡΠ΅ΡΡΠ΅ in situ ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΠΉ Π°ΠΊΡΠΈΠ²Π½ΠΎΡΡΠΈ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄ΠΎΠ² 134Cs ΠΈ 137Cs Π² Π΄ΠΎΠ½Π½ΡΡ
ΠΎΡΠ»ΠΎΠΆΠ΅Π½ΠΈΡΡ
.
Π€ΠΠ ΠΠΠ ΠΠΠΠΠΠ ΠΠΠΠ― ΠΠΠ₯ΠΠΠ’ΠΠΠΠ ΠΠΠΠΠ-ΠΠΠΠ£Π§ΠΠΠΠ― ΠΠ 10 ΠΡΠ ΠΠΠ― ΠΠΠ’Π ΠΠΠΠΠΠ§ΠΠ‘ΠΠΠΠ ΠΠΠΠ‘ΠΠΠ§ΠΠΠΠ― ΠΠ ΠΠΠΠ ΠΠ Π ΠΠΠΠΠ¦ΠΠΠΠΠΠ ΠΠΠ©ΠΠ’Π«
Medical, and technological linear particle accelerators, and nuclear reactors are vastly widespread worldwide today. These facility generate fields of secondary gamma radiation with energy to 10 MeV. Therefore, we have a need to calibrate spectrometric and dosimetric ionization measurement instruments for the energies to 10 MeV. The aim of this work is to determine possibility to use thermal neutron collimator of ΠΠ’140 Neutron Calibration Facility with 238Pu-Be fast neutron source (IBN-8-6) for this. Below 3 MeV we use a set of point gamma standard spectrometry sources OSGI. We can acquire gamma rays with energies above 3 MeV using radioactive thermal neutron capture on target, i.e. (n, Ξ³)-nuclear reaction. We can use neutron capture gamma-ray from titanium target (to 7 MeV) or nickel target (to 10 MeV) situated in thermal neutron field for calibration. We can use thermal neutron collimator of ΠΠ’140 Neutron Calibration Facility with 238Pu-Be fast neutron source (IBN-8-6) for slowing down neutrons from radionuclide fast neutron sources to thermal energies in polyethylene. Thermal neutron collimator forms a beam from radionuclide source with a significant amount of neutrons with thermal energies. We placed Ti and Ni targets in collimatorβs canal. We got experimental spectral data on detection unit BDKG-19M NaI(Tl) 63βΓβ160 mm with nonlinear channel-energy conversion characteristic in range to 10 MeV. For additional filtration we proposed to use polyethylene neutron reflector and lead discs. We experimentally determined that placement of lead discs in collimator in front of the target allows to filter all spectrum while insignificantly weakening targetβs emission. Using theoretical and experimental data we proved the ability to calibrate gamma-ray spectrometers in the range to 10 MeV.Β Π Π°Π·Π²ΠΈΡΠΈΠ΅ ΠΈ ΡΠ°ΡΠΏΡΠΎΡΡΡΠ°Π½Π΅Π½ΠΈΠ΅ ΡΠ΅Ρ
Π½ΠΎΠ³Π΅Π½Π½ΡΡ
ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠΎΠ² Π²ΡΡΠΎΠΊΠΎΡΠ½Π΅ΡΠ³Π΅ΡΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ Π²ΡΠΎΡΠΈΡΠ½ΠΎΠ³ΠΎ Π³Π°ΠΌΠΌΠ°ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΏΡΠΈΠ²ΠΎΠ΄ΠΈΡ ΠΊ ΡΡΠ΄Ρ ΠΏΡΠΈΠΊΠ»Π°Π΄Π½ΡΡ
Π·Π°Π΄Π°Ρ ΡΠ°Π΄ΠΈΠ°ΡΠΈΠΎΠ½Π½ΠΎΠΉ Π·Π°ΡΠΈΡΡ, Π² ΠΊΠΎΡΠΎΡΡΡ
ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΠ΅ ΠΈ Π΄ΠΎΠ·ΠΈΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΠ΅ ΠΈΠ·ΠΌΠ΅ΡΠΈΡΠ΅Π»ΡΠ½ΡΠ΅ ΠΏΡΠΈΠ±ΠΎΡΡ ΠΈΡΠΏΠΎΠ»ΡΠ·ΡΡΡΡΡ Π² ΡΠΎΡΠΎΠ½Π½ΡΡ
ΠΏΠΎΠ»ΡΡ
Π² Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ ΡΠ½Π΅ΡΠ³ΠΈΠΉ ΠΎΡ 4 Π΄ΠΎ 10 ΠΡΠ. Π¦Π΅Π»ΡΡ Π΄Π°Π½Π½ΠΎΠΉ ΡΠ°Π±ΠΎΡΡ ΡΠ²Π»ΡΠ»Π°ΡΡ ΠΏΡΠΎΠ²Π΅ΡΠΊΠ° Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΠΈ ΡΠΎΡΠΌΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΡΡΠ°Π»ΠΎΠ½Π½ΡΡ
ΠΏΠΎΠ»Π΅ΠΉ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΏΡΠΈ ΠΏΠΎΠΌΠΎΡΠΈ ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ° Π±ΡΡΡΡΡΡ
Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΈ ΠΌΠΈΡΠ΅Π½Π΅ΠΉ ΠΈΠ· ΡΠΈΡΠ°Π½Π° ΠΈ Π½ΠΈΠΊΠ΅Π»Ρ Ρ ΡΠ½Π΅ΡΠ³ΠΈΡΠΌΠΈ Π΄ΠΎ 10 ΠΡΠ. ΠΠΎΡΡΠ΅ΠΊΡΠ½Π°Ρ ΠΊΠ°Π»ΠΈΠ±ΡΠΎΠ²ΠΊΠ° ΠΏΡΠ΅Π΄ΠΏΠΎΠ»Π°Π³Π°Π΅Ρ Π½Π°Π»ΠΈΡΠΈΠ΅ Π² ΡΡΠ°Π»ΠΎΠ½Π½ΠΎΠΌ ΡΠΏΠ΅ΠΊΡΡΠ΅ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΎΠ΄ΠΈΠ½ΠΎΡΠ½ΡΡ
Π»ΠΈΠ½ΠΈΠΉ Ρ ΠΈΠ·Π²Π΅ΡΡΠ½ΠΎΠΉ ΡΠ½Π΅ΡΠ³ΠΈΠ΅ΠΉ. ΠΠΎ 3 ΠΡΠ Π·Π°Π΄Π°ΡΠ° ΡΠ΅ΡΠ°Π΅ΡΡΡ ΠΏΡΠΈ ΠΏΠΎΠΌΠΎΡΠΈ Π½Π°Π±ΠΎΡΠ° ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π½ΡΡ
ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠΎΠ² ΠΠ‘ΠΠ. ΠΠ»Ρ ΡΠΎΡΠΌΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΡΡΠ°Π»ΠΎΠ½Π½ΠΎΠ³ΠΎ ΡΠΎΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΏΠΎΠ»Ρ Ρ ΡΠ½Π΅ΡΠ³ΠΈΡΠΌΠΈ Π΄ΠΎ 10 ΠΡΠ ΠΌΠΎΠΆΠ½ΠΎ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°ΡΡ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ΅ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΠ΅ ΠΎΡ ΠΌΠΈΡΠ΅Π½Π΅ΠΉ ΠΈΠ· ΡΠΈΡΠ°Π½Π° ΠΈ Π½ΠΈΠΊΠ΅Π»Ρ, Π½Π°Ρ
ΠΎΠ΄ΡΡΠΈΡ
ΡΡ Π² ΠΏΠΎΠ»Π΅ ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ
Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ². ΠΠΎΡΠΎΠΊ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² Ρ ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΠΌΠΈ ΡΠ½Π΅ΡΠ³ΠΈΡΠΌΠΈ ΠΌΠΎΠΆΠ΅Ρ Π±ΡΡΡ ΠΏΠΎΠ»ΡΡΠ΅Π½ Π·Π°ΠΌΠ΅Π΄Π»Π΅Π½ΠΈΠ΅ΠΌ Π±ΡΡΡΡΡΡ
Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΎΡ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π½ΡΡ
ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠΎΠ² 238Pu-Be, 252Cf, 241Am-Be. Π ΠΊΠ°ΡΠ΅ΡΡΠ²Π΅ Π·Π°ΠΌΠ΅Π΄Π»ΠΈΡΠ΅Π»Ρ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΎΠ±ΡΡΠ½ΠΎ ΠΈΡΠΏΠΎΠ»ΡΠ·ΡΡΡΡΡ Π²ΠΎΠ΄ΠΎΡΠΎΠ΄ΠΎΡΠΎΠ΄Π΅ΡΠΆΠ°ΡΠΈΠ΅ ΠΌΠ°ΡΠ΅ΡΠΈΠ°Π»Ρ (ΠΏΠΎΠ»ΠΈΡΡΠΈΠ»Π΅Π½ ΠΈ ΠΏΠ°ΡΠ°ΡΠΈΠ½). ΠΠΎΠ»Π»ΠΈΠΌΠ°ΡΠΎΡ ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ
Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ ΠΏΠΎΠ²Π΅ΡΠΎΡΠ½ΠΎΠΉ Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ (Π£ΠΠ-ΠΠ’140, Π£Π Β«ΠΠ’ΠΠΠ’ΠΠ₯Β») ΡΠΎΡΠΌΠΈΡΡΠ΅Ρ ΠΏΡΡΠΎΠΊ ΠΎΡ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π½ΠΎΠ³ΠΎ ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ° ΡΠΎ Π·Π½Π°ΡΠΈΡΠ΅Π»ΡΠ½ΠΎΠΉ ΡΠΎΡΡΠ°Π²Π»ΡΡΡΠ΅ΠΉ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ
ΡΠ½Π΅ΡΠ³ΠΈΠΉ. Π Π°Π·ΠΌΠ΅ΡΠ΅Π½ΠΈΠ΅ ΠΌΠΈΡΠ΅Π½Π΅ΠΉ Π² ΠΊΠ°Π½Π°Π»Π΅ ΠΊΠΎΠ»Π»ΠΈΠΌΠ°ΡΠΎΡΠ° ΠΏΠΎΠ·Π²ΠΎΠ»ΠΈΠ»ΠΎ ΠΏΠΎΠ»ΡΡΠΈΡΡ ΠΏΠΎΠ»Π΅ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Ρ Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠ½ΡΠΌΠΈ Π΄Π»Ρ ΠΌΠ°ΡΠ΅ΡΠΈΠ°Π»Π° ΠΌΠΈΡΠ΅Π½ΠΈ ΡΠ½Π΅ΡΠ³ΠΈΡΠΌΠΈ. ΠΠΊΡΠΏΠ΅ΡΠΈΠΌΠ΅Π½ΡΠ°Π»ΡΠ½ΡΠ΅ ΡΠΏΠ΅ΠΊΡΡΡ ΠΏΠΎΠ»ΡΡΠ΅Π½Ρ Π½Π° ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΎΠΌ Π±Π»ΠΎΠΊΠ΅ Π΄Π΅ΡΠ΅ΠΊΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΠΠΠ-19Π NaI(Tl) 63βΓβ160 ΠΌΠΌ Ρ Π½Π΅Π»ΠΈΠ½Π΅ΠΉΠ½ΠΎΠΉ Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠΈΡΡΠΈΠΊΠΎΠΉ ΠΏΡΠ΅ΠΎΠ±ΡΠ°Π·ΠΎΠ²Π°Π½ΠΈΡ ΠΊΠ°Π½Π°Π»-ΡΠ½Π΅ΡΠ³ΠΈΡ Π² Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ Π΄ΠΎ 10 ΠΡΠ. ΠΠ° ΡΠΏΠ΅ΠΊΡΡΠ°Ρ
Ρ
ΠΎΡΠΎΡΠΎ ΡΠ°Π·Π»ΠΈΡΠΈΠΌΡ ΠΎΡΠ½ΠΎΠ²Π½ΡΠ΅ Π»ΠΈΠ½ΠΈΠΈ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΎΡ Π²ΠΎΠ΄ΠΎΡΠΎΠ΄Π°, ΡΠΈΡΠ°Π½Π° ΠΈ Π½ΠΈΠΊΠ΅Π»Ρ. Π ΠΊΠ°ΡΠ΅ΡΡΠ²Π΅ Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡΠ΅Π»ΡΠ½ΠΎΠΉ ΡΠΈΠ»ΡΡΡΠ°ΡΠΈΠΈ ΠΏΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½ΠΎ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°ΡΡ ΠΎΡΡΠ°ΠΆΠ°ΡΠ΅Π»Ρ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΈΠ· ΠΏΠΎΠ»ΠΈΡΡΠΈΠ»Π΅Π½Π° ΠΈ ΡΠ²ΠΈΠ½ΡΠΎΠ²ΡΠ΅ Π΄ΠΈΡΠΊΠΈ. ΠΠΎΠΊΠ°Π·Π°Π½ΠΎ, ΡΡΠΎ ΡΠ°Π·ΠΌΠ΅ΡΠ΅Π½ΠΈΠ΅ Π΄ΠΈΡΠΊΠΎΠ² ΠΈΠ· ΡΠ²ΠΈΠ½ΡΠ° Π² ΠΊΠΎΠ»Π»ΠΈΠΌΠ°ΡΠΎΡΠ΅ ΠΏΠ΅ΡΠ΅Π΄ ΠΌΠΈΡΠ΅Π½ΡΡ ΠΏΠΎΠ·Π²ΠΎΠ»ΡΠ΅Ρ ΡΠΈΠ»ΡΡΡΠΎΠ²Π°ΡΡ Π²Π΅ΡΡ ΡΠΏΠ΅ΠΊΡΡ, ΠΏΡΠΈ ΡΡΠΎΠΌ Π½Π΅Π·Π½Π°ΡΠΈΡΠ΅Π»ΡΠ½ΠΎ ΠΎΡΠ»Π°Π±Π»ΡΡ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΠ΅ ΠΈΠΌΠ΅Π½Π½ΠΎ ΠΎΡ ΠΌΠΈΡΠ΅Π½ΠΈ. ΠΠ° ΠΎΡΠ½ΠΎΠ²Π°Π½ΠΈΠΈ ΡΠ΅ΠΎΡΠ΅ΡΠΈΡΠ΅ΡΠΊΠΈΡ
ΠΈ ΡΠΊΡΠΏΠ΅ΡΠΈΠΌΠ΅Π½ΡΠ°Π»ΡΠ½ΡΡ
Π΄Π°Π½Π½ΡΡ
ΠΏΠΎΠ΄ΡΠ²Π΅ΡΠΆΠ΄Π΅Π½Π° Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΡ ΠΊΠ°Π»ΠΈΠ±ΡΠΎΠ²ΠΊΠΈ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΎΠ² Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π² Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ Π΄ΠΎ 10 ΠΡΠ Π² ΠΏΠΎΠ»Π΅ ΠΌΠ³Π½ΠΎΠ²Π΅Π½Π½ΠΎΠ³ΠΎ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ.
ΠΠΠ’Π ΠΠΠΠΠΠ§ΠΠ‘ΠΠΠ ΠΠΠΠ‘ΠΠΠ§ΠΠΠΠ ΠΠΠΠΠΠΠ’Π ΠΠ ΠΠΠΠΠ-ΠΠΠΠ£Π§ΠΠΠΠ― Π‘ ΠΠΠΠ ΠΠΠΠ ΠΠ 10 ΠΠΠ ΠΠΠ― ΠΠ ΠΠΠΠ ΠΠ Π ΠΠΠΠΠ¦ΠΠΠΠΠΠ ΠΠΠ©ΠΠ’Π«
The field of high-energy gamma-ray for the calibration of radiation protection devices can be obtained by capturing thermal neutrons from titanium target (to 7 MeV) and nickel target (to 10 MeV). The aim of this work was to determine the metrological characteristics of capture gamma-ray fields from titanium target and nickel target obtained at the AT140 Neutron Calibration Facility to provide dosimetry up to 10 MeV.We have chosen energy intervals in which we can calibrate dosimetry devices taking into account the accompanying generation of gamma-ray neutrons by the fast neutron source 238PuBe, the capture radiation of collimator materials and capture radiation from targets.We measured air kerma rate with the aid of the reference AT5350 dosimeter with the ionization chamber TM32002. Using the Monte-Carlo simulation, we obtained the energy distribution of the air kerma rate for targets. We determined the geometric dimensions of the uniform field and the interval of operating distances of the facility.We investigated the metrological characteristics of capture gamma-ray fields from titanium target and nickel target obtained at the AT140 Neutron Calibration Facility for dosimetric radiation protection devices. We showed that in such fields it is possible to calibrate dosimetry devices in the extended energy range up to 10 MeV.Β ΠΠΎΠ»Π΅ Π²ΡΡΠΎΠΊΠΎΡΠ½Π΅ΡΠ³Π΅ΡΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π΄Π»Ρ ΠΊΠ°Π»ΠΈΠ±ΡΠΎΠ²ΠΊΠΈ ΠΏΡΠΈΠ±ΠΎΡΠΎΠ² ΡΠ°Π΄ΠΈΠ°ΡΠΈΠΎΠ½Π½ΠΎΠΉ Π·Π°ΡΠΈΡΡ ΠΌΠΎΠΆΠ½ΠΎ ΠΏΠΎΠ»ΡΡΠΈΡΡ Π² ΡΠ΅Π·ΡΠ»ΡΡΠ°ΡΠ΅ Π·Π°Ρ
Π²Π°ΡΠ° ΡΠ΅ΠΏΠ»ΠΎΠ²ΡΡ
Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² Π½Π° ΠΌΠΈΡΠ΅Π½ΡΡ
ΠΈΠ· ΡΠΈΡΠ°Π½Π° (Π΄ΠΎ 7 ΠΡΠ) ΠΈ Π½ΠΈΠΊΠ΅Π»Ρ (Π΄ΠΎ 10 ΠΡΠ). Π¦Π΅Π»ΡΡ Π΄Π°Π½Π½ΠΎΠΉ ΡΠ°Π±ΠΎΡΡ ΡΠ²Π»ΡΠ»ΠΎΡΡ ΠΈΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΠ΅ ΠΏΠΎΠ»Π΅ΠΉ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ Π³Π°ΠΌΠΌΠ°ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΎΡ ΠΌΠΈΡΠ΅Π½Π΅ΠΉ ΠΈΠ· ΡΠΈΡΠ°Π½Π° ΠΈ Π½ΠΈΠΊΠ΅Π»Ρ, ΠΏΠΎΠ»ΡΡΠ΅Π½Π½ΡΡ
Ρ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ ΠΎΠ±Π»ΡΡΠ°ΡΠ΅Π»Ρ ΠΏΠΎΠ²Π΅ΡΠΎΡΠ½ΠΎΠΉ ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π£ΠΠ-ΠΠ’140 Π΄Π»Ρ ΠΎΠ±Π΅ΡΠΏΠ΅ΡΠ΅Π½ΠΈΡ Π΄ΠΎΠ·ΠΈΠΌΠ΅ΡΡΠΈΠΈ Π΄ΠΎ 10 ΠΡΠ.Π Ρ
ΠΎΠ΄Π΅ ΡΠ°Π±ΠΎΡΡ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½Ρ ΡΠ½Π΅ΡΠ³Π΅ΡΠΈΡΠ΅ΡΠΊΠΈΠ΅ ΠΈΠ½ΡΠ΅ΡΠ²Π°Π»Ρ, Π² ΠΊΠΎΡΠΎΡΡΡ
ΠΌΠΎΠΆΠ½ΠΎ ΠΊΠ°Π»ΠΈΠ±ΡΠΎΠ²Π°ΡΡ Π΄ΠΎΠ·ΠΈΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΠ΅ ΠΏΡΠΈΠ±ΠΎΡΡ Ρ ΡΡΠ΅ΡΠΎΠΌ ΡΠΎΠΏΡΡΡΡΠ²ΡΡΡΠ΅Π³ΠΎ Π²ΡΡ
ΠΎΠ΄Ρ Π½Π΅ΠΉΡΡΠΎΠ½ΠΎΠ² ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠ° 238PuBe Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΌΠ°ΡΠ΅ΡΠΈΠ°Π»ΠΎΠ² ΠΊΠΎΠ»Π»ΠΈΠΌΠ°ΡΠΎΡΠ° ΠΈ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΎΡ ΠΌΠΈΡΠ΅Π½Π΅ΠΉ.ΠΠ»Ρ ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΡ ΠΌΠΎΡΠ½ΠΎΡΡΠΈ ΠΊΠ΅ΡΠΌΡ Π² Π²ΠΎΠ·Π΄ΡΡ
Π΅ Π³Π°ΠΌΠΌΠ°-ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π»ΡΡ ΡΡΠ°Π»ΠΎΠ½Π½ΡΠΉ Π΄ΠΎΠ·ΠΈΠΌΠ΅ΡΡ ΠΠΠ‘-ΠΠ’5350 Ρ ΠΈΠΎΠ½ΠΈΠ·Π°ΡΠΈΠΎΠ½Π½ΠΎΠΉ ΠΊΠ°ΠΌΠ΅ΡΠΎΠΉ Π’Π32002. Π‘ ΠΏΠΎΠΌΠΎΡΡΡ ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ ΠΌΠΎΠ΄Π΅Π»ΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΏΠΎΠ»ΡΡΠ΅Π½ΠΎ ΡΠ½Π΅ΡΠ³Π΅ΡΠΈΡΠ΅ΡΠΊΠΎΠ΅ ΡΠ°ΡΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΠ΅ ΠΌΠΎΡΠ½ΠΎΡΡΠΈ ΠΊΠ΅ΡΠΌΡ Π² Π²ΠΎΠ·Π΄ΡΡ
Π΅ Π΄Π»Ρ ΠΌΠΈΡΠ΅Π½Π΅ΠΉ. Π£ΡΡΠ°Π½ΠΎΠ²Π»Π΅Π½Ρ Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΠ΅ ΡΠ°Π·ΠΌΠ΅ΡΡ ΡΠ°Π²Π½ΠΎΠΌΠ΅ΡΠ½ΠΎΠ³ΠΎ ΠΏΠΎΠ»Ρ ΠΈ ΠΈΠ½ΡΠ΅ΡΠ²Π°Π» ΡΠ°Π±ΠΎΡΠΈΡ
ΡΠ°ΡΡΡΠΎΡΠ½ΠΈΠΉ ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠΈ.ΠΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½Ρ Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠΈΡΡΠΈΠΊΠΈ ΠΏΠΎΠ»Π΅ΠΉ Π·Π°Ρ
Π²Π°ΡΠ½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΎΡ ΠΌΠΈΡΠ΅Π½Π΅ΠΉ ΠΈΠ· ΡΠΈΡΠ°Π½Π° ΠΈ Π½ΠΈΠΊΠ΅Π»Ρ, ΠΏΠΎΠ»ΡΡΠ΅Π½Π½ΡΡ
Π½Π° ΠΏΠΎΠ²Π΅ΡΠΎΡΠ½ΠΎΠΉ ΡΡΡΠ°Π½ΠΎΠ²ΠΊΠ΅ Π½Π΅ΠΉΡΡΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ Π£ΠΠ-ΠΠ’140 Ρ ΡΠ΅Π»ΡΡ ΠΌΠ΅ΡΡΠΎΠ»ΠΎΠ³ΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΠΎΠ±Π΅ΡΠΏΠ΅ΡΠ΅Π½ΠΈΡ Π΄ΠΎΠ·ΠΈΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΡ
ΠΏΡΠΈΠ±ΠΎΡΠΎΠ² ΡΠ°Π΄ΠΈΠ°ΡΠΈΠΎΠ½Π½ΠΎΠΉ Π·Π°ΡΠΈΡΡ. ΠΠΎΠΊΠ°Π·Π°Π½Π° Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΡ ΠΏΡΠΎΠ²Π΅Π΄Π΅Π½ΠΈΡ ΠΊΠ°Π»ΠΈΠ±ΡΠΎΠ²ΠΊΠΈ Π΄ΠΎΠ·ΠΈΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΡ
ΠΏΡΠΈΠ±ΠΎΡΠΎΠ² Π² ΡΠ°ΠΊΠΈΡ
ΠΏΠΎΠ»ΡΡ
Π² ΡΠ°ΡΡΠΈΡΠ΅Π½Π½ΠΎΠΌ ΡΠ½Π΅ΡΠ³Π΅ΡΠΈΡΠ΅ΡΠΊΠΎΠΌ Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ Π΄ΠΎ 10 ΠΡΠ.
ΠΠΠΠ’ΠΠ¦ΠΠ― ΠΠΠͺΠΠΠΠ«Π₯ ΠΠΠ ΠΠΠ’ΠΠΠΠΠ‘Π’Π ΠΠΠ’ΠΠΠΠΠ
Due to the specific character of problems in the field of ionizing radiation spectroscopy, the R&D and making process of standard volumetric activity metal samples (standard samples) for calibration and verification of spectrometric equipment is not only expensive, but also requires the use of highly qualified experts and a unique specific equipment. Theoretical and experimental studies performed have shown the possibility to use imitators as a set of alternating point sources of gamma radiation and metal plates and their use along with standard volumetric activity metal samples for calibration of scintillation-based detectors used in radiation control in metallurgy. Response functions or instrumental spectra of such spectrometer to radionuclides like 137Cs, 134Cs, 152Eu, 154Eu, 60Co, 54Mn, 232Th, 226Ra, 65Zn, 125Sb+125mTe, 106Ru+106Rh, 94Nb, 110mAg, 233U, 234U, 235U and 238U are required for calibration in a given measurement geometry. Standard samples in the form of a probe made of melt metal of a certain diameter and height are used in such measurements. However, the production of reference materials is costly and even problematic for such radionuclides as 94Nb, 125Sb+125mTe, 234U, 235U Β etc. A recognized solution to solve this problem is to use the Monte-Carlo simulation method. Instrumental experimental and theoretical spectra obtained by using standard samples and their imitators show a high compliance between experimental spectra of real samples and the theoretical ones of their Monte-Carlo models, between spectra of real samples and the ones of their imitators and finally, between experimental spectra of real sample imitators and the theoretical ones of their Monte-Carlo models. They also have shown the adequacy and consistency of the approach in using a combination of metal scattering layers and reference point gamma-ray sources instead of standard volumetric activity metal samples. As for using several reference point gamma-ray sources with radionuclide like 152Eu, 232Th, 226Ra etc, they allow, in a combination of metal scattering layers, to compensate for the absorption of low energy gamma rays in the metal and to generate the desired response in the backscatter peak range, and finally to get the correct amplitude distribution that is equivalent to interaction effects that occur in the volumetric standard sample with radionuclide uniformly distributed in it.Β Π ΡΠ²ΡΠ·ΠΈ ΡΠΎ ΡΠΏΠ΅ΡΠΈΡΠΈΠΊΠΎΠΉ ΡΠ΅ΡΠ°Π΅ΠΌΡΡ
Π·Π°Π΄Π°Ρ Π² ΠΎΠ±Π»Π°ΡΡΠΈ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΠΈ ΠΈΠΎΠ½ΠΈΠ·ΠΈΡΡΡΡΠ΅Π³ΠΎ ΠΈΠ·Π»ΡΡΠ΅Π½ΠΈΡ ΠΏΡΠΎΡΠ΅ΡΡ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠΊΠΈ ΠΈ ΡΠΎΠ·Π΄Π°Π½ΠΈΡ ΠΎΠ±ΡΠ΅ΠΌΠ½ΡΡ
ΠΌΠ΅Ρ Π°ΠΊΡΠΈΠ²Π½ΠΎΡΡΠΈ (ΡΡΠ°Π½Π΄Π°ΡΡΠ½ΡΡ
ΠΎΠ±ΡΠ°Π·ΡΠΎΠ²) Π΄Π»Ρ ΠΊΠ°Π»ΠΈΠ±ΡΠΎΠ²ΠΊΠΈ, Π³ΡΠ°Π΄ΡΠΈΡΠΎΠ²ΠΊΠΈ ΠΈ ΠΏΠΎΠ²Π΅ΡΠΊΠΈ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΠΎΠ±ΠΎΡΡΠ΄ΠΎΠ²Π°Π½ΠΈΡ Π½Π΅ ΡΠΎΠ»ΡΠΊΠΎ ΡΠ²Π»ΡΠ΅ΡΡΡ Π΄ΠΎΡΠΎΠ³ΠΎΡΡΠΎΡΡΠΈΠΌ, Π½ΠΎ ΠΈ ΡΡΠ΅Π±ΡΠ΅Ρ ΠΏΡΠΈΠ²Π»Π΅ΡΠ΅Π½ΠΈΡ ΡΠΏΠ΅ΡΠΈΠ°Π»ΠΈΡΡΠΎΠ² Π²ΡΡΠΎΠΊΠΎΠΉ ΠΊΠ²Π°Π»ΠΈΡΠΈΠΊΠ°ΡΠΈΠΈ Ρ ΡΠ½ΠΈΠΊΠ°Π»ΡΠ½ΡΠΌ ΡΠΏΠ΅ΡΠΈΡΠΈΡΠ΅ΡΠΊΠΈΠΌ ΠΎΠ±ΠΎΡΡΠ΄ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ. Π‘ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ ΡΠ΅ΠΎΡΠ΅ΡΠΈΡΠ΅ΡΠΊΠΈΡ
ΠΈ ΡΠΊΡΠΏΠ΅ΡΠΈΠΌΠ΅Π½ΡΠ°Π»ΡΠ½ΡΡ
ΠΈΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΠΉ ΠΏΠΎΠΊΠ°Π·Π°Π½Π° Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΡ ΡΠΎΠ·Π΄Π°Π½ΠΈΡ ΠΈΠΌΠΈΡΠ°Π½ΡΠΎΠ² Π² Π²ΠΈΠ΄Π΅ Π½Π°Π±ΠΎΡΠ° ΡΠ΅ΡΠ΅Π΄ΡΡΡΠΈΡ
ΡΡ ΠΎΠ±ΡΠ°Π·ΡΠΎΠ²ΡΡ
ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΡ
Π³Π°ΠΌΠΌΠ°-ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠΎΠ² ΠΈ ΡΠ°ΡΡΠ΅ΠΈΠ²Π°ΡΠ΅Π»Π΅ΠΉ ΠΈ ΠΈΡ
ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΡ Π½Π°ΡΡΠ΄Ρ ΡΠΎ ΡΡΠ°Π½Π΄Π°ΡΡΠ½ΡΠΌΠΈ ΠΎΠ±ΡΠ°Π·ΡΠ°ΠΌΠΈ ΠΏΡΠΈ ΠΊΠ°Π»ΠΈΠ±ΡΠΎΠ²ΠΊΠ΅ ΠΈ ΠΏΠΎΠ²Π΅ΡΠΊΠ΅ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΎΠ² Π½Π° ΠΎΡΠ½ΠΎΠ²Π΅ ΡΡΠΈΠ½ΡΠΈΠ»Π»ΡΡΠΈΠΎΠ½Π½ΡΡ
Π΄Π΅ΡΠ΅ΠΊΡΠΎΡΠΎΠ², ΠΈΡΠΏΠΎΠ»ΡΠ·ΡΠ΅ΠΌΡΡ
ΠΏΡΠΈ ΡΠ°Π΄ΠΈΠ°ΡΠΈΠΎΠ½Π½ΠΎΠΌ ΠΊΠΎΠ½ΡΡΠΎΠ»Π΅ ΠΌΠ΅ΡΠ°Π»Π»ΠΎΠ². ΠΠ»Ρ Π³ΡΠ°Π΄ΡΠΈΡΠΎΠ²ΠΊΠΈ ΠΈ ΠΊΠ°Π»ΠΈΠ±ΡΠΎΠ²ΠΊΠΈ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΎΠ² ΡΡΠ΅Π±ΡΠ΅ΡΡΡ Π½Π°Π»ΠΈΡΠΈΠ΅ ΡΡΠ½ΠΊΡΠΈΠΉ ΠΎΡΠΊΠ»ΠΈΠΊΠ° ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠ° ΠΊ ΡΠ°ΠΊΠΈΠΌ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π°ΠΌ, ΠΊΠ°ΠΊ 137Cs, 134Cs, 152Eu, 154Eu, 60Co, 54Mn, 232Th, 226Ra, 65Zn, 125Sb+125mTe, 106Ru+106Rh, 94Nb, 110mAg, 233U, 234U, 235U ΠΈ 238U, ΠΏΡΠ΅Π΄ΡΡΠ°Π²Π»ΡΡΡΠΈΡ
ΡΠΎΠ±ΠΎΠΉ Π°ΠΏΠΏΠ°ΡΠ°ΡΡΡΠ½ΡΠ΅ ΡΠΏΠ΅ΠΊΡΡΡ Π² Π·Π°Π΄Π°Π½Π½ΠΎΠΉ Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΠΈ ΠΈΠ·ΠΌΠ΅ΡΠ΅Π½ΠΈΡ. ΠΠ»Ρ ΠΈΡ
ΠΏΠΎΠ»ΡΡΠ΅Π½ΠΈΡ ΠΈΡΠΏΠΎΠ»ΡΠ·ΡΡΡΡΡ ΡΡΠ°Π½Π΄Π°ΡΡΠ½ΡΠ΅ ΠΎΠ±ΡΠ°Π·ΡΡ, Π² Π²ΠΈΠ΄Π΅ ΠΏΡΠΎΠ±Ρ ΠΏΠ»Π°Π²ΠΊΠΈ ΠΌΠ΅ΡΠ°Π»Π»Π° ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½Π½ΠΎΠ³ΠΎ Π΄ΠΈΠ°ΠΌΠ΅ΡΡΠ° ΠΈ Π²ΡΡΠΎΡΡ. Π ΡΠ²ΠΎΡ ΠΎΡΠ΅ΡΠ΅Π΄Ρ ΠΈΠ·Π³ΠΎΡΠΎΠ²Π»Π΅Π½ΠΈΠ΅ ΡΡΠ°Π½Π΄Π°ΡΡΠ½ΡΡ
ΠΎΠ±ΡΠ°Π·ΡΠΎΠ² ΡΠ²Π»ΡΠ΅ΡΡΡ Π΄ΠΎΡΠΎΠ³ΠΎΡΡΠΎΡΡΠ΅ΠΉ ΠΏΡΠΎΡΠ΅Π΄ΡΡΠΎΠΉ, Π° Ρ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄Π°ΠΌΠΈ 94Nb, 125Sb+125mTe, 234U, 235U ΠΈ Ρ.Π΄. Π·Π°ΡΡΡΠ΄Π½ΠΈΡΠ΅Π»ΡΠ½ΠΎ. Π Π΄Π°Π½Π½ΠΎΠΌ ΡΠ»ΡΡΠ°Π΅ ΠΎΠ±ΡΠ΅ΠΏΡΠΈΠ·Π½Π°Π½Π½ΡΠΌ ΡΠ΅ΡΠ΅Π½ΠΈΠ΅ΠΌ ΡΠ°ΠΊΠΎΠΉ Π·Π°Π΄Π°ΡΠΈ ΡΠ²Π»ΡΠ΅ΡΡΡ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ ΠΌΠΎΠ΄Π΅Π»ΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΌΠ΅ΡΠΎΠ΄ΠΎΠΌ ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ. ΠΠΎΠ»ΡΡΠ΅Π½Π½ΡΠ΅ Ρ ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌ ΡΡΠ°Π½Π΄Π°ΡΡΠ½ΡΡ
ΠΎΠ±ΡΠ°Π·ΡΠΎΠ² ΠΈ ΠΈΡ
ΠΈΠΌΠΈΡΠ°Π½ΡΠΎΠ² ΡΠΊΡΠΏΠ΅ΡΠΈΠΌΠ΅Π½ΡΠ°Π»ΡΠ½ΡΠ΅ ΠΈ ΡΠ΅ΠΎΡΠ΅ΡΠΈΡΠ΅ΡΠΊΠΈΠ΅ Π°ΠΏΠΏΠ°ΡΠ°ΡΡΡΠ½ΡΠ΅ ΡΠΏΠ΅ΠΊΡΡΡ ΠΏΠΎΠΊΠ°Π·Π°Π»ΠΈ Π²ΡΡΠΎΠΊΠΎΠ΅ ΡΠΎΠΎΡΠ²Π΅ΡΡΡΠ²ΠΈΠ΅ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠ°Π½Π½ΡΡ
ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ ΠΌΠΎΠ΄Π΅Π»Π΅ΠΉ ΠΈΡ
ΡΠ΅Π°Π»ΡΠ½ΡΠΌ ΠΎΠ±ΡΠ°Π·ΡΠ°ΠΌ ΠΈ ΠΏΠΎΠ΄ΡΠ²Π΅ΡΠ΄ΠΈΠ»ΠΈ ΠΏΡΠ°Π²ΠΈΠ»ΡΠ½ΠΎΡΡΡ ΡΠ΅Π·ΡΠ»ΡΡΠ°ΡΠΎΠ² ΠΠΎΠ½ΡΠ΅-ΠΠ°ΡΠ»ΠΎ ΠΌΠΎΠ΄Π΅Π»ΠΈΡΠΎΠ²Π°Π½ΠΈΡ Π΄Π»Ρ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄ΠΎΠ² 110mAg, 154Eu, 232Th, 226Ra, 94Nb, 235U, 238U ΠΈ Ρ.Π΄., Π° ΡΠ°ΠΊΠΆΠ΅ ΠΏΠΎΠΊΠ°Π·Π°Π»ΠΈ Π°Π΄Π΅ΠΊΠ²Π°ΡΠ½ΠΎΡΡΡ ΠΈ ΡΠΎΡΡΠΎΡΡΠ΅Π»ΡΠ½ΠΎΡΡΡ ΠΏΠΎΠ΄Ρ
ΠΎΠ΄Π° Π² ΠΏΡΠΎΡΠ΅ΡΡΠ΅ ΠΈΠΌΠΈΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΡΡΠ°Π½Π΄Π°ΡΡΠ½ΡΡ
ΠΎΠ±ΡΠ°Π·ΡΠΎΠ² Ρ ΠΏΠΎΠΌΠΎΡΡΡ ΠΊΠΎΠΌΠ±ΠΈΠ½Π°ΡΠΈΠΈ ΡΠ°ΡΡΠ΅ΠΈΠ²Π°ΡΠ΅Π»Π΅ΠΉ ΠΈ ΠΎΠ±ΡΠ°Π·ΡΠΎΠ²ΡΡ
ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΡ
Π³Π°ΠΌΠΌΠ°-ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠΎΠ². ΠΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ Π½Π΅ΡΠΊΠΎΠ»ΡΠΊΠΈΡ
ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡΠ΅ΡΠΊΠΈΡ
Π³Π°ΠΌΠΌΠ°-ΠΈΡΡΠΎΡΠ½ΠΈΠΊΠΎΠ² Π² ΠΊΠΎΠΌΠ±ΠΈΠ½Π°ΡΠΈΠΈ Ρ Π½Π°Π±ΠΎΡΠΎΠΌ ΡΠ°ΡΡΠ΅ΠΈΠ²Π°ΡΠ΅Π»Π΅ΠΉ Π΄Π»Ρ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄ΠΎΠ² ΡΠΈΠΏΠ° 152Eu, 232Th, 226Ra ΠΈ Ρ.Π΄. ΠΏΠΎΠ·Π²ΠΎΠ»ΡΠ΅Ρ ΠΊΠΎΠΌΠΏΠ΅Π½ΡΠΈΡΠΎΠ²Π°ΡΡ ΠΏΠΎΠ³Π»ΠΎΡΠ΅Π½Π½ΡΠ΅ Π³Π°ΠΌΠΌΠ°-ΠΊΠ²Π°Π½ΡΡ Ρ Π½ΠΈΠ·ΠΊΠΈΠΌΠΈ ΡΠ½Π΅ΡΠ³ΠΈΡΠΌΠΈ Π² ΠΌΠ΅ΡΠ°Π»Π»Π΅, ΡΡΠΎΡΠΌΠΈΡΠΎΠ²Π°ΡΡ Π½Π΅ΠΎΠ±Ρ
ΠΎΠ΄ΠΈΠΌΡΠΉ ΠΎΡΠΊΠ»ΠΈΠΊ Π² ΠΎΠ±Π»Π°ΡΡΠΈ ΠΏΠΈΠΊΠ° ΠΎΠ±ΡΠ°ΡΠ½ΠΎΠ³ΠΎ ΡΠ°ΡΡΠ΅ΡΠ½ΠΈΡ ΠΈ Π² ΠΈΡΠΎΠ³Π΅ ΠΏΠΎΠ»ΡΡΠΈΡΡ Π°ΠΌΠΏΠ»ΠΈΡΡΠ΄Π½ΠΎΠ΅ ΡΠ°ΡΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΠ΅, ΡΠΊΠ²ΠΈΠ²Π°Π»Π΅Π½ΡΠ½ΠΎΠ΅ ΡΡΡΠ΅ΠΊΡΠ°ΠΌ Π²Π·Π°ΠΈΠΌΠΎΠ΄Π΅ΠΉΡΡΠ²ΠΈΡ, ΠΊΠΎΡΠΎΡΡΠ΅ ΠΏΡΠΎΠΈΡΡ
ΠΎΠ΄ΡΡ Π² ΡΡΠ°Π½Π΄Π°ΡΡΠ½ΠΎΠΌ ΠΎΠ±ΡΠ°Π·ΡΠ΅ Ρ ΡΠ°Π²Π½ΠΎΠΌΠ΅ΡΠ½ΠΎ ΡΠ°ΡΠΏΡΠ΅Π΄Π΅Π»Π΅Π½Π½ΡΠΌ ΠΏΠΎ ΠΎΠ±ΡΠ΅ΠΌΡ ΡΠ°Π΄ΠΈΠΎΠ½ΡΠΊΠ»ΠΈΠ΄ΠΎΠΌ.