1,769 research outputs found

    Resonances and Exclusive Channels: an Experimenter's Summary

    Get PDF
    A very remarkable number of new results in the study of resonances and exclusive channels has been presented at this conference giving fundamental information in the understanding of strong interactions at low energies. The first results from the new high luminosity colliders are impressive and a lot of activity in this field is foreseen for the future. The most relevant issues are summarized and discussed in this paper.Comment: Talk given at PHOTON 2001, Ascona, Switzerland, September 200

    Exclusive Channels in Photon-Photon Collisions at LEP

    Full text link
    The study of exclusive channels in photon-photon collisions at e+e- colliders allows to investigate the structure and the properties of hadrons in a very clean experimental environment. A concise review of the most recent results obtained at LEP is presented.Comment: Talk given at XXVIIth Rencontres de Moriond Les Arcs, France, March, 200

    Study of the KS0KS0K^{0}_{S}K^{0}_{S} Final State and the KS0K^{0}_{S} Inclusive Production in Two-Photon Collisions with the L3 Detector at LEP

    Get PDF
    The Ks0^0_sKs0^0_s final state in two-photon collisions is studied with the L3 detector at LEP using data collected at centre of mass energies from 91 GeV to 202 GeV. The mass spectrum is dominated by the formation of the f2'_2(1525) tensor meson in helicity two state. Clear evidence for destructive f2_2-a2_2 interference is observed. The first study of the fJ_J(1710) in two-photon collisions is presented. No signal has been observed in the region around 2.2 GeV and an upper limit for the two-photon partial width of the ξ\xi(2220) glueball candidate is derived. In the reaction \epem\rightarrow\epemhadrons the inclusive production of \kos mesons is studied using data collected by the L3 detector at LEP centre of mass energies from 189 to 202 GeV. The differential production cross sections as a function of the transverse momentum and of the pseudorapidity are measured and a reasonable agreement is found between our measurement and the Next-to-Leading order QCD predictions

    Present challenges in hadrontherapy techniques

    Get PDF
    Hadrontherapy is a high-precision technique in cancer radiation therapy, which allows obtaining a superior conformal treatment with respect to photons used in conventional radiation therapy. To reach this ambitious goal without reducing the patient throughput needed in a hospital-based environment, the physical and radiobiological properties of charged hadrons, protons and carbon ions in particular, have to be exploited at best, making use of the most modern technologies issued from research in nuclear and particle physics. In the present days, we are assisting to a continuous technological challenge, leading to the conception and to the development of innovative methods and instruments. In this paper, the most relevant challenges in dose delivery systems, gantries, imaging, quality assurance and particle accelerators are reviewe

    A system for online beam emittance measurements and proton beam characterization

    Full text link
    A system for online measurement of the transverse beam emittance was developed. It is named 4^{4}PrOBε\varepsilonaM (4-Profiler Online Beam Emittance Measurement) and was conceived to measure the emittance in a fast and efficient way using the multiple beam profiler method. The core of the system is constituted by four consecutive UniBEaM profilers, which are based on silica fibers passing across the beam. The 4^{4}PrOBε\varepsilonaM system was deployed for characterization studies of the 18~MeV proton beam produced by the IBA Cyclone 18 MeV cyclotron at Bern University Hospital (Inselspital). The machine serves daily radioisotope production and multi-disciplinary research, which is carried out with a specifically conceived Beam Transport Line (BTL). The transverse RMS beam emittance of the cyclotron was measured as a function of several machine parameters, such as the magnetic field, RF peak voltage, and azimuthal angle of the stripper. The beam emittance was also measured using the method based on the quadrupole strength variation. The results obtained with both techniques were compared and a good agreement was found. In order to characterize the longitudinal dynamics, the proton energy distribution was measured. For this purpose, a method was developed based on aluminum absorbers of different thicknesses, a UniBEaM detector, and a Faraday cup. The results were an input for a simulation of the BTL developed in the MAD-X software. This tool allows machine parameters to be tuned online and the beam characteristics to be optimized for specific applications.Comment: published in Journal of Instrumentatio

    An adjustable focusing system for a 2 MeV H- ion beam line based on permanent magnet quadrupoles

    Get PDF
    A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype is constructed and the magnetic field is measured, demonstrating good agreement with the simulation. Particle track simulations provide initial values for the quadrupole positions. Accordingly, four PMQs are constructed and assembled on the beam line, their positions are then tuned to obtain a minimal beam spot size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam line for an external ion beam. The novel compact design based on commercially available NdFeB magnets allows high flexibility for ion beam applications.Comment: published in JINST (4th Feb 2013

    Significant enhancement of irreversibility field in clean-limit bulk MgB2

    Full text link
    Low resistivity ("clean") MgB2 bulk samples annealed in Mg vapor show an increase in upper critical field Hc2(T) and irreversibility field Hirr(T) by a factor of 2 in both transport and magnetic measurements. The best sample displayed Hirr above 14 T at 4.2 K and 6 T at 20 K. These changes were accompanied by an increase of the 40 K resistivity from 1.0 to 18 microohm-cm and a lowering of the resistivity ratio from 15 to 3, while the critical temperature Tc decreased by only 1-2 K. These results point the way to make prepare MgB2 attractive for magnet applications.Comment: 3 pages, 4 figures, submitted to Applied Physics Letter

    Critical Field of MGB2 : Crossover from Clean to Dirty Regimes

    Full text link
    We have studied the upper critical field, Bc2, in poly-crystalline MgB2 samples in which disorder was varied in a controlled way to carry selectively p and s bands from clean to dirty limit. We have found that the clean regime survives when p bands are dirty and s bands are midway between clean and dirty. In this framework we can explain the anomalous behaviour of Al doped samples, in which Bc2 decreases as doping increases.Comment: 11 pages, 2 figure

    Ostracodes; witnesses of the Plio-Quaternary boundary in the North Eastern Atlantic preliminary results

    Get PDF
    Proceedings of the 1" R.C.A.N.S. Congress, Lisboa, October 1992The 2,4 MY crisis is an important event for the upper Neogene ofNorth Atlantic. A new climatic system occur and widespread during the Quaternary and is characterized by glacial and interglacial alternance. To follow the different steps of this crisis, we have choosen a borehole situated in the Cotentin peninsula (Normandy, France) and used ostracodes such as markers. The interpretation of quantitative and qualitative data from the ostracode fauna analysis shows that bathymetry was around 40 and 60 meters with slight fluctuations, excepted during Praetiglian event where the zone was outofwater. The morphologicalvariability analysis offour species (the best represented in the core), show a low variability between the basement and 80 meters. Beyond this limit and after 10 meters, characterized by very low values, the variability increases to very high values to the top of the core. Present data; Abe et Choe, 1988; Peypouquet et al, 1988; Carbonel et al., 1990 a, 1990 b; show that there is a close link between seasonal contrast intensity and ostracode intraspecifical morphological variations. The carbonates balance at the interface water / sediment, were ostracodes live and moult, is related and reflects the intensity of the seasonal contrast. After the Praetiglian event, an increase of the seasonal contrast occurs during the Tiglian A and the lower Tiglian B

    A beam monitor detector based on doped silica and optical fibres

    Full text link
    A beam monitor detector prototype based on doped silica fibres coupled to optical fibres has been designed, constructed and tested, mainly for accelerators used in medical applications. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam has been measured, giving information on beam position, shape and intensity. Mostly based on commercial components, the detector is easy to install, to operate and no electronic components are located near the beam. Tests have been performed with a 2 MeV proton pulsed beam at an average current of 0.8 {\mu}A. The response characteristics of Sb doped silica fibres have been studied for the first time
    corecore