100 research outputs found

    Role of semantic paradigms for optimization of language mapping in clinical FMRI studies.

    Get PDF
    BACKGROUND AND PURPOSE: The optimal paradigm choice for language mapping in clinical fMRI studies is challenging due to the variability in activation among different paradigms, the contribution to activation of cognitive processes other than language, and the difficulties in monitoring patient performance. In this study, we compared language localization and lateralization between 2 commonly used clinical language paradigms and 3 newly designed dual-choice semantic paradigms to define a streamlined and adequate language-mapping protocol. MATERIALS AND METHODS: Twelve healthy volunteers performed 5 language paradigms: Silent Word Generation, Sentence Completion, Visual Antonym Pair, Auditory Antonym Pair, and Noun-Verb Association. Group analysis was performed to assess statistically significant differences in fMRI percentage signal change and lateralization index among these paradigms in 5 ROIs: inferior frontal gyrus, superior frontal gyrus, middle frontal gyrus for expressive language activation, middle temporal gyrus, and superior temporal gyrus for receptive language activation. RESULTS: In the expressive ROIs, Silent Word Generation was the most robust and best lateralizing paradigm (greater percentage signal change and lateralization index than semantic paradigms at P P P P CONCLUSIONS: The combination of Silent Word Generation and ≥1 visual semantic paradigm, such as Sentence Completion and Noun-Verb Association, is adequate to determine language localization and lateralization; Noun-Verb Association has the additional advantage of objective monitoring of patient performance

    Echocardiography and pulse contour analysis to assess cardiac output in trauma patients.

    Get PDF
    Echocardiography is a valuable technique to assess cardiac output (CO) in trauma patients, but it does not allow a continuous bedside monitoring. Beat-to-beat CO assessment can be obtained by other techniques, including the pulse contour method MostCare. The aim of our study was to compare CO obtained with MostCare (MC-CO) with CO estimated by transthoracic echocardiography (TTE-CO) in trauma patients. METHODS: Forty-nine patients with blunt trauma admitted to an intensive care unit and requiring hemodynamic optimization within 24 hours from admission were studied. TTE-CO and MC-CO were estimated simultaneously at baseline, after a fluid challenge and after the start of vasoactive drug therapy. RESULTS: One hundred sixteen paired CO values were obtained. TTE-CO values ranged from 2.9 to 7.6 L·min-1, and MC-CO ranged from 2.8 to 8.2 L·min-1. The correlation between the two methods was 0.94 (95% confidence interval [CI] = 0.89 to 0.97; p<0.001). The mean bias was -0.06 L·min-1 with limits of agreements (LoA) of -0.94 to 0.82 L·min-1 (lower 95% CI, -1.16 to -0.72; upper 95% CI, 0.60 to 1.04) and a percentage error of 18%. Changes in CO showed a correlation of 0.91 (95% CI = 0.87 to 0.95; p<0.001), a mean bias of - 0.01 L·min-1 with LoA of -0.67 to 0.65 L·min-1 (lower 95% CI, -0.83 to -0.51; upper 95% CI, 0.48 to 0.81). CONCLUSION: CO measured by MostCare showed good agreement with CO obtained by transthoracic echocardiography. Pulse contour analysis can complement echocardiography in evaluating hemodynamics in trauma patients

    Hand-held echocardiography: added value in clinical cardiological assessment

    Get PDF
    BACKGROUND: The ultrasonic industry has recently produced echocardiographic Hand Held Devices (miniaturized, compact and battery-equipped echocardiographic systems). Their potential usefulness has been successfully assessed in a wide range of clinical conditions. The aim of the study was to verify if the routine use of a basic model of echocardiographic Hand Held Device (HHD) could be an important diagnostic tool during outpatient cardiologic consulting or in non-cardiologic hospital sections. METHODS: 87 consecutive patients were included in this study; they underwent routine physical examination, resting ECG and echocardiographic evaluation using a basic model of HHD performed by trained echocardiographists; the cardiologist, whenever possible, formulated a diagnosis. The percentage of subjects in whom the findings were judged reasonably adequate for final diagnostic and therapeutic conclusions was used to quantify the "conclusiveness" of HHD evaluation. Successively, all patients underwent a second echocardiographic evaluation, by an examiner with similar echocardiographic experience, performed using a Standard Echo Device (SED). The agreement between the first and the second echocardiographic exam was also assessed. RESULTS: Mean examination time was 6.7 ± 1.5 min. using HHD vs. 13.6 ± 2.4 min. using SED. The echocardiographic examination performed using HHD was considered satisfactory in 74/87 patients (85.1% conclusiveness). Among the 74 patients for whom the examination was conclusive, the diagnosis was concordant with that obtained with the SED examination in 62 cases (83.8% agreement). CONCLUSION: HHD may generally allow a reliable cardiologic basic evaluation of outpatient or subjects admitted to non-cardiologic sections, more specifically in particular subgroups of patients, with a gain in terms of time, shortening patient waiting lists and reducing healthy costs

    Acute effects of caffeine and cigarette smoking on ventricular long-axis function in healthy subjects

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Few data exist regarding the direct effects of caffeine and smoking on cardiac function. We sought to explore the acute effects of caffeine assumption, cigarette smoking, or both on left ventricular (LV) and right ventricular (RV) function in a population of young normal subjects.</p> <p>Methods</p> <p>Forty-five healthy subjects aged 25 ± 2 years underwent echocardiography. Fifteen of them were non-smokers and habitual coffee consumers (group 1), 15 were smokers and not habitual coffee consumers (group 2), and 15 were smokers and habitual coffee consumers (group 3). Peak systolic (S<sub>a</sub>), early diastolic E<sub>a</sub>, and late diastolic (A<sub>a</sub>) velocity of mitral annulus were measured by pulsed Tissue Doppler, and left atrioventricular plane displacement was determined by M-mode. Tricuspid annular velocities and systolic excursion (TAPSE) were also determined. Measurements were performed at baseline and after oral assumption of caffeine 100 mg in group 1, one cigarette smoking in group 2, and both in group 3.</p> <p>Results</p> <p>No changes in ventricular function were observed in group 1 after caffeine administration. In group 2, cigarette smoking yielded an acute increase in mitral A<sub>a </sub>(+12.1%, p = 0.0026), tricuspid S<sub>a </sub>(+9.8%, p = 0.012) and TAPSE (+7.9%, p = 0.017), and a decrease in the mitral E<sub>a</sub>/A<sub>a </sub>ratio (-8.5%, p = 0.0084). Sequential caffeine assumption and cigarette smoking in group 3 was associated with an acute increase in mitral A<sub>a </sub>(+13.0%, p = 0.015) and tricuspid A<sub>a </sub>(+11.6%, p < 0.0001) and a reduction in mitral E<sub>a</sub>/A<sub>a </sub>ratio (-8.5%, p = 0.0084) tricuspid E<sub>a </sub>(-6.6%, p = 0.048) and tricuspid E<sub>a</sub>/A<sub>a </sub>ratio (-9.6%, p = 0.0003). In a two-way ANOVA model controlling for hemodynamic confounding factors, changes in the overall population remained significant for mitral A<sub>a </sub>and E<sub>a</sub>/A<sub>a </sub>ratio, and for tricuspid A<sub>a </sub>and E<sub>a</sub>/A<sub>a </sub>ratio.</p> <p>Conclusion</p> <p>In young healthy subjects, one cigarette smoking is associated to an acute impairment in LV diastolic function and a hyperdynamic RV systolic response. Caffeine assumption alone does not exert any acute effect on ventricular long-axis function, but potentiates the negative effect of cigarette smoking by abolishing RV supernormal response and leading to a simultaneous impairment in both LV and RV diastolic function.</p

    Implications of serial measurements of natriuretic peptides in heart failure: insights from BIOSTAT‐CHF

    Get PDF
    No abstract available

    Real-time imaging of dissection of the ascending aorta.

    No full text
    Abstract We report the case of a 72-year-old woman referred for evaluation of a chest and back pain in whom we documented the dramatic progression from intramural hematoma to dissection of the ascending aorta with cardiac tamponade

    Late mitral annuloplasty failure: the loss of the ring.

    No full text
    Abstract An 81-year-old man complained with increasing dyspnoea and asthenia few months after a successful double mitral and tricuspid valvuloplasty intervention. The echocardiogram revealed a partial detachment of the mitral annuloplasty ring due to dehiscence determining a severe regurgitation. Curiously, at Color-Doppler analysis of mitral inflow, the prolapse of the detached ring produced a fascinating circular line inside the regurgitation signal, mimicking the shape of a gemstone ring. We described a case of a relatively uncommon cause of late mitral valvuloplasty failure characterized by a really unusual echocardiographic finding

    Early cardiac remodeling after repair of sinus venosus atrial septal defect.

    No full text
    We report the case of a 24-year-old man who underwent surgical repair of a sinus venosus atrial septal defect. Transthoracic echocardiograms performed on Day 3 and 6 after surgery demonstrated a very early cardiac remodeling with dramatic reduction of the right ventricular and atrial dimensions paralleled by an increase in the size of the left ventricle. This case provides the first demonstration of a very early cardiac remodeling after repair of sinus venosus atrial septal defect
    corecore