1,241 research outputs found
Comment on ``Lyapunov Exponent of a Many Body System and Its Transport Coefficients''
In a recent Letter, Barnett, Tajima, Nishihara, Ueshima and Furukawa obtained
a theoretical expression for the maximum Lyapunov exponent of a
dilute gas. They conclude that is proportional to the cube root of
the self-diffusion coefficient , independent of the range of the interaction
potential. They validate their conjecture with numerical data for a dense
one-component plasma, a system with long-range forces. We claim that their
result is highly non-generic. We show in the following that it does not apply
to a gas of hard spheres, neither in the dilute nor in the dense phase.Comment: 1 page, Revtex - 1 PS Figs - Submitted to Physical Review Letter
Ectopic cardiovascular fat in middle-aged men: effects of race/ethnicity, overall and central adiposity. The ERA JUMP study.
Background/objectivesHigher volumes of ectopic cardiovascular fat (ECF) are associated with greater risk of coronary heart disease (CHD). Identifying factors that are associated with ECF volumes may lead to new preventive efforts to reduce risk of CHD. Significant racial/ethnic differences exist for overall and central adiposity measures, which are known to be associated with ECF volumes. Whether racial/ethnic differences also exist for ECF volumes and their associations with these adiposity measures remain unclear.Subjects/methodsBody mass index (BMI), computerized tomography-measured ECF volumes (epicardial, pericardial and their summation) and visceral adipose tissue (VAT) were examined in a community-based sample of 1199 middle-aged men (24.2% Caucasians, 7.0% African-Americans, 23.6% Japanese-Americans, 22.0% Japanese, 23.2% Koreans).ResultsSignificant racial/ethnic differences existed in ECF volumes and their relationships with BMI and VAT. ECF volumes were the highest among Japanese-Americans and the lowest among African-Americans. The associations of BMI and VAT with ECF differed by racial/ethnic groups. Compared with Caucasians, for each 1-unit increase in BMI, African-Americans had lower, whereas Koreans had higher increases in ECF volumes (P-values<0.05 for both). Meanwhile, compared with Caucasians, for each 1-unit increase in log-transformed VAT, African-Americans, Japanese-Americans and Japanese had similar increases, whereas Koreans had a lower increase in ECF volumes (P-value<0.05).ConclusionsRacial/ethnic groups differed in their propensity to accumulate ECF at increasing level of overall and central adiposity. Future studies should evaluate whether reducing central adiposity or overall weight will decrease ECF volumes more in certain racial/ethnic groups. Evaluating these questions might help in designing race-specific prevention strategy of CHD risk associated with higher ECF
Measurement of the double-\beta decay half-life of ^{136}Xe with the KamLAND-Zen experiment
We present results from the KamLAND-Zen double-beta decay experiment based on
an exposure of 77.6 days with 129 kg of Xe. The measured two-neutrino
double-beta decay half-life of Xe is yr, consistent with a recent
measurement by EXO-200. We also obtain a lower limit for the neutrinoless
double-beta decay half-life, yr at 90%
confidence level (C.L.), which corresponds to almost a five-fold improvement
over previous limits.Comment: 6 pages, 4 figures. Version as published in PR
Scintillation-only Based Pulse Shape Discrimination for Nuclear and Electron Recoils in Liquid Xenon
In a dedicated test setup at the Kamioka Observatory we studied pulse shape
discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe
was based on the observation that scintillation light from electron events was
emitted over a longer period of time than that of nuclear recoil events, and
our method used a simple ratio of early to total scintillation light emission
in a single scintillation event. Requiring an efficiency of 50% for nuclear
recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2
0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee and to
7.7\pm2.8(stat)\pm2.5 2.8(sys)\times10-3 at energies between 9.6 and 12 keVee
for a scintillation light yield of 20.9 p.e./keV. Further study was done by
masking some of that light to reduce this yield to 4.6 p.e./keV, the same
method results in an electron event reduction of 2.4\pm0.2(stat)\pm0.3
0.2(sys)\times10-1 for the lower of the energy regions above. We also observe
that in contrast to nuclear recoils the fluctuations in our early to total
ratio for electron events are larger than expected from statistical
fluctuations.Comment: 25 pages, 15 figure
Multiphoton radiative recombination of electron assisted by laser field
In the presence of an intensive laser field the radiative recombination of
the continuum electron into an atomic bound state generally is accompanied by
absorption or emission of several laser quanta. The spectrum of emitted photons
represents an equidistant pattern with the spacing equal to the laser
frequency. The distribution of intensities in this spectrum is studied
employing the Keldysh-type approximation, i.e. neglecting interaction of the
impact electron with the atomic core in the initial continuum state. Within the
adiabatic approximation the scale of emitted photon frequencies is subdivided
into classically allowed and classically forbidden domains. The highest
intensities correspond to emission frequencies close to the edges of
classically allowed domain. The total cross section of electron recombination
summed over all emitted photon channels exhibits negligible dependence on the
laser field intensity.Comment: 14 pages, 5 figures (Figs.2-5 have "a" and "b" parts), Phys.Rev.A
accepted for publication. Fig.2b is presented correctl
White paper: CeLAND - Investigation of the reactor antineutrino anomaly with an intense 144Ce-144Pr antineutrino source in KamLAND
We propose to test for short baseline neutrino oscillations, implied by the
recent reevaluation of the reactor antineutrino flux and by anomalous results
from the gallium solar neutrino detectors. The test will consist of producing a
75 kCi 144Ce - 144Pr antineutrino source to be deployed in the Kamioka Liquid
Scintillator Anti-Neutrino Detector (KamLAND). KamLAND's 13m diameter target
volume provides a suitable environment to measure energy and position
dependence of the detected neutrino flux. A characteristic oscillation pattern
would be visible for a baseline of about 10 m or less, providing a very clean
signal of neutrino disappearance into a yet-unknown, "sterile" state. Such a
measurement will be free of any reactor-related uncertainties. After 1.5 years
of data taking the Reactor Antineutrino Anomaly parameter space will be tested
at > 95% C.L.Comment: White paper prepared for Snowmass-2013; slightly different author
lis
Self-shielding effect of a single phase liquid xenon detector for direct dark matter search
Liquid xenon is a suitable material for a dark matter search. For future
large scale experiments, single phase detectors are attractive due to their
simple configuration and scalability. However, in order to reduce backgrounds,
they need to fully rely on liquid xenon's self-shielding property. A prototype
detector was developed at Kamioka Observatory to establish vertex and energy
reconstruction methods and to demonstrate the self-shielding power against
gamma rays from outside of the detector. Sufficient self-shielding power for
future experiments was obtained.Comment: 8 pages, 8 figure
A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector
We describe a compact, ultra-clean device used to deploy radioactive sources
along the vertical axis of the KamLAND liquid-scintillator neutrino detector
for purposes of calibration. The device worked by paying out and reeling in
precise lengths of a hanging, small-gauge wire rope (cable); an assortment of
interchangeable radioactive sources could be attached to a weight at the end of
the cable. All components exposed to the radiopure liquid scintillator were
made of chemically compatible UHV-cleaned materials, primarily stainless steel,
in order to avoid contaminating or degrading the scintillator. To prevent radon
intrusion, the apparatus was enclosed in a hermetically sealed housing inside a
glove box, and both volumes were regularly flushed with purified nitrogen gas.
An infrared camera attached to the side of the housing permitted real-time
visual monitoring of the cable's motion, and the system was controlled via a
graphical user interface.Comment: Revised author affiliations, corrected typos, made minor improvements
to text, and revised reference
- …
