551 research outputs found
Comparison Between Ring and Radial Configurations of the University of Trieste Campus MV Distribution Grid
Distribution systems are being pushed towards smarter architectures, management strategies, and controls. To develop new platforms and algorithms for distribution systems management, the University of Trieste is using its medium voltage MW-scale ring distribution system as a demonstrator. In addition to the installation of a real-time monitoring system, power system studies and analyses are required. The paper presents and compares some results concerning the power system operation in both closed (normal operation) and open (post fault operation) configurations, where the latter are identified by means of a quantitative dependability analysis. In particular, the voltage profile, the currents, and the losses in the system are studied, evaluating the impact of faults capable of opening the ring
The Viscoelastic Properties of Passive Eye Muscle in Primates. III: Force Elicited by Natural Elongations
We have recently shown that in monkey passive extraocular muscles the force induced by a stretch does not depend on the entire length history, but to a great extent is only a function of the last elongation applied. This led us to conclude that Fung's quasi-linear viscoelastic (QLV) model, and more general nonlinear models based on a single convolution integral, cannot faithfully mimic passive eye muscles. Here we present additional data about the mechanical properties of passive eye muscles in deeply anesthetized monkeys. We show that, in addition to the aforementioned failures, previous models also grossly overestimate the force exerted by passive eye muscles during smooth elongations similar to those experienced during normal eye movements. Importantly, we also show that the force exerted by a muscle following an elongation is largely independent of the elongation itself, and it is mostly determined by the final muscle length. These additional findings conclusively rule out the use of classical viscoelastic models to mimic the mechanical properties of passive eye muscles. We describe here a new model that extends previous ones using principles derived from research on thixotropic materials. This model is able to account reasonably well for our data, and could thus be incorporated into models of the eye plant
Subtransmission overhead lines mechanical monitoring for fast detection of damaging events
Different harmful events affecting high voltage overhead lines (OHLs) cause changes in the mechanical tension (tensile strength) of conductors. A mechanical monitoring of OHLs, therefore, can provide useful additional information (compared with the information provided by the widely used SCADA systems) about the power system state. The tension measurements combined with a few environmental measurements (air temperature, wind speed) can be used for an automatic (fast) detection of different events and for their approximate location along an OHL, reducing the impact of these events. Referring to 132-150 kV sub-transmission OHLs, this paper proposes some original algorithms, based on the mechanical monitoring of OHLs, for the automatic detection of the following events: conductor breaking, fall of trees on the conductors, ice/snow sleeve accretion on the conductors, strands breaking and galloping. The proposed algorithms require a limited number of sensors placed along the OHLs for measurements of the conductor tension and weather-related quantities
First interferometric study of enhanced N-fractionation in NH: the high-mass star-forming region IRAS 05358+3543
Nitrogen (N) fractionation is used as a tool to search for a link between the
chemical history of the Solar System and star-forming regions. A large
variation of N/N is observed towards different astrophysical
sources, and current chemical models cannot reproduce it. With the advent of
high angular resolution radiotelescopes it is now possible to search for
N-fractionation at core scales. We present IRAM NOEMA observations of the J=1-0
transition of NH, NNH and NNNH towards
the high-mass protocluster IRAS 05358+3543. We find N/N ratios
that span from 100 up to 220 and these values are lower or equal
than those observed with single-dish observations towards the same source.
Since N-fractionation changes across the studied region, this means that it is
regulated by local environmental effects. We find also the possibility, for one
of the four cores defined in the protocluster, to have a more abundant
NNH with respect to NNNH. This is another indication
that current chemical models may be missing chemical reactions or may not take
into account other mechanisms, like photodissociation or grain surface
chemistry, that could be important.Comment: 19 pages, 8 figures, 6 tables, 3 appendices Accepted in Monthly
Notices of the Royal Astronomical Society Letter
Atrial dimension reference values in healthy participants using the biplane/monoplane method for clinical and research use
AIM: To provide reference values of the dimensions of the left and right atrium (RA) obtained using the biplane and monoplane methods, respectively, on two- and four-chamber views, which represent the standard projections acquired in clinical practice, and correlation with body surface area (BSA), age, and gender. MATERIALS AND METHODS: Healthy volunteers, M:F = 1:1, including five participants per gender and age decile from 20 to 70 years, who underwent cardiovascular magnetic resonance imaging (CMR) were enrolled prospectively. Normal atrial reference values were calculated for male and female subpopulations and stratified by age. Atrial areas and volumes were assessed both as absolute values and indexed to BSA. Differences among genders and correlation with age were assessed. Intra- and interobserver reproducibility were assessed in a subpopulation. RESULTS: Fifty participants (mean age 43.3 ± 14 years, 25 men) were evaluated. Image analysis took <1 minute for each subject (mean time 30 ± 5 seconds). Intra- and interobserver reproducibility were excellent (ICC >0.85 for all datasets). RA areas were significantly higher in males (p=0.0001). The left atrial (LA) surface did not show significant differences among genders. Atrial areas normalised to BSA did not show significant gender differences. Both right and left absolute atrial volumes turned out to be significantly higher in males (p=0.0001 and p=0.0047, respectively), and normalised to BSA remained significantly different only for the RA (p=0.0006). Neither atrial volume nor areas showed significant correlation with age. CONCLUSIONS: The monoplane method is a fast and reproducible technique to assess atrial dimensions. Absolute atrial dimensions show significant variations among genders. Gender-specific reference ranges for atrial dimensions are recommended
Medical Radiology: Current Progress
Recently, medical radiology has undergone significant improvements in patient management due to advancements in image acquisition by the last generation of machines, data processing, and the integration of artificial intelligence. In this way, cardiovascular imaging is one of the fastest-growing radiological subspecialties. In this study, a compressive review was focused on addressing how and why CT and MR have gained a I class indication in most cardiovascular diseases, and the potential impact of tissue and functional characterization by CT photon counting, quantitative MR mapping, and 4-D flow. Regarding rectal imaging, advances in cancer imaging using diffusion-weighted MRI sequences for identifying residual disease after neoadjuvant chemoradiotherapy and [18F] FDG PET/MRI were provided for high-resolution anatomical and functional data in oncological patients. The results present a large overview of the approach to the imaging of diffuse and focal liver diseases by US elastography, contrast-enhanced US, quantitative MRI, and CT for patient risk stratification. Italy is currently riding the wave of these improvements. The development of large networks will be crucial to create high-quality databases for patient-centered precision medicine using artificial intelligence. Dedicated radiologists with specific training and a close relationship with the referring clinicians will be essential human factors
Recommended from our members
Setting things straight: a comparison of measures of saccade trajectory deviation
In eye movements, saccade trajectory deviation has often been used as a physiological operationalization of visual attention, distraction, or the visual system’s prioritization of different sources of information. However, there are many ways to measure saccade trajectories and to quantify their deviation. This may lead to noncomparable results and poses the problem of choosing a method that will maximize statistical power. Using data from existing studies and from our own experiments, we used principal components analysis to carry out a systematic quantification of the relationships among eight different measures of saccade trajectory deviation and their power to detect the effects of experimental manipulations, as measured by standardized effect size. We concluded that (1) the saccade deviation measure is a good default measure of saccade trajectory deviation, because it is somewhat correlated with all other measures and shows relatively high effect sizes for two well-known experimental effects; (2) more generally, measures made relative to the position of the saccade target are more powerful; and (3) measures of deviation based on the early part of the saccade are made more stable when they are based on data from an eyetracker with a high sampling rate. Our recommendations may be of use to future eye movement researchers seeking to optimize the designs of their studies
Real time contrast enhanced ultrasonography in detection of liver metastases from gastrointestinal cancer
Background: Contrast enhanced ultrasound (CEUS) is an imaging technique which appeared on the market around the year 2000 and proposed for the detection of liver metastases in gastrointestinal cancer patients, a setting in which accurate staging plays a significant role in the choice of treatment. Methods: A total of 109 patients with colorectal (n = 92)or gastric cancer prospectively underwent computed tomography (CT) scan and conventional US evaluation followed by real time CEUS. A diagnosis of metastases was made by CT or, for lesions not visibile at CT, the diagnosis was achieved by histopathology or by a malignant behavior during follow-up. Results: Of 109 patients, 65 were found to have metastases at presentation. CEUS improved sensitivity in metastatic livers from 76.9% of patients (US) to 95.4% (p < 0.01), while CT scan reached 90.8% (p = n.s. vs CEUS, p < 0.01 vs US). CEUS and CT were more sensitive than US also for detection of single lesions (87 with US, 122 with CEUS, 113 with CT). In 15 patients (13.8%), CEUS revealed more metastases than CT, while CT revealed more metastases than CEUS in 9 patients (8.2%) (p = n.s.). Conclusion: CEUS is more sensitive than conventional US in the detection of liver metastases and could be usefully employed in the staging of patients with gastrointestinal cancer. Findings at CEUS and CT appear to be complementary in achieving maximum sensitivity. © 2007 Piscaglia et al; licensee BioMed Central Ltd
The Viscoelastic Properties of Passive Eye Muscle in Primates. I: Static Forces and Step Responses
The viscoelastic properties of passive eye muscles are prime determinants of the deficits observed following eye muscle paralysis, the root cause of several types of strabismus. Our limited knowledge about such properties is hindering the ability of eye plant models to assist in formulating a patient's diagnosis and prognosis. To investigate these properties we conducted an extensive in vivo study of the mechanics of passive eye muscles in deeply anesthetized and paralyzed monkeys. We describe here the static length-tension relationship and the transient forces elicited by small step-like elongations. We found that the static force increases nonlinearly with length, as previously shown. As expected, an elongation step induces a fast rise in force, followed by a prolonged decay. The time course of the decay is however considerably more complex than previously thought, indicating the presence of several relaxation processes, with time constants ranging from 1 ms to at least 40 s. The mechanical properties of passive eye muscles are thus similar to those of many other biological passive tissues. Eye plant models, which for lack of data had to rely on (erroneous) assumptions, will have to be updated to incorporate these properties
The Viscoelastic Properties of Passive Eye Muscle in Primates. II: Testing the Quasi-Linear Theory
We have extensively investigated the mechanical properties of passive eye muscles, in vivo, in anesthetized and paralyzed monkeys. The complexity inherent in rheological measurements makes it desirable to present the results in terms of a mathematical model. Because Fung's quasi-linear viscoelastic (QLV) model has been particularly successful in capturing the viscoelastic properties of passive biological tissues, here we analyze this dataset within the framework of Fung's theory
- …