    Estimation of coronary artery hyperemic blood flow based on arterial lumen volume using angiographic images

    Get PDF
    The purpose of this study is to develop a method to estimate the hyperemic blood flow in a coronary artery using the sum of the distal lumen volumes in a swine animal model. The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions where it is difficult to determine whether a particular lesion is the cause of ischemia. Therefore, a functional measure of stenosis severity is needed using angiographic image data. Coronary arteriography was performed in 10 swine (Yorkshire, 25–35 kg) after power injection of contrast material into the left main coronary artery. A densitometry technique was used to quantify regional flow and lumen volume in vivo after inducing hyperemia. Additionally, 3 swine hearts were casted and imaged post-mortem using cone-beam CT to obtain the lumen volume and the arterial length of corresponding coronary arteries. Using densitometry, the results showed that the stem hyperemic flow (Q) and the associated crown lumen volume (V) were related by Q = 159.08 V3/4 (r = 0.98, SEE = 10.59 ml/min). The stem hyperemic flow and the associated crown length (L) using cone-beam CT were related by Q = 2.89 L (r = 0.99, SEE = 8.72 ml/min). These results indicate that measured arterial branch lengths or lumen volumes can potentially be used to predict the expected hyperemic flow in an arterial tree. This, in conjunction with measured hyperemic flow in the presence of a stenosis, could be used to predict fractional flow reserve based entirely on angiographic data

    Quantification of fractional flow reserve based on angiographic image data

    Get PDF
    Coronary angiography provides excellent visualization of coronary arteries, but has limitations in assessing the clinical significance of a coronary stenosis. Fractional flow reserve (FFR) has been shown to be reliable in discerning stenoses responsible for inducible ischemia. The purpose of this study is to validate a technique for FFR quantification using angiographic image data. The study was carried out on 10 anesthetized, closed-chest swine using angioplasty balloon catheters to produce partial occlusion. Angiography based FFR was calculated from an angiographically measured ratio of coronary blood flow to arterial lumen volume. Pressure-based FFR was measured from a ratio of distal coronary pressure to aortic pressure. Pressure-wire measurements of FFR (FFRP) correlated linearly with angiographic volume-derived measurements of FFR (FFRV) according to the equation: FFRP = 0.41 FFRV + 0.52 (P-value < 0.001). The correlation coefficient and standard error of estimate were 0.85 and 0.07, respectively. This is the first study to provide an angiographic method to quantify FFR in swine. Angiographic FFR can potentially provide an assessment of the physiological severity of a coronary stenosis during routine diagnostic cardiac catheterization without a need to cross a stenosis with a pressure-wire

    Quantification of breast density using dual-energy mammography with liquid phantom calibration

    Full text link
    Breast density is a widely recognized potential risk factor for breast cancer. However, accurate quantification of breast density is a challenging task in mammography. The current use of plastic breast-equivalent phantoms for calibration provides limited accuracy in dual-energy mammography due to the chemical composition of the phantom. We implemented a breast-equivalent liquid phantom for dual-energy calibration in order to improve the accuracy of breast density measurement. To design these phantoms, three liquid compounds were chosen: water, isopropyl alcohol, and glycerol. Chemical compositions of glandular and adipose tissues, obtained from NIST database, were used as reference materials. Dual-energy signal of the liquid phantom at different breast densities (0% to 100%) and thicknesses (1 to 8 cm) were simulated. Glandular and adipose tissue thicknesses were estimated from a higher order polynomial of the signals. Our results indicated that the linear attenuation coefficients of the breast-equivalent liquid phantoms match those of the target material. Comparison between measured and known breast density data shows a linear correlation with a slope close to 1 and a non-zero intercept of 7%, while plastic phantoms showed a slope of 0.6 and a non-zero intercept of 8%. Breast density results derived from the liquid calibration phantoms showed higher accuracy than those derived from the plastic phantoms for different breast thicknesses and various tube voltages. We performed experimental phantom studies using liquid phantoms and then compared the computed breast density with those obtained using a bovine tissue model. The experimental data and the known values were in good correlation with a slope close to 1 (∼1.1). In conclusion, our results indicate that liquid phantoms are a reliable alternative for calibration in dual-energy mammography and better reproduce the chemical properties of the target material

    Quantification of coronary microvascular resistance using angiographic images for volumetric blood flow measurement: in vivo validation

    No full text
    Structural coronary microcirculation abnormalities are important prognostic determinants in clinical settings. However, an assessment of microvascular resistance (MR) requires a velocity wire. A first-pass distribution analysis technique to measure volumetric blood flow has been previously validated. The aim of this study was the in vivo validation of the MR measurement technique using first-pass distribution analysis. Twelve anesthetized swine were instrumented with a transit-time ultrasound flow probe on the proximal segment of the left anterior descending coronary artery (LAD). Microspheres were injected into the LAD to create a model of microvascular dysfunction. Adenosine (400 μg·kg−1·min−1) was used to produce maximum hyperemia. A region of interest in the LAD arterial bed was drawn to generate time-density curves using angiographic images. Volumetric blood flow measurements (Qa) were made using a time-density curve and the assumption that blood was momentarily replaced with contrast agent during the injection. Blood flow from the flow probe (Qp), coronary pressure (Pa), and right atrium pressure (Pv) were continuously recorded. Flow probe-based normalized MR (NMRp) and angiography-based normalized MR (NMRa) were calculated using Qp and Qa, respectively. In 258 measurements, Qa showed a strong correlation with the gold standard Qp (Qa = 0.90 Qp + 6.6 ml/min, r2 = 0.91, P < 0.0001). NMRa correlated linearly with NMRp (NMRa = 0.90 NMRp + 0.02 mmHg·ml−1·min−1, r2 = 0.91, P < 0.0001). Additionally, the Bland-Altman analysis showed a close agreement between NMRa and NMRp. In conclusion, a technique based on angiographic image data for quantifying NMR was validated using a swine model. This study provides a method to measure NMR without using a velocity wire, which can potentially be used to evaluate microvascular conditions during coronary arteriography