148 research outputs found

    Association of Operator and Hospital Experience With Procedural Success Rates and Outcomes in Patients Undergoing Percutaneous Coronary Interventions for Chronic Total Occlusions: Insights From the Blue Cross Blue Shield of Michigan Cardiovascular Consortium

    Get PDF
    BACKGROUND: An inverse relationship has been described between procedural success and outcomes of all major cardiovascular procedures. However, this relationship has not been studied for percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). METHODS: We analyzed the data on patients enrolled in Blue Cross Blue Shield of Michigan Cardiovascular Consortium registry in Michigan (January 1, 2010 to March 31, 2018) to evaluate the association of operator and hospital experience with procedural success and outcomes of patients undergoing CTO-PCI. CTO-PCI was defined as intervention of a 100% occluded coronary artery presumed to be ≥3 months old. RESULTS: Among 210 172 patients enrolled in the registry, 7389 (3.5%) CTO-PCIs were attempted with a success rate of 53%. CTO-PCI success increased with operator experience (45% and 65% in the lowest and highest experience tertiles) and was the highest for highly experienced operators at higher experience centers and the lowest for inexperienced operators at low experience hospitals. Multivariable logistic regression models (with spline transformed prior operator and institutional experience) demonstrated a positive relationship between prior operator and site experience and procedural success rates (likelihood ratio test=141.12, df=15, P\u3c0.001) but no relationship between operator and site experience and major adverse cardiac event (likelihood ratio test=19.12, df=15, P=0.208). CONCLUSIONS: Operator and hospital CTO-PCI experiences were directly related to procedural success but were not related to major adverse cardiac event among patients undergoing CTO-PCIs. Inexperienced operators at high experience centers had significantly higher success but not major adverse cardiac event rates compared with inexperienced operators at low experience centers. These data suggested that CTO-PCI safety and success could potentially be improved by selective referral of these procedures to experienced operators working at highly experienced centers

    The initial U.S. experience with the Tempo active fixation temporary pacing lead in structural heart interventions

    Full text link
    ObjectivesThis multicenter retrospective study of the initial U.S. experience evaluated the safety and efficacy of temporary cardiac pacing with the Tempo® Temporary Pacing Lead.BackgroundDespite increasing use of temporary cardiac pacing with the rapid growth of structural heart procedures, temporary pacing leads have not significantly improved. The Tempo lead is a new temporary pacing lead with a soft tip intended to minimize the risk of perforation and a novel active fixation mechanism designed to enhance lead stability.MethodsData from 269 consecutive structural heart procedures were collected. Outcomes included device safety (absence of clinically significant cardiac perforation, new pericardial effusion, or sustained ventricular arrhythmia) and efficacy (clinically acceptable pacing thresholds with successful pace capture throughout the index procedure). Postprocedure practices and sustained lead performance were also analyzed.ResultsThe Tempo lead was successfully positioned in the right ventricle and achieved pacing in 264 of 269 patients (98.1%). Two patients (0.8%) experienced loss of pace capture. Procedural mean pace capture threshold (PCT) was 0.7 ± 0.8 mA. There were no clinically significant perforations, pericardial effusions, or sustained device‐related arrhythmias. The Tempo lead was left in place postprocedure in 189 patients (71.6%) for mean duration of 43.3 ± 0.7 hr (range 2.5–221.3 hr) with final PCT of 0.84 ± 1.04 mA (n = 80). Of these patients, 84.1% mobilized out of bed with no lead dislodgment.ConclusionThe Tempo lead is safe and effective for temporary cardiac pacing for structural heart procedures, provides stable peri and postprocedural pacing and allows mobilization of patients who require temporary pacing leads.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/154941/1/ccd28476.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/154941/2/ccd28476_am.pd

    Social disparities in the use of colonoscopy by primary care physicians in Ontario

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>It is unclear if all persons in Ontario have equal access to colonoscopy. This research was designed to describe long-term trends in the use of colonoscopy by primary care physicians (PCPs) in Ontario, and to determine whether PCP characteristics influence the use of colonoscopy.</p> <p>Methods</p> <p>We conducted a population-based retrospective study of PCPs in Ontario between the years 1996-2005. Using administrative data we identified a screen-eligible group of patients aged 50-74 years in Ontario. These patients were linked to the PCP who provided the most continuous care to them during each year. We determined the use of any colonoscopy among these patients. We calculated the rate of colonoscopy for each PCP as the number of patients undergoing colonoscopies per 100 screen eligible patients. Negative binomial regression was used to identify factors associated with the rate of colonoscopy, using generalized estimating equations to account for clustering of patients within PCPs.</p> <p>Results</p> <p>Between 7,955 and 8,419 PCPs in Ontario per year (median age 43 years) had at least 10 eligible patients in their practices. The use of colonoscopy by PCPs increased sharply in Ontario during the study period, from a median rate of 1.51 [inter quartile range (IQR) 0.57-2.62] per 100 screen eligible patients in 1996 to 4.71 (IQR 2.70-7.53) in 2005. There was substantial variation between PCPs in their use of colonoscopy. PCPs who were Canadian medical graduates and with more years of experience were more likely to use colonoscopy after adjusting for their patient characteristics. PCPs were more likely to use colonoscopy if their patient populations were predominantly women, older, had more illnesses, and if their patients resided in less marginalized neighborhoods (lower unemployment, fewer immigrants, higher income, higher education, and higher English/French fluency).</p> <p>Conclusions</p> <p>There is substantial variation in the use of colonoscopy by PCPs, and this variation has increased as the overall use of colonoscopy increased over time. PCPs whose patients were more marginalized were less likely to use colonoscopy, suggesting that there are inequities in access.</p

    Effective and safe proton pump inhibitor therapy in acid-related diseases – A position paper addressing benefits and potential harms of acid suppression

    Full text link

    Transposition of the yeast retroviruslike element Ty3 is dependent on the cell cycle.

    No full text
    Host cell cycle genes provide important functions to retroviruses and retroviruslike elements. To define some of these functions, the cell cycle dependence of transposition of the yeast retroviruslike element Ty3 was examined. Ty3 is unique among retroviruslike elements because of the specificity of its integration, which occurs upstream of genes transcribed by RNA polymerase III. A physical assay for Ty3 transposition which takes advantage of this position-specific integration was developed. The assay uses PCR to amplify a product of Ty3 integration into a target plasmid that carries a modified tRNA gene. By using the GAL1 upstream activating sequence to regulate expression of Ty3, transposition was detected within one generation of cell growth after Ty3 transcription was initiated. This physical assay was used to show that Ty3 did not transpose when yeast cells were arrested in G1 during treatment with the mating pheromone alpha-factor. The restriction of transposition was not due to changes in transcription of either Ty3 or tRNA genes or to aspects of the mating pheromone response unrelated to cell cycle arrest. The block of the Ty3 life cycle was reversed when cells were released from G1 arrest. Examination of Ty3 intermediates during G1 arrest indicated that Ty3 viruslike particles were present but that reverse transcription of the Ty3 genomic RNA into double-stranded DNA had not occurred. In G1, the Ty3 life cycle is blocked after particle assembly but before the completion of reverse transcription
    corecore