302 research outputs found

    LANDSAT (ERTS) used as a basis for geological volcanological mapping in the central Andes

    Get PDF
    LANDSAT images of the central Andes (N-Chile, W-Bolivia) were effectively used for volcanological mapping of an area about 160,000 km. The map shown exhibits more and better details than the older small scale geological maps of that area. Even on a scale of 1:1,000,000 details greater than 200 m in size are recognizable. The interpretation of LANDSAT images makes it possible to establish relative age sequences of strato-volcanoes. Finally, the images will also be helpful in prospecting for mineral deposits and geothermal sources

    Volcanism subprogram: Volcanological interpretation of the northern part of the Occidental Cordillera of Bolivia, utilizing ERTS imagery

    Get PDF
    The author has identified the following significant results. In the present study, 6 ERTS-1 images have been interpreted on a 1:1 million scale (black and white) with the respective field reconnaissance. The area studied is located in the region bordering with Chile and includes the western part of the Bolivian Altiplano, the volcano Cordillera (western cordillera) and the northern part of Chile to the Pacific Coast. The greater part of this region is formed by Pliocene/Pleistocene volcani rock, which is discordant with the Tertiary sediments with intercalations of calcareous tuff. The ERTS-1 imagery permits the tracing of regional boundaries of the great volcanic formations and the alinements of the volcanic bodies along the fault zones. They also permit a clear examination of the volcanic apparatus, including their secondary forms, such as lava flows, parasitic cones, and lava domes. Because of the great scale, it is not possible to identify either the small structures or those of low relief. On the basis of the interpretation of the images, it is possible to give an idea of the relative age of the volcanoes

    Optical and scratch resistant properties of diamondlike carbon films deposited with single and dual ion beams

    Get PDF
    Amorphous diamondlike carbon (DLC) films were deposited using both single and dual ion beam techniques utilizing filament and hollow cathode ion sources. Continuous DLC films up to 3000 A thick were deposited on fused quartz plates. Ion beam process parameters were varied in an effort to create hard, clear films. Total DLC film absorption over visible wavelengths was obtained using a Perkin-Elmer spectrophotometer. An ellipsometer, with an Ar-He laser (wavelength 6328 A) was used to determine index of refraction for the DLC films. Scratch resistance and frictional and adherence properties were determined for select films. Applications for these films range from military to the ophthalmic industries

    Dual ion beam processed diamondlike films for industrial applications

    Get PDF
    Single and dual beam ion source systems are used to generate amorphous diamondlike carbon (DLC) films, which were evaluated for a variety of applications including protective coatings on transmitting materials, power electronics as insulated gates and corrosion resistant barriers. A list of the desirable properties of DLC films along with potential applications are presented

    The 2.3 kW Ion Thruster Wear Test

    Get PDF
    A 30-cm diameter xenon ion thruster is under development at NASA to provide an ion propulsion option for auxiliary and primary propulsion on missions of national interest. Specific efforts include thruster design optimizations, component life testing and validation, and performance characterizations. Under this program, the ion thruster will be brought to engineering model development status. This paper describes the results of a 2.3-kW 2000-hour wear test performed to identify life limiting phenomena, measure the performance and characterize the operation of the thruster, and obtain wear, erosion, and surface contamination data. These data are being using as a data base for proceeding with additional life validation tests, and to provide input to flight thruster design requirements

    Suppression of 2D superconductivity by the magnetic field: quantum corrections vs superconductor-insulator transition

    Full text link
    Magnetotransport of superconducting Nd_{2-x}Ce_xCuO_{4+y} (NdCeCuO) films is studied in the temperature interval 0.3-30 K. The microscopic theory of the quantum corrections to conductivity, both in the Cooper and in the diffusion channels, qualitatively describes the main features of the experiment including the negative magnetoresistance in the high field limit. Comparison with the model of the field-induced superconductor-insulator transition (SIT) is included and a crossover between these two theoretical approaches is discussed.Comment: 5 pages, 4 figures. Submitted to JETP Letter

    Two-dimensional quantum interference contributions to the magnetoresistance of Nd{2-x}Ce{x}CuO{4-d} single crystals

    Full text link
    The 2D weak localization effects at low temperatures T = (0.2-4.2)K have been investigated in nonsuperconducting sample Nd{1.88}Ce{0.12}CuO{4-d} and in the normal state of the superconducting sample Nd{1.82}Ce{0.18}CuO{4-d} for B>B_c2. The phase coherence time and the effective thickness dd of a conducting CuO_2 layer have been estimated by the fitting of 2D weak localization theory expressions to the magnetoresistivity data for the normal to plane and the in-plane magnetic fields.Comment: 5 pages, 4 postscript figure

    Development Status of the NASA 30-cm Ion Thruster and Power Processor

    Get PDF
    Xenon ion propulsion systems are being developed by NASA Lewis Research Center and the Jet Propulsion Laboratory to provide flight qualification and validation for planetary and earth-orbital missions. In the ground-test element of this program, light-weight (less than 7 kg), 30 cm diameter ion thrusters have been fabricated, and preliminary design verification tests have been conducted. At 2.3 kW, the thrust, specific impulse, and efficiency were 91 mN, 3300 s, and 0.65, respectively. An engineering model thruster is now undergoing a 2000 h wear-test. A breadboard power processor is being developed to operate from an 80 V to 120 V power bus with inverter switching frequencies of 50 kHz. The power processor design is a pathfinder and uses only three power supplies. The projected specific mass of a flight unit is about 5 kg/kW with an efficiency of 0.92 at the full-power of 2.5 kW. Preliminary integration tests of the neutralizer power supply and the ion thruster have been completed. Fabrication and test of the discharge and beam/accelerator power stages are underway

    The Impact of Medical Interpretation Method on Time and Errors

    Get PDF
    Background: Twenty-two million Americans have limited English proficiency. Interpreting for limited English proficient patients is intended to enhance communication and delivery of quality medical care. Objective: Little is known about the impact of various interpreting methods on interpreting speed and errors. This investigation addresses this important gap. Design: Four scripted clinical encounters were used to enable the comparison of equivalent clinical content. These scripts were run across four interpreting methods, including remote simultaneous, remote consecutive, proximate consecutive, and proximate ad hoc interpreting. The first 3 methods utilized professional, trained interpreters, whereas the ad hoc method utilized untrained staff. Measurements: Audiotaped transcripts of the encounters were coded, using a prespecified algorithm to determine medical error and linguistic error, by coders blinded to the interpreting method. Encounters were also timed. Results: Remote simultaneous medical interpreting (RSMI) encounters averaged 12.72 vs 18.24 minutes for the next fastest mode (proximate ad hoc) (p = 0.002). There were 12 times more medical errors of moderate or greater clinical significance among utterances in non-RSMI encounters compared to RSMI encounters (p = 0.0002). Conclusions: Whereas limited by the small number of interpreters involved, our study found that RSMI resulted in fewer medical errors and was faster than non-RSMI methods of interpreting
    • …
    corecore