21 research outputs found

    Clinical Experience with the PillCam Patency Capsule prior to Video Capsule Endoscopy: A Real-World Experience

    Get PDF
    Background. In patients with known or suspected risk factors for gastrointestinal stenosis, the PillCam patency capsule (PC) is given before a video capsule endoscopy (VCE) in order to minimize the risk of capsule retention (CR). CR is considered unlikely upon excretion of the PC within 30 hours, excretion in an undamaged state after 30 hours, or radiological projection to the colon. Methods. We performed a retrospective analysis of 38 patients with risk factors for CR, who received a PC from 02/2013 to 04/2015 at Klinikum Augsburg. Results. Sixteen of our 38 patients observed a natural excretion after a mean time of 34 hours past ingestion. However, only 8 patients observed excretion within 30 hours, as recommended by the company. In 20 patients passage of the PC into the colon was shown via RFID-scan or radiological imaging (after 33 and 45 hours, resp.). Only 2 patients showed a pathologic PC result. In consequence, 32 patients received the VCE; no CR was observed. Conclusion. Our data indicates that a VCE could safely be performed even if the PC excretion time is longer than 30 hours and the excreted PC was not screened for damage

    Clinical Study Clinical Experience with the PillCam Patency Capsule prior to Video Capsule Endoscopy: A Real-World Experience

    Get PDF
    Background. In patients with known or suspected risk factors for gastrointestinal stenosis, the PillCam patency capsule (PC) is given before a video capsule endoscopy (VCE) in order to minimize the risk of capsule retention (CR). CR is considered unlikely upon excretion of the PC within 30 hours, excretion in an undamaged state after 30 hours, or radiological projection to the colon. Methods. We performed a retrospective analysis of 38 patients with risk factors for CR, who received a PC from 02/2013 to 04/2015 at Klinikum Augsburg. Results. Sixteen of our 38 patients observed a natural excretion after a mean time of 34 hours past ingestion. However, only 8 patients observed excretion within 30 hours, as recommended by the company. In 20 patients passage of the PC into the colon was shown via RFID-scan or radiological imaging (after 33 and 45 hours, resp.). Only 2 patients showed a pathologic PC result. In consequence, 32 patients received the VCE; no CR was observed. Conclusion. Our data indicates that a VCE could safely be performed even if the PC excretion time is longer than 30 hours and the excreted PC was not screened for damage

    Detection Rate and Clinical Relevance of Ink Tattooing during Balloon-Assisted Enteroscopy

    Get PDF
    Background and Aims. Balloon-assisted enteroscopy (BAE) is a well-established tool in the diagnosis and therapy of small bowel diseases. Ink tattooing of the small bowel is used to mark pathologic lesions or the depth of small bowel insertion. The purpose of this study was to determine the safety, the detection rate, and the clinical relevance of ink tattooing during BAE. Methods. We performed a retrospective analysis of all 81 patients who received an ink tattooing during BAE between 2010 and 2015. Results. In all patients, ink tattooing was performed with no complications. 26 patients received a capsule endoscopy after BAE. The tattoo could be detected via capsule endoscopy in 19 of these 26 patients. The tattoo of the previous BAE could be detected via opposite BAE in 2 of 11 patients. In 9 patients, ink tattooing influenced the choice of approach for reenteroscopy. In 7 patients, the tattoo was used for intraoperative localization and in 3 patients for intraoperative localization as well as for reenteroscopy. The intraoperative detection rate of the tattoo was 100%. Conclusion. Ink tattooing of the small intestine is a safe endoscopic procedure to mark the depth of scope insertion or a pathologic lesion during balloon-assisted enteroscopy

    Use of anticoagulation during wireless capsule endoscopy for the investigation of recurrent obscure gastrointestinal bleeding

    No full text
    Detecting the source of obscure gastrointestinal bleeding can be difficult. Capsule endoscopy is a promising diagnostic tool for investigating patients with this condition, although identifying the source of intermittent or low-grade bleeding remains a diagnostic challenge. We present case reports of two patients with obscure gastrointestinal bleeding, in whom the source of recurrent bleeding episodes was diagnosed by capsule endoscopy while they were on anticoagulation therapy. The first patient, an 81-year-old white woman, was on long-term oral anticoagulation because she had chronic atrial fibrillation. Capsule endoscopy demonstrated a bleeding tumor in the region of the terminal ileum. The second patient, a 59-year-old white man, underwent an initial capsule endoscopy, which was negative. After initiation of anticoagulation with heparin, a second capsule endoscopy procedure in this patient revealed several small bleeding lesions in the proximal small bowel. In both cases a gastrointestinal stromal tumor was identified as the bleeding source and was resected. These two cases demonstrate that provocation of bleeding during capsule endoscopy may increase its sensitivity

    Modified endoscopic mucosal resection techniques for treating precancerous colorectal lesions

    No full text
    Endoscopic mucosal resection (EMR) is a technique allowing efficacious and minimally invasive resection of precancerous lesions across the entire gastrointestinal tract. However, conventional EMR, involving injection of fluid into the submucosal space, is imperfect, given the high rate of recurrence of post-endoscopic resection adenoma, especially after piecemeal resection. In light of these observations, modifications of the technique have been proposed to overcome the weakness of conventional EMR. Some of them were designed to maximize the chance of en bloc resection—cap-assisted EMR, underwater EMR, tip-in EMR, precutting, assisted by ligation device—while others were designed to minimize the complications (cold EMR). In this review, we present their modes of action and summarize the evidence regarding their efficacy and safety
    corecore