1,395 research outputs found

    Full Digital Workflow for Prosthetic Full-Arch Immediate Loading Rehabilitation Using OT-Bridge System: A Case Report

    Get PDF
    Nowadays, digital technologies have brought very important advancements in clinical prosthetic dentistry. However, a full digital workflow is still considered to be challenging in the management of full-arch implant cases with immediate prosthetic loading. The aim of this case report is to show a full-digital workflow for the fabrication of an implant-prosthetic fixed provisional prosthesis for immediate loading on seven implants in the upper maxilla. The static guided implant surgery and the OT Bridge prosthetic system were used to rehabilitate the patient. In this way, the combination of a well-known surgical technique with a peculiar prosthetic system that allows for a certain degree of tolerance resulted in it being useful for full-arch immediate loading. Future research and studies are necessary to prove the reliability of this full-digital protocol

    The New Elderly Patient: A Necessary Upgrade

    Get PDF
    The elderly individual is becoming the most common patient in clinical practice due to the increasing average life span, especially in developed countries. The current elderly patients are different from those of some decades ago. They usually have an active social life, want to be informed, and are actively involved in the current society with consequent high expectations for medical and dental treatment. However, not all the elderly patients are like this. Some of them show limited financial resources, reduced mental and manual skills, and poor motivation. The purpose of this communication is to make a brief characterization of the new elderly population in view of prosthetic and dental management

    Social contacts and loneliness in people with psychotic and mood disorders

    Get PDF
    Background Social relations can be measured through: a) objective indicators, i.e. the number of social contacts in a given time interval or b) subjective indicators, i.e. feelings of loneliness. Comparing subjective and objective indicators in patients with psychotic and mood disorders may help to understand whether diagnosis-specific interventions should be designed for increasing their social relations. In this study we assessed social contacts outside home, work environments and mental health services, which may be increased by these interventions. We also explored feelings of loneliness which could influence readiness of patients to participate in interventions. Methods 100 patients in outpatient mental health care were asked to: a) list their social contacts; b) report their feelings of loneliness on a validated five point Likert scale. Multiple logistic regression models were used to test associations of diagnostic categories with: a) having more than one social contact in the previous week; b) reporting at least moderate feelings of loneliness. Results Patients had on average 1.7 (SD = 1.7) social contacts in the previous week (median = 1.0); 77 patients reported at least moderate feelings of loneliness. Patients with psychotic disorders (n = 30) showed a statistical trend towards having just one or no contacts in the week before the assessment (Odds ratio, OR = 2.246, p =.087). Patients with mood disorders were more likely to report at least moderate feelings of loneliness (OR = 2.798; p <.05). Conclusions Patients with psychotic disorders, compared to those with mood disorders, may be less likely to report feeling lonely although they tend to have less social contacts. Strategies to enhance social relations of people with psychotic disorders may include approaches to increase patients' drive to establish new social contacts and to emotionally support them in this process

    Effects of emphysema on oxygen uptake during maximal exercise in COPD.

    Get PDF

    Familial hypercholesterolemia: The Italian Atherosclerosis Society Network (LIPIGEN)

    Get PDF
    Primary dyslipidemias are a heterogeneous group of disorders characterized by abnormal levels of circulating lipoproteins. Among them, familial hypercholesterolemia is the most common lipid disorder that predisposes for premature cardiovascular disease. We set up an Italian nationwide network aimed at facilitating the clinical and genetic diagnosis of genetic dyslipidemias named LIPIGEN (LIpid TransPort Disorders Italian GEnetic Network)

    Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA)

    Get PDF
    In full-arch implant rehabilitations, when the anterior screw abutment channel compromises the aesthetic of the patient, the OT-Bridge system used with its Seeger rings may provide the necessary retention of the prosthesis. However, no studies have evaluated the forces generated at the Seeger level during loading. This Finite Element Analysis aims to investigate the mechanical behavior of Seeger rings in a mandibular model with four implants and an OT-Bridge system, used without one or two anterior prosthetic screws. A 400 N unilateral load was virtually applied on a 7 mm distal cantilever. Two different variables were considered: the constraint conditions using two or three screws instead of four and the three different framework materials (fiberglass reinforced resin, cobalt-chrome, TiAl6V4). The FEA analysis exhibited tensile and compressive forces on the Seeger closest to the loading point. With the resin framework, a tension force on abutment 3.3 generates a displacement from 5 to 10 times greater than that respectively expressed in metal framework materials. In a full-arch rehabilitation with four implants, the case with three prosthetic screws seems to be a safer and more predictable configuration instead of two. Considering the stress value exhibited and the mechanical properties of the Seeger, the presence of only two prosthetic screws could lead to permanent deformation of the Seeger in the screwless abutment closest to the loading point

    The ETS factor ESE3/EHF represses IL-6 preventing STAT3 activation and expansion of the prostate cancer stem-like compartment.

    Get PDF
    Metastatic prostate cancer represents a yet unsolved clinical problem due to the high frequency of relapse and treatment resistance. Understanding the pathways that lead to prostate cancer progression is an important task to prevent this deadly disease. The ETS transcription factor ESE3/EHF has an important role in differentiation of human prostate epithelial cells. Loss of ESE3/EHF in prostate epithelial cells determines transformation, epithelial-to-mesenchymal transition (EMT) and acquisition of stem-like properties. In this study we identify IL-6 as a direct target of ESE3/EHF that is activated in prostate epithelial cells upon loss of ESE3/EHF. ESE3/EHF and IL-6 were significantly inversely correlated in prostate tumors. Chromatin immunoprecipitation confirmed binding of ESE3/EHF to a novel ETS binding site in the IL-6 gene promoter. Inhibition of IL-6 reverted transformation and stem-like phenotype in tumorigenic ESE3/EHF knockdown prostate epithelial cell models. Conversely, IL-6 stimulation induced malignant phenotypes, stem-like behavior and STAT3 activation. Increased level of IL-6 was observed in prostatospheres compared with adherent bulk cancer cells and this was associated with stronger activation of STAT3. Human prostate tumors with IL-6 elevation and loss of ESE3/EHF were associated with STAT3 activation and displayed upregulation of genes related to cell adhesion, cancer stem-like and metastatic spread. Pharmacological inhibition of IL-6/STAT3 activation by a JAK inhibitor restrained cancer stem cell growth in vitro and inhibited self-renewal in vivo. This study identifies a novel connection between the transcription factor ESE3/EHF and the IL-6/JAK/STAT3 pathway and suggests that targeting this axis might be preferentially beneficial in tumors with loss of ESE3/EHF

    Qualitative evaluation of the effects of professional oral hygiene instruments on prosthetic ceramic surfaces

    Get PDF
    During professional hygiene procedures, different instruments used may cause various damage to dental prostheses. Deplaquing and scaling with curettes and ultrasonic instruments may inadvertently increase the surface roughness of the material and the risk of future bacterial adhesion and/or also compromise the marginal seal of the prosthesis. Hence, the aim of this study was to assess the qualitative effects of two types of curettes and one piezoelectric instrument with a stain-less-steel tip on three types of metal-free samples. After treating the samples with different instru-mentations, they were analyzed using the scanning electron microscope and then underwent a qualitative microanalysis by using a spectroscopy machine. All the materials tested in this study have undergone significant changes of their superficial structure after instrumentation both with mechanical and manual instruments. Plastic curettes appeared to be less aggressive than the other in-struments. Disilicate samples show a significantly lower degree of surface glazing erosion com-pared to the zirconia sample with all the instruments used

    Comparative analysis of the stability of prosthetic screws under cyclic loading in implant prosthodontics: An in vitro study

    Get PDF
    Background: To compare the loss of preload in absence of loading and after a fixed number of cyclic loadings on 7-mm distal cantilever in two different connection systems using all-on-four prosthetic model. Methods: Two equal models of an edentulous mandible rehabilitated with all-on-four technique with two types of abutment system (MUA and OT-Bridge) supporting a hybrid prosthesis, were used. Initial torque values of the prosthetic fixing screw, after ten minutes from initial screw tightening and after 400,000 repeated loadings were registered using a mechanical torque gauge. Differences between initial and final torque values were reported for each anchoring system and the two systems were finally compared. Results: No statistically significant differences regarding the loss of preload between MUA and OT-Bridge system were found after 400,000 cyclic loadings; however, in MUA system it was found between anterior and posterior implant screws. A significant difference in preload loss was found only for MUA system comparing the initial screw torque to that measured after 10 min from the tightening in absence of cyclic loadings. Conclusions: Within the limits of the present study, MUA and OT-Bridge may be considered reliable prosthetic anchoring systems able to tolerate repeated cyclic occlusal loads on distal cantilever in all-on-four rehabilitation model without any significant loss of preload in screw tightening
    corecore