220 research outputs found
The impact of wastewater treatment effluent on Crocodile River quality in Ehlanzeni District, Mpumalanga Province, South Africa
Excessive discharge of poorly treated effluent has impacted global water resource systems intensely. The declining state of wastewater treatment plants (WWTPs) is a significant source of pollution in water resources. There is evidence of water resource quality deterioration in natural environments caused by effluent discharges. We assessed the impact of wastewater treatment effluent on the quality of the Crocodile River. For spatial distribution, we collected data from three WWTPs discharging effluent into the Crocodile River and from three points situated downstream of each WWTP. Physicochemical and microbiological parameters such as pH, electrical conductivity, chemical oxygen demand, phosphates, nitrates, ammonia, and Escherichia coli were analysed using standard methods of the American Public Health Association. The water quality index was also calculated to give an overall indication of pollution within the catchment. The results show that WWTPs were not complying with the effluent standards set out in their water use licence. The WWTP effluent had a negative impact on downstream water quality, with the water quality index indicating low quality of discharged effluent. It is recommended that a regular and consistent water resource quality monitoring programme be implemented, particularly in areas where effluent discharges are prevalent.
Significance:In many African nations, water pollution is a serious problem that may be traced to a variety of sources. Surface water pollution has adverse effects on aquatic ecosystems and reduces the availability of clean water. In most semi-arid to dry southern African regions (e.g. South Africa), water scarcity is a significant concern. In these regions, water is a vital resource that must be protected at all times, given that the inadequate infrastructure of wastewater treatment facilities adds to the decline in South Africa’s water quality standard
Preparation of Knill-Laflamme-Milburn states using tunable controlled phase gate
A specific class of partially entangled states known as
Knill-Laflamme-Milburn states (or KLM states) has been proved to be useful in
relation to quantum information processing [Knill et al., Nature 409, 46
(2001)]. Although the usage of such states is widely investigated, considerably
less effort has been invested into experimentally accessible preparation
schemes. This paper discusses the possibility to employ a tunable controlled
phase gate to generate an arbitrary Knill-Laflamme-Milburn state. In the first
part, the idea of using the controlled phase gate is explained on the case of
two-qubit KLM states. Optimization of the proposed scheme is then discussed for
the framework of linear optics. Subsequent generalization of the scheme to
arbitrary n-qubit KLM state is derived in the second part of this paper.Comment: 5 pages, 4 figures, accepted in Journal of Physics
Multiplexed gas spectroscopy using tunable VCSELs
Detection and identification of gas species using tunable laser diode laser absorption spectroscopy has been performed using vertical cavity surface emitting lasers (VCSEL). Two detection methods are compared: direct absorbance and wavelength modulation spectroscopy (WMS). In the first, the output of a DC-based laser is directly monitored to detect for any quench at the targeted specie wavelength. In the latter, the emission wavelength of the laser is modulated by applying a sinusoidal component on the drive current of frequency {omega}, and measuring the harmonics component (2{omega}) of the photo-detected current. This method shows a better sensitivity measured as signal to noise ratio, and is less susceptible to interference effects such as scattering or fouling. Gas detection was initially performed at room temperature and atmospheric conditions using VCSELs of emission wavelength 763 nm for oxygen and 1392 nm for water, scanning over a range of approximately 10 nm, sufficient to cover 5-10 gas specific absorption lines that enable identification and quantization of gas composition. The amplitude and frequency modulation parameters were optimized for each detected gas species, by performing two dimensional sweeps for both tuning current and either amplitude or frequency, respectively. We found that the highest detected signal is observed for a wavelength modulation amplitude equal to the width of the gas absorbance lines, in good agreement with theoretical calculations, and for modulation frequencies below the time response of the lasers (<50KHz). In conclusion, we will discuss limit of detection studies and further implementation and packaging of VCSELs in diode arrays for continuous and simultaneous monitoring of multiple species in gaseous mixtures
Mesoscopic superpositions of vibronic collective states of N trapped ions
We propose a scalable procedure to generate entangled superpositions of
motional coherent states and electronic states in N trapped ions. Beyond their
fundamental importance, these states may be of interest for quantum information
processing and may be used in experimental studies of decoherence.Comment: Final version, as published in Physical Review Letters. See also
further developments and applications in quant-ph/020207
Inductively Heated Shape Memory Polymer for the Magnetic Actuation of Medical Devices
Submitted to IEEE Trans. Biomed. Eng.Presently there is interest in making medical devices such as expandable stents and intravascular microactuators from shape memory polymer (SMP). One of the key challenges in realizing SMP medical devices is the implementation of a safe and effective method of thermally actuating various device geometries in vivo. A novel scheme of actuation by Curie-thermoregulated inductive heating is presented. Prototype medical devices made from SMP loaded with Nickel Zinc ferrite ferromagnetic particles were actuated in air by applying an alternating magnetic field to induce heating. Dynamic mechanical thermal analysis was performed on both the particle-loaded and neat SMP materials to assess the impact of the ferrite particles on the mechanical properties of the samples. Calorimetry was used to quantify the rate of heat generation as a function of particle size and volumetric loading of ferrite particles in the SMP. These tests demonstrated the feasibility of SMP actuation by inductive heating. Rapid and uniform heating was achieved in complex device geometries and particle loading up to 10% volume content did not interfere with the shape recovery of the SMP.Lawrence Livermore National Lab
Coherent state quantization of a particle in de Sitter space
We present a coherent state quantization of the dynamics of a relativistic
test particle on a one-sheet hyperboloid embedded in a three-dimensional
Minkowski space. The group SO_0(1,2) is considered to be the symmetry group of
the system. Our procedure relies on the choice of coherent states of the motion
on a circle. The coherent state realization of the principal series
representation of SO_0(1,2) seems to be a new result.Comment: Journal of Physics A: Mathematical and General, vol. 37, in pres
Recommended from our members
A Shape Memory Polymer Dialysis Needle Adapter for the Reduction of Hemodynamic Stress within Arteriovenous Grafts
A deployable, shape memory polymer adapter is investigated for reducing the hemodynamic stress caused by a dialysis needle flow within an arteriovenous graft. Computational fluid dynamics simulations of dialysis sessions with and without the adapter demonstrate that the adapter provides a significant decrease in the wall shear stress. In vitro flow visualization measurements are made within a graft model following delivery and actuation of a prototype shape memory polymer adapter. Vascular access complications resulting from arteriovenous (AV) graft failures account for over $1 billion per year in the health care costs of dialysis patients in the U.S.[1] The primary mode of failure of arteriovenous fistulas (AVF's) and polytetrafluoroethylene (PTFE) grafts is the development of intimal hyperplasia (IH) and the subsequent formation of stenotic lesions, resulting in a graft flow decline. The hemodynamic stresses arising within AVF's and PTFE grafts play an important role in the pathogenesis of IH. Studies have shown that vascular damage can occur in regions where there is flow separation, oscillation, or extreme values of wall shear stress (WSS).[2] Nevaril et al.[3] show that exposure of red blood cells to WSS's on the order of 1500 dynes/cm2 can result in hemolysis. Hemodynamic stress from dialysis needle flow has recently been investigated for the role it plays in graft failure. Using laser Doppler velocimetry measurements, Unnikrishnan et al.[4] show that turbulence intensities are 5-6 times greater in the AV flow when the needle flow is present and that increased levels of turbulence exist for approximately 7-8cm downstream of the needle. Since the AVF or PTFE graft is exposed to these high levels of hemodynamic stress several hours each week during dialysis sessions, it is quite possible that needle flow is an important contributor to vascular access occlusion.[4] We present a method for reducing the hemodynamic stress in an AV graft by tailoring the fluid dynamics of the dialysis needle flow using a deployable shape memory polymer (SMP) dialysis needle adapter. Such an adapter is deployed through the needle into the graft where it is actuated into an expanded shape using thermal energy. The expanded adapter has a tube-like shape, in which the distal end has a larger cross-sectional area than that of the needle. When the dialysis session is completed, the adapter is retracted through the needle. In this initial study, we conduct computational fluid dynamics (CFD) simulations to assess the changes in the hemodynamic stress on a graft wall when the SMP adapter is utilized. Additionally, we fabricate a prototype SMP adapter and deploy it in an in vitro model of an AV graft
Recommended from our members
Shape Memory Polymer Therapeutic Devices for Stroke
Shape memory polymers (SMPs) are attracting a great deal of interest in the scientific community for their use in applications ranging from light weight structures in space to micro-actuators in MEMS devices. These relatively new materials can be formed into a primary shape, reformed into a stable secondary shape, and then controllably actuated to recover their primary shape. The first part of this presentation will be a brief review of the types of polymeric structures which give rise to shape memory behavior in the context of new shape memory polymers with highly regular network structures recently developed at LLNL for biomedical devices. These new urethane SMPs have improved optical and physical properties relative to commercial SMPs, including improved clarity, high actuation force, and sharper actuation transition. In the second part of the presentation we discuss the development of SMP based devices for mechanically removing neurovascular occlusions which result in ischemic stroke. These devices are delivered to the site of the occlusion in compressed form, are pushed through the occlusion, actuated (usually optically) to take on an expanded conformation, and then used to dislodge and grip the thrombus while it is withdrawn through the catheter
Development of an automated DNA purification module using a micro-fabricated pillar chip
We present a fully automated DNA purification module comprised of a micro-fabricated chip and sequential injection analysis system that is designed for use within autonomous instruments that continuously monitor the environment for the presence of biological threat agents. The chip has an elliptical flow channel containing a bed (3.5 × 3.5 mm) of silica-coated pillars with height, width and center-to-center spacing of 200, 15, and 30 µm, respectively, which provides a relatively large surface area (ca. 3 cm2) for DNA capture in the presence of chaotropic agents. We have characterized the effect of various fluidic parameters on extraction performance, including sample input volume, capture flow rate, and elution volume. The flow-through design made the pillar chip completely reusable; carryover was eliminated by flushing lines with sodium hypochlorite and deionized water between assays. A mass balance was conducted to determine the fate of input DNA not recovered in the eluent. The device was capable of purifying and recovering Bacillus anthracis genomic DNA (input masses from 0.32 to 320 pg) from spiked environmental aerosol samples, for subsequent analysis using polymerase chain reaction-based assays.<br /
Spin Transport in a Quantum Wire
We study the effect of electron-electron backscattering interactions on spin
transport in a quantum wire. Even if these interactions have no significant
effect on charge transport, they strongly influence the transport of spin. We
use the quantum Boltzmann equation in the collision approximation to derive
equations of motion for spin current and magnetization. In the limit of small
perturbations from equilibrium, we explain the existence of `precessional' and
`diffusive' behaviors. We also discuss the low-temperature non-linear decay of
an uniform spin current outside the hydrodynamic regime.Comment: 10 pages, 5 figures, REVTE
- …