2,615 research outputs found
Improved Fast Neutron Spectroscopy via Detector Segmentation
Organic scintillators are widely used for fast neutron detection and
spectroscopy. Several effects complicate the interpretation of results from
detectors based upon these materials. First, fast neutrons will often leave a
detector before depositing all of their energy within it. Second, fast neutrons
will typically scatter several times within a detector, and there is a
non-proportional relationship between the energy of, and the scintillation
light produced by, each individual scatter; therefore, there is not a
deterministic relationship between the scintillation light observed and the
neutron energy deposited. Here we demonstrate a hardware technique for reducing
both of these effects. Use of a segmented detector allows for the
event-by-event correction of the light yield non-proportionality and for the
preferential selection of events with near-complete energy deposition, since
these will typically have high segment multiplicities.Comment: Accepted for publication in Nuclear Instruments and Methods in
Physics Research Section
Simulations of Galactic Cosmic Rays Impacts on the Herschel/PACS Photoconductor Arrays with Geant4 Code
We present results of simulations performed with the Geant4 software code of
the effects of Galactic Cosmic Ray impacts on the photoconductor arrays of the
PACS instrument. This instrument is part of the ESA-Herschel payload, which
will be launched in late 2007 and will operate at the Lagrangian L2 point of
the Sun-Earth system. Both the Satellite plus the cryostat (the shield) and the
detector act as source of secondary events, affecting the detector performance.
Secondary event rates originated within the detector and from the shield are of
comparable intensity. The impacts deposit energy on each photoconductor pixel
but do not affect the behaviour of nearby pixels. These latter are hit with a
probability always lower than 7%. The energy deposited produces a spike which
can be hundreds times larger than the noise. We then compare our simulations
with proton irradiation tests carried out for one of the detector modules and
follow the detector behaviour under 'real' conditions.Comment: paper submitted to Experimental Astronomy in March 200
A mobile antineutrino detector with plastic scintillators
We propose a new type segmented antineutrino detector made of plastic
scintillators for the nuclear safeguard application. A small prototype was
built and tested to measure background events. A satisfactory unmanned field
operation of the detector system was demonstrated. Besides, a detailed Monte
Carlo simulation code was developed to estimate the antineutrino detection
efficiency of the detector.Comment: 23 pages, 11 figures; accepted for publication in Nuclear Instruments
and Methods in Physics Research
A new design for the CERN-Fr\'ejus neutrino Super Beam
We present an optimization of the hadron focusing system for a low-energy
high-intensity conventional neutrino beam (Super-Beam) proposed on the basis of
the HP-SPL at CERN with a beam power of 4 MW and an energy of 4.5 GeV. The far
detector would be a 440 kton Water Cherenkov detector (MEMPHYS) located at a
baseline of 130 km in the Fr\'ejus site. The neutrino fluxes simulation relies
on a new GEANT4 based simulation coupled with an optimization algorithm based
on the maximization of the sensitivity limit on the mixing angle.
A new configuration adopting a multiple horn system with solid targets is
proposed which improves the sensitivity to and the CP violating
phase .Comment: 11 pages, 18 figures, 2 table
A practical algorithmic approach to mature aggressive B cell lymphoma diagnosis in the double/triple hit era. Selecting cases, matching clinical benefit. A position paper from the Italian Group of Haematopathology (G.I.E.)
An accurate diagnosis of clinically distinct subgroups of aggressive mature B cell lymphomas is crucial for the choice of proper treatment. Presently, precise recognition of these disorders relies on the combination of morphological, immunophenotypical, and cytogenetic/molecular features. The diagnostic workup in such situations implies the application of costly and time-consuming analyses, which are not always required, since an intensified treatment option is reasonably reserved to fit patients. The Italian Group of Haematopathology proposes herein a practical algorithm for the diagnosis of aggressive mature B cell lymphomas based on a stepwise approach, aimed to select cases deserving molecular analysis, in order to optimize time and resources still assuring the optimal management for any patient
The politics of alcohol policy in Nigeria: a critical analysis of how and why brewers use strategic ambiguity to supplant policy initiatives
The global call by the World Health Assembly (WHA) to control the rising alcohol-related problems caused by harmful consumption through policy became necessary in 2005 due to the recognition of the fact that many countries did not have alcohol policies. This gave rise to the adoption of a ten-point policy strategy by the World Health Organization (WHO) Member States in 2010. Against this backdrop, many countries adopted alcohol policies to reduce harmful alcohol consumption. Nigeria was one of the WHO Member Countries that adopted the resolution. Nigeria is among the 30 countries with the highest per capita consumption and alcohol-related problems, yet has not formulated alcohol policy to date. This paper draws on Eisenberg’s Strategic Ambiguity Model to explore the role of brewers in supplanting alcohol policy initiatives in Nigeria. It argues that the leading alcohol producers in Nigeria have been the main reason alcohol policies have not been formulated. The article focuses on why their campaigns for responsible drinking, promotions, sponsorships and ‘strategic social responsibilities’ may have increased since the WHA made the call and the WHO adopted the resolution in 2010. It concludes by arguing that there is an urgent need to formulate policies drawing from the WHO resolution to curtail the activities of these brewers and reduce harmful consumption
The application of Geant4 simulation code for brachytherapy treatment
Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models
Scintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV
The scintillation efficiency of liquid xenon for nuclear recoils has been
measured to be nearly constant in the recoil energy range from 140 keV down to
5 keV. The average ratio of the efficiency for recoils to that for gamma-rays
is found to be 0.19+-0.02.Comment: 13 pages, 5 figure
Simulation of Light Antinucleus-Nucleus Interactions
Creations of light anti-nuclei (anti-deuterium, anti-tritium, anti-He3 and
anti-He4) are observed by collaborations at the LHC and RHIC accelerators. Some
cosmic ray experiments are aimed to find the anti-nuclei in cosmic rays. To
support the experimental studies of the anti-nuclei a Monte Carlo simulation of
anti-nuclei interactions with matter is implemented in the Geant4 toolkit. The
implementation combines practically all known theoretical approaches to the
problem of antinucleon-nucleon interactions.Comment: 8 pages, 5 figure
Electron-hadron shower discrimination in a liquid argon time projection chamber
By exploiting structural differences between electromagnetic and hadronic showers in a multivariate analysis we present an efficient Electron-Hadron discrimination algorithm for liquid argon time projection chambers, validated using Geant4 simulated data
- …
