416 research outputs found

    Sampling and measurement methods for a study of childhood refractive error in a UK population

    Get PDF
    International audienceBackground There is a paucity of data describing the prevalence of childhood refractive error in the United Kingdom. The Northern Ireland Childhood Errors of Refraction study, along with its sister study the Aston Eye Study, are the first population-based surveys of children using both random cluster sampling and cycloplegic autorefraction to quantify levels of refractive error in the United Kingdom. Methods Children aged 6-7 years and 12-13 years were recruited from a stratified random sample of primary and post-primary schools, representative of the population of Northern Ireland as a whole. Measurements included assessment of visual acuity, oculomotor balance, ocular biometry and cycloplegic binocular open-field autorefraction. Questionnaires were used to identify putative risk factors for refractive error. Results 399 (57%) of 6-7 years and 669 (60%) of 12-13 years participated. School participation rates did not vary statistically significantly with the size of the school, whether the school is urban or rural, or whether it is in a deprived/non-deprived area. The gender balance, ethnicity and type of schooling of participants are reflective of the Northern Ireland population. Conclusions The study design, sample size and methodology will ensure accurate measures of the prevalence of refractive errors in the target population and will facilitate comparisons with other population-based refractive data

    Overexpression and knock-down studies highlight that a disintegrin and metalloproteinase 28 controls proliferation and migration in human prostate cancer

    Get PDF
    Prostate cancer is one of the most prevalent cancers inmen. It is critical to identify and characterize oncogenes that drive the pathogenesis of human prostate cancer. The current study builds upon previous research showing that a disintegrin and metalloproteinase (ADAM)28 is involved in the pathogenesis of numerous cancers. Our novel study used overexpression, pharmacological, and molecular approaches to investigate the biological function of ADAM28 in human prostate cancer cells,with a focus on cell proliferation andmigration. The results of this study provide important insights into the role of metalloproteinases in human prostate cancer. The expression of ADAM28 protein levels was assessed within human prostate tumors and normal adjacent tissue by immunohistochemistry. Immunocytochemistry and western blotting were used to assess ADAM28 protein expression in human prostate cancer cell lines. Functional assays were conducted to assess proliferation and migration in human prostate cancer cells in which ADAM28 protein expression or activity had been altered by overexpression, pharmacological inhibition, or by siRNA gene knockdown. The membrane bound ADAM28 was increased in human tumor biopsies and prostate cancer cell lines. Pharmacological inhibition of ADAM28 activity and/or knockdown of ADAM28 significantly reduced proliferation and migration of human prostate cancer cells, while overexpression of ADAM28 significantly increased proliferation and migration. ADAM28 is overexpressed in primary human prostate tumor biopsies, and it promotes human prostate cancer cell proliferation and migration. This study supports the notion that inhibition of ADAM28 may be a potential novel therapeutic strategy for human prostate cancer. Abbreviations: ADAM = a disintegrin and metalloproteinase, CTGF = connective tissue growth factor, DHT = dihydrotestosterone, IGF = insulin-like growth factor, IGFBP-3 = IGF binding protein-3, IL-6 = interleukin 6, RPMI = Roswell Park Memorial Institute, VEGF = vascular endothelial growth factor, VWF = von Willebrand factor

    First-trimester or second-trimester screening, or both, for Down's syndrome

    Get PDF
    BACKGROUND: It is uncertain how best to screen pregnant women for the presence of fetal Down's syndrome: to perform first-trimester screening, to perform second-trimester screening, or to use strategies incorporating measurements in both trimesters.METHODS: Women with singleton pregnancies underwent first-trimester combined screening (measurement of nuchal translucency, pregnancy-associated plasma protein A [PAPP-A], and the free beta subunit of human chorionic gonadotropin at 10 weeks 3 days through 13 weeks 6 days of gestation) and second-trimester quadruple screening (measurement of alpha-fetoprotein, total human chorionic gonadotropin, unconjugated estriol, and inhibin A at 15 through 18 weeks of gestation). We compared the results of stepwise sequential screening (risk results provided after each test), fully integrated screening (single risk result provided), and serum integrated screening (identical to fully integrated screening, but without nuchal translucency).RESULTS: First-trimester screening was performed in 38,167 patients; 117 had a fetus with Down's syndrome. At a 5 percent false positive rate, the rates of detection of Down's syndrome were as follows: with first-trimester combined screening, 87 percent, 85 percent, and 82 percent for measurements performed at 11, 12, and 13 weeks, respectively; with second-trimester quadruple screening, 81 percent; with stepwise sequential screening, 95 percent; with serum integrated screening, 88 percent; and with fully integrated screening with first-trimester measurements performed at 11 weeks, 96 percent. Paired comparisons found significant differences between the tests, except for the comparison between serum integrated screening and combined screening.CONCLUSIONS: First-trimester combined screening at 11 weeks of gestation is better than second-trimester quadruple screening but at 13 weeks has results similar to second-trimester quadruple screening. Both stepwise sequential screening and fully integrated screening have high rates of detection of Down's syndrome, with low false positive rates

    Prospective evaluation of an artificial intelligence-enabled algorithm for automated diabetic retinopathy screening of 30 000 patients.

    Get PDF
    BACKGROUND/AIMS: Human grading of digital images from diabetic retinopathy (DR) screening programmes represents a significant challenge, due to the increasing prevalence of diabetes. We evaluate the performance of an automated artificial intelligence (AI) algorithm to triage retinal images from the English Diabetic Eye Screening Programme (DESP) into test-positive/technical failure versus test-negative, using human grading following a standard national protocol as the reference standard. METHODS: Retinal images from 30 405 consecutive screening episodes from three English DESPs were manually graded following a standard national protocol and by an automated process with machine learning enabled software, EyeArt v2.1. Screening performance (sensitivity, specificity) and diagnostic accuracy (95% CIs) were determined using human grades as the reference standard. RESULTS: Sensitivity (95% CIs) of EyeArt was 95.7% (94.8% to 96.5%) for referable retinopathy (human graded ungradable, referable maculopathy, moderate-to-severe non-proliferative or proliferative). This comprises sensitivities of 98.3% (97.3% to 98.9%) for mild-to-moderate non-proliferative retinopathy with referable maculopathy, 100% (98.7%,100%) for moderate-to-severe non-proliferative retinopathy and 100% (97.9%,100%) for proliferative disease. EyeArt agreed with the human grade of no retinopathy (specificity) in 68% (67% to 69%), with a specificity of 54.0% (53.4% to 54.5%) when combined with non-referable retinopathy. CONCLUSION: The algorithm demonstrated safe levels of sensitivity for high-risk retinopathy in a real-world screening service, with specificity that could halve the workload for human graders. AI machine learning and deep learning algorithms such as this can provide clinically equivalent, rapid detection of retinopathy, particularly in settings where a trained workforce is unavailable or where large-scale and rapid results are needed

    Genetic characterization of early renal changes in a novel mouse model of diabetic kidney disease

    Get PDF
    Genetic factors influence susceptibility to diabetic kidney disease. Here we mapped genes mediating renal hypertrophic changes in response to diabetes. A survey of 15 mouse strains identified variation in diabetic kidney hypertrophy. Strains with greater (FVB/N(FVB)) and lesser (C57BL/6 (B6)) responses were crossed and diabetic F2 progeny were characterized. Kidney weights of diabetic F2 mice were broadly distributed. Quantitative trait locus analyses revealed diabetic mice with kidney weights in the upper quartile shared alleles on chromosomes (chr) 6 and 12; these loci were designated as Diabetic kidney hypertrophy (Dkh)-1 and -2. To confirm these loci, reciprocal congenic mice were generated with defined FVB chromosome segments on the B6 strain background (B6.Dkh1/2f) or vice versa (FVB.Dkh1/2b). Diabetic mice of the B6.Dkh1/2f congenic strain developed diabetic kidney hypertrophy, while the reciprocal FVB.Dkh1/2b congenic strain was protected. The chr6 locus contained the candidate gene; Ark1b3, coding aldose reductase; the FVB allele has a missense mutation in this gene. Microarray analysis identified differentially expressed genes between diabetic B6 and FVB mice. Thus, since the two loci identified by quantitative trait locus mapping are syntenic with regions identified for human diabetic kidney disease, the congenic strains we describe provide a valuable new resource to study diabetic kidney disease and test agents that may prevent it

    Visual Acuity Measures Do Not Reliably Detect Childhood Refractive Error - an Epidemiological Study

    Get PDF
    PURPOSE: To investigate the utility of uncorrected visual acuity measures in screening for refractive error in white school children aged 6-7-years and 12-13-years. METHODS: The Northern Ireland Childhood Errors of Refraction (NICER) study used a stratified random cluster design to recruit children from schools in Northern Ireland. Detailed eye examinations included assessment of logMAR visual acuity and cycloplegic autorefraction. Spherical equivalent refractive data from the right eye were used to classify significant refractive error as myopia of at least 1DS, hyperopia as greater than +3.50DS and astigmatism as greater than 1.50DC, whether it occurred in isolation or in association with myopia or hyperopia. RESULTS: Results are presented from 661 white 12-13-year-old and 392 white 6-7-year-old school-children. Using a cut-off of uncorrected visual acuity poorer than 0.20 logMAR to detect significant refractive error gave a sensitivity of 50% and specificity of 92% in 6-7-year-olds and 73% and 93% respectively in 12-13-year-olds. In 12-13-year-old children a cut-off of poorer than 0.20 logMAR had a sensitivity of 92% and a specificity of 91% in detecting myopia and a sensitivity of 41% and a specificity of 84% in detecting hyperopia. CONCLUSIONS: Vision screening using logMAR acuity can reliably detect myopia, but not hyperopia or astigmatism in school-age children. Providers of vision screening programs should be cognisant that where detection of uncorrected hyperopic and/or astigmatic refractive error is an aspiration, current UK protocols will not effectively deliver

    En rapport om politisk filosofi og sundhed

    Get PDF
    This report takes the matter of a state’s intervention towards its individuals into dis-cussion from the perspective of social health care, and the recent changes in law, concerning smoking, and taxes on fat. The government in Denmark has been accused of being paternalistic and of interacting too much in the citizen’s personal life. By including John Stuart Mill, recent investigations, the public discussion and a list of modern ethical magazine articles, we set up a discussion about, under which pre-mises, and why a state should be allowed to adjust the behaviour of its citizens. The answer to this question is not clear, at it fairly early in the process became clear that the arguments is based, not only on a matter of principal opinion, but also on, in which way the agitator views upon freedom. We, as I. Berlin, divide freedom into two categories: Positive and negative freedom. The project concludes that if arguing from a point of view that understands freedom in the positive (or total) sense, it is not possible to create valid arguments for interfering with an individual’s behaviour, as long as it does not affect the life of other individuals. However, understanding free-dom in the positive way will make it possible to interject, when people are living an unhealthy life. The report also concludes that living in a modern democracy, with an understanding of the freedom as an unbendable (and positive) size, is impossible

    The New Normals of Work: a framework for understanding responses to disruptions created by new futures of work

    Get PDF
    The COVID-19 pandemic led to governments advising citizens to engage in ’social distancing’ measures. These measures included working from home rather than in an office. As a result, many people had to rapidly develop new working strategies. As we look to a new future of work, with many workplaces examining long-term remote or hybrid working set-ups, it is important to understand how people developed remote working strategies and the contextual factors that precluded workers from maximising the potential of technology. Using a two-stage approach including a qualitative survey and a series of in-depth interviews, we investigated the challenges people experienced in creating effective workspaces, getting work done and connecting with others that surfaced during the COVID-19 crisis. We adapt a framework used in healthcare to the work context to make sense of how people cope with this disruption to find a new normal. From this, we identify instances of how people adapt to the new normal, where they avoid adaption and where they anticipate future changes. This gives us an understanding of how people adapt to the changing nature of work in response to the pandemic and offers a lens that may help to understand other future disruptions to work
    • …
    corecore