309 research outputs found

    Phase vortices from a Young's three-pinhole interferometer

    Full text link
    An analysis is presented of the phase vortices generated in the far field, by an arbitrary arrangement of three monochromatic point sources of complex spherical waves. In contrast with the case of three interfering plane waves, in which an infinitely-extended vortex lattice is generated, the spherical sources generate a finite number of phase vortices. Analytical expressions for the vortex core locations are developed and shown to have a convenient representation in a discrete parameter space. Our analysis may be mapped onto the case of a coherently-illuminated Young's interferometer, in which the screen is punctured by three rather than two pinholes.Comment: 10 pages, 8 figures, REVTeX4, Submitted to Phys. Rev.

    Utilizing computed tomography volumetry for size matching prior to lung transplantation: A case series

    Get PDF
    BACKGROUND: Appropriate size matching between donor and recipient is critical for successful pulmonary transplantation. Although surrogate measurements such as height and gender are often utilized to approximate predicted lung volume, these methods provide only a gross estimation with wide variability and poor predictive value. CASE DESCRIPTION: A single center exploratory study was conducted in which four patients underwent lung transplantation (LT) with pre-operative computed tomography (CT) volumetry obtained in both the donor and recipient to facilitate decision making regarding organ size and suitability. In four cases in which CT volumetry was used, the lung volumes calculated using surrogate measurements significantly overestimated both donor and recipient lung volumes quantified by CT volumetric analysis. All recipients underwent successful LT without necessary graft downsizing. CONCLUSIONS: This is an initial report of prospectively utilizing CT volumetry as an adjunct to decision-making regarding suitability of donor lungs. In these cases, CT volumetry facilitated the confident acceptance of donor lungs that were initially predicted to be oversized based on other clinical measures

    Economic evaluation of the specialized donor care facility for thoracic organ donor management

    Get PDF
    Background: Over the last decade two alternative models of donor care have emerged in the United States: the conventional model, whereby donors are managed at the hospital where brain death occurs, and the specialized donor care facility (SDCF), in which brain dead donors are transferred to a SDCF for medical optimization and organ procurement. Despite increasing use of the SDCF model, its cost-effectiveness in comparison to the conventional model remains unknown. Methods: We performed an economic evaluation of the SDCF and conventional model of donor care from the perspective of U.S. transplant centers over a 2-year study period. In this analysis, we utilized nationwide data from the Scientific Registry of Transplant Recipients and controlled for donor characteristics and patterns of organ sharing across the nation\u27s organ procurement organizations (OPOs). Subgroup analysis was performed to determine the impact of the SDCF model on thoracic organ transplants. Results: A total of 38,944 organ transplants were performed in the U.S. during the study period from 13,539 donors with an observed total organ cost of 1.36billion.IfeveryOPOassumedthecostandeffectivenessoftheSDCFmodel,apredicted39,155organtransplants(+211)wouldhavebeenperformedwithapredictedtotalorgancostof1.36 billion. If every OPO assumed the cost and effectiveness of the SDCF model, a predicted 39,155 organ transplants (+211) would have been performed with a predicted total organ cost of 1.26 billion (-100million).SubgroupanalysisofthoracicorgansrevealedthattheSDCFmodelwouldleadtoapredicted156additionaltransplantswithacostsavingof100 million). Subgroup analysis of thoracic organs revealed that the SDCF model would lead to a predicted 156 additional transplants with a cost saving of 24.6 million. Conclusions: The U.S. SDCF model may be a less costly and more effective means of multi-organ donor management, particularly for thoracic organ donors, compared to the conventional hospital-based model

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 6060^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law EγE^{-\gamma} with index γ=2.70±0.02(stat)±0.1(sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25(stat)1.2+1.0(sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    Adsorption of hydroxamate siderophores and EDTA on goethite in the presence of the surfactant sodium dodecyl sulfate

    Get PDF
    Siderophore-promoted iron acquisition by microorganisms usually occurs in the presence of other organic molecules, including biosurfactants. We have investigated the influence of the anionic surfactant sodium dodecyl sulfate (SDS) on the adsorption of the siderophores DFOB (cationic) and DFOD (neutral) and the ligand EDTA (anionic) onto goethite (α-FeOOH) at pH 6. We also studied the adsorption of the corresponding 1:1 Fe(III)-ligand complexes, which are products of the dissolution process. Adsorption of the two free siderophores increased in a similar fashion with increasing SDS concentration, despite their difference in molecule charge. In contrast, SDS had little effect on the adsorption of EDTA. Adsorption of the Fe-DFOB and Fe-DFOD complexes also increased with increasing SDS concentrations, while adsorption of Fe-EDTA decreased. Our results suggest that hydrophobic interactions between adsorbed surfactants and siderophores are more important than electrostatic interactions. However, for strongly hydrophilic molecules, such as EDTA and its iron complex, the influence of SDS on their adsorption seems to depend on their tendency to form inner-sphere or outer-sphere surface complexes. Our results demonstrate that surfactants have a strong influence on the adsorption of siderophores to Fe oxides, which has important implications for siderophore-promoted dissolution of iron oxides and biological iron acquisition

    Increasing Respiratory Effort With 100% Oxygen During Resuscitation of Preterm Rabbits at Birth

    Get PDF
    Background: Spontaneous breathing is essential for successful non-invasive respiratory support delivered by a facemask at birth. As hypoxia is a potent inhibitor of spontaneous breathing, initiating respiratory support with a high fraction of inspired O2 may reduce the risk of hypoxia and increase respiratory effort at birth. Methods: Preterm rabbit kittens (29 days gestation, term ~32 days) were delivered and randomized to receive continuous positive airway pressure with either 21% (n = 12) or 100% O2 (n = 8) via a facemask. If apnea occurred, intermittent positive pressure ventilation (iPPV) was applied with either 21% or 100% O2 in kittens who started in 21% O2, and remained at 100% O2 for kittens who started the experiment in 100% O2. Respiratory rate (breaths per minute, bpm) and variability in inter-breath interval (%) were measured from esophageal pressure recordings and functional residual capacity (FRC) was measured from synchrotron phase-contrast X-ray images. Results: Initially, kittens receiving 21% O2 had a significantly lower respiratory rate and higher variability in inter-breath interval, indicating a less stable breathing pattern than kittens starting in 100% O2 [median (IQR) respiratory rate: 16 (4–28) vs. 38 (29–46) bpm, p = 0.001; variability in inter-breath interval: 33.3% (17.2–50.1%) vs. 27.5% (18.6–36.3%), p = 0.009]. Apnea that required iPPV, was more frequently observed in kittens in whom resuscitation was started with 21% compared to 100% O2 (11/12 vs. 1/8, p = 0.001). After recovering from apnea, respiratory rate was significantly lower and variability in inter-breath interval was significantly higher in kittens who received iPPV with 21% compared to 100% O2. FRC was not different between study groups at both timepoints. Conclusion: Initiating resuscitation with 100% O2 resulted in increased respiratory activity and stability, thereby reducing the risk of apnea and need for iPPV after birth. Further studies in human preterm infants are mandatory to confirm the benefit of this approach in terms of oxygenation. In addition, the ability to avoid hyperoxia after initiation of resuscitation with 100% oxygen, using a titration protocol based on oxygen saturation, needs to be clarified
    corecore