724 research outputs found

    Precision Electroweak Measurements at the SLC : Overview and Perspective

    Get PDF
    Preliminary SLD electroweak results based on essentially the complete 550K Z dataset are presented and interpreted, and some historical background is provided.Comment: 5 pages, 2 figures, from "Weak Interactions and Neutrinos, 1999", Feb. 199

    Experimental Issues for Precision Electroweak Physics at a High-Luminosity Z Factory

    Get PDF
    We discuss the ultimate precision for ALR, and therefore for the weak mixing angle, at a high-luminosity Linear Collider. Drawing on our experience at the SLC, and considering various machine parameter sets for the NLC and for TESLA, it emerges that a compromise between peak luminosity and precision will be a likely outcome. This arises due to the severe requirements on the uncertainty in the luminosity weighted collision energy (Ecm). We consider the cases with and without a polarized positron beam.Comment: Submitted to LCWS2000 (Linear Collider Workshop 20000), Fermilab, 10-24-200

    Highlights of the SLD Physics Program at the SLAC Linear Collider

    Get PDF
    Starting in 1989, and continuing through the 1990s, high-energy physics witnessed a flowering of precision measurements in general and tests of the standard model in particular, led by e+e- collider experiments operating at the Z0 resonance. Key contributions to this work came from the SLD collaboration at the SLAC Linear Collider. By exploiting the unique capabilities of this pioneering accelerator and the SLD detector, including a polarized electron beam, exceptionally small beam dimensions, and a CCD pixel vertex detector, SLD produced a broad array of electroweak, heavy-flavor, and QCD measurements. Many of these results are one of a kind or represent the world's standard in precision. This article reviews the highlights of the SLD physics program, with an eye toward associated advances in experimental technique, and the contribution of these measurements to our dramatically improved present understanding of the standard model and its possible extensions.Comment: To appear in 2001 Annual Review of Nuclear and Particle Science; 78 pages, 31 figures; A version with higher resolution figures can be seen at http://www.slac.stanford.edu/pubs/slacpubs/8000/slac-pub-8985.html; Second version incorporates minor changes to the tex

    Weakly-Coupled Higgs Bosons and Precision Electroweak Physics

    Get PDF
    We examine the prospects for discovering and elucidating the weakly-coupled Higgs sector at future collider experiments. The Higgs search consists of three phases: (i) discovery of a Higgs candidate, (ii) verification of the Higgs interpretation of the signal, and (iii) precision measurements of Higgs sector properties. The discovery of one Higgs boson with Standard Model properties is not sufficient to expose the underlying structure of the electroweak symmetry breaking dynamics. It is critical to search for evidence for a non-minimal Higgs sector and/or new physics associated with electroweak symmetry breaking dynamics. An improvement in precision electroweak data at future colliders can play a useful role in confirming the theoretical interpretation of the Higgs search results

    Multiple hadron production in e+e- annihilation induced by heavy primary quarks. New analysis

    Full text link
    In this paper we present an analysis of the multiple hadron production induced by primary heavy quarks in e+e- annihilation with the account of most complete and corrected experimental data. In the framework of perturbative QCD, new theoretical bounds on the asymptotically constant differences of the multiplicities in processes with light and heavy quarks are given.Comment: 26 pages, 7 figures, to be published in Particles & Nucle

    Association of Blood Biomarkers With Acute Sport-Related Concussion in Collegiate Athletes: Findings From the NCAA and Department of Defense CARE Consortium

    Get PDF
    Importance: There is potential scientific and clinical value in validation of objective biomarkers for sport-related concussion (SRC). Objective: To investigate the association of acute-phase blood biomarker levels with SRC in collegiate athletes. Design, Setting, and Participants: This multicenter, prospective, case-control study was conducted by the National Collegiate Athletic Association (NCAA) and the US Department of Defense Concussion Assessment, Research, and Education (CARE) Consortium from February 20, 2015, to May 31, 2018, at 6 CARE Advanced Research Core sites. A total of 504 collegiate athletes with concussion, contact sport control athletes, and non-contact sport control athletes completed clinical testing and blood collection at preseason baseline, the acute postinjury period, 24 to 48 hours after injury, the point of reporting being asymptomatic, and 7 days after return to play. Data analysis was conducted from March 1 to November 30, 2019. Main Outcomes and Measures: Glial fibrillary acidic protein (GFAP), ubiquitin C-terminal hydrolase-L1 (UCH-L1), neurofilament light chain, and tau were quantified using the Quanterix Simoa multiplex assay. Clinical outcome measures included the Sport Concussion Assessment Tool-Third Edition (SCAT-3) symptom evaluation, Standardized Assessment of Concussion, Balance Error Scoring System, and Brief Symptom Inventory 18. Results: A total of 264 athletes with concussion (mean [SD] age, 19.08 [1.24] years; 211 [79.9%] male), 138 contact sport controls (mean [SD] age, 19.03 [1.27] years; 107 [77.5%] male), and 102 non-contact sport controls (mean [SD] age, 19.39 [1.25] years; 82 [80.4%] male) were included in the study. Athletes with concussion had significant elevation in GFAP (mean difference, 0.430 pg/mL; 95% CI, 0.339-0.521 pg/mL; P < .001), UCH-L1 (mean difference, 0.449 pg/mL; 95% CI, 0.167-0.732 pg/mL; P < .001), and tau levels (mean difference, 0.221 pg/mL; 95% CI, 0.046-0.396 pg/mL; P = .004) at the acute postinjury time point compared with preseason baseline. Longitudinally, a significant interaction (group × visit) was found for GFAP (F7,1507.36 = 16.18, P < .001), UCH-L1 (F7,1153.09 = 5.71, P < .001), and tau (F7,1480.55 = 6.81, P < .001); the interaction for neurofilament light chain was not significant (F7,1506.90 = 1.33, P = .23). The area under the curve for the combination of GFAP and UCH-L1 in differentiating athletes with concussion from contact sport controls at the acute postinjury period was 0.71 (95% CI, 0.64-0.78; P < .001); the acute postinjury area under the curve for all 4 biomarkers combined was 0.72 (95% CI, 0.65-0.79; P < .001). Beyond SCAT-3 symptom score, GFAP at the acute postinjury time point was associated with the classification of athletes with concussion from contact controls (β = 12.298; 95% CI, 2.776-54.481; P = .001) and non-contact sport controls (β = 5.438; 95% CI, 1.676-17.645; P = .005). Athletes with concussion with loss of consciousness or posttraumatic amnesia had significantly higher levels of GFAP than athletes with concussion with neither loss of consciousness nor posttraumatic amnesia at the acute postinjury time point (mean difference, 0.583 pg/mL; 95% CI, 0.369-0.797 pg/mL; P < .001). Conclusions and Relevance: The results suggest that blood biomarkers can be used as research tools to inform the underlying pathophysiological mechanism of concussion and provide additional support for future studies to optimize and validate biomarkers for potential clinical use in SRC

    Observation of single collisionally cooled trapped ions in a buffer gas

    Get PDF
    Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of light gases such as He and Ar and the destabilizing properties of heavier gases such as Xe are studied. A simple model is offered to explain the observed phenomenology.Comment: 5 pages, 4 figures, accepted for publication in Phys. Rev. A. Minor text and figure change

    Sub-milliarcsecond Imaging of Quasars and Active Galactic Nuclei. IV. Fine Scale Structure

    Get PDF
    We have used VLBA fringe visibility data obtained at 15 GHz to examine the compact structure in 250 extragalactic radio sources. For 171 sources in our sample, more than half of the total flux density seen by the VLBA remains unresolved on the longest baselines. There are 163 sources in our list with a median correlated flux density at 15 GHz in excess of 0.5 Jy on the longest baselines. For about 60% of the sources, we have at least one observation in which the core component appears unresolved (generally smaller than 0.05 mas) in one direction, usually transverse to the direction into which the jet extends. BL Lacs are on average more compact than quasars, while active galaxies are on average less compact. Also, in an active galaxy the sub-milliarcsecond core component tends to be less dominant. IDV sources typically have a more compact, more core-dominated structure on sub-milliarcsecond scales than non-IDV sources, and sources with a greater amplitude of intra-day variations tend to have a greater unresolved VLBA flux density. The objects known to be GeV gamma-ray loud appear to have a more compact VLBA structure than the other sources in our sample. This suggests that the mechanisms for the production of gamma-ray emission and for the generation of compact radio synchrotron emitting features are related. The brightness temperature estimates and lower limits for the cores in our sample typically range between 10^11 and 10^13 K, but they extend up to 5x10^13 K, apparently in excess of the equipartition brightness temperature, or the inverse Compton limit for stationary synchrotron sources. The largest component speeds are observed in radio sources with high observed brightness temperatures, as would be expected from relativistic beaming (abridged).Comment: 31 pages, 13 figures, 4 tables, accepted for publication in the Astronomical Journal; minor changes to the text are mad
    • …
    corecore