6 research outputs found

    Global Variation in Magnetic Resonance Imaging Quality of the Prostate

    Get PDF
    BACKGROUND: High variability in prostate MRI quality might reduce accuracy in prostate cancer detection. PURPOSE: To prospectively evaluate the quality of MRI scanners taking part in the quality control phase of the global PRIME (Prostate Imaging Using MRI ± Contrast Enhancement) trial using the Prostate Imaging Quality (PI-QUAL) standardized scoring system, give recommendations on how to improve the MRI protocols, and establish whether MRI quality could be improved by these recommendations. MATERIALS AND METHODS: In the prospective clinical trial (PRIME), for each scanner, centers performing prostate MRI submitted five consecutive studies and the MRI protocols (phase I). Submitted data were evaluated in consensus by two expert genitourinary radiologists using the PI-QUAL scoring system that evaluates MRI diagnostic quality using five points (1 and 2 = nondiagnostic; 3 = sufficient; 4 = adequate, 5 = optimal) between September 2021 and August 2022. Feedback was provided for scanners not achieving a PI-QUAL 5 score, and centers were invited to resubmit new imaging data using the modified protocol (phase II). Descriptive comparison of outcomes was made between the MRI scanners, feedback provided, and overall PI-QUAL scores. RESULTS: In phase I, 41 centers from 18 countries submitted a total of 355 multiparametric MRI studies from 71 scanners, with nine (13%) scanners achieving a PI-QUAL score of 3, 39 (55%) achieving a score of 4, and 23 (32%) achieving a score of 5. Of the 48 (n = 71 [68%]) scanners that received feedback to improve, the dynamic contrast-enhanced sequences were those that least adhered to the Prostate Imaging Reporting and Data System, version 2.1, criteria (44 of 48 [92%]), followed by diffusion-weighted imaging (20 of 48 [42%]) and T2-weighted imaging (19 of 48 [40%]). In phase II, 36 centers from 17 countries resubmitted revised studies, resulting in a total of 62 (n = 64 [97%]) scanners with a final PI-QUAL score of 5. CONCLUSION: Substantial variation in global prostate MRI acquisition parameters as a measure of quality was observed, particularly with DCE sequences. Basic evaluation and modifications to MRI protocols using PI-QUAL can lead to substantial improvements in quality. Clinical trial registration no. NCT0457184

    Comparing biparametric to multiparametric MRI in the diagnosis of clinically significant prostate cancer in biopsy-naive men (PRIME): a prospective, international, multicentre, non-inferiority within-patient, diagnostic yield trial protocol

    No full text
    Introduction Prostate MRI is a well-established tool for the diagnostic work-up for men with suspected prostate cancer (PCa). Current recommendations advocate the use of multiparametric MRI (mpMRI), which is composed of three sequences: T2-weighted sequence (T2W), diffusion-weighted sequence (DWI) and dynamic contrast-enhanced sequence (DCE). Prior studies suggest that a biparametric MRI (bpMRI) approach, omitting the DCE sequences, may not compromise clinically significant cancer detection, though there are limitations to these studies, and it is not known how this may affect treatment eligibility. A bpMRI approach will reduce scanning time, may be more cost-effective and, at a population level, will allow more men to gain access to an MRI than an mpMRI approach.Methods Prostate Imaging Using MRI±Contrast Enhancement (PRIME) is a prospective, international, multicentre, within-patient diagnostic yield trial assessing whether bpMRI is non-inferior to mpMRI in the diagnosis of clinically significant PCa. Patients will undergo the full mpMRI scan. Radiologists will be blinded to the DCE and will initially report the MRI using only the bpMRI (T2W and DWI) sequences. They will then be unblinded to the DCE sequence and will then re-report the MRI using the mpMRI sequences (T2W, DWI and DCE). Men with suspicious lesions on either bpMRI or mpMRI will undergo prostate biopsy. The main inclusion criteria are men with suspected PCa, with a serum PSA of ≤20 ng/mL and without prior prostate biopsy. The primary outcome is the proportion of men with clinically significant PCa detected (Gleason score ≥3+4 or Gleason grade group ≥2). A sample size of at least 500 patients is required. Key secondary outcomes include the proportion of clinically insignificant PCa detected and treatment decision.Ethics and dissemination Ethical approval was obtained from the National Research Ethics Committee West Midlands, Nottingham (21/WM/0091). Results of this trial will be disseminated through peer-reviewed publications. Participants and relevant patient support groups will be informed about the results of the trial.Trial registration number NCT04571840

    Global Variation in Magnetic Resonance Imaging Quality of the Prostate

    Get PDF
    Background High variability in prostate MRI quality might reduce accuracy in prostate cancer detection. Purpose To prospectively evaluate the quality of MRI scanners taking part in the quality control phase of the global PRIME (Prostate Imaging Using MRI ± Contrast Enhancement) trial using the Prostate Imaging Quality (PI-QUAL) standardized scoring system, give recommendations on how to improve the MRI protocols, and establish whether MRI quality could be improved by these recommendations. Materials and Methods In the prospective clinical trial (PRIME), for each scanner, centers performing prostate MRI submitted five consecutive studies and the MRI protocols (phase I). Submitted data were evaluated in consensus by two expert genitourinary radiologists using the PI-QUAL scoring system that evaluates MRI diagnostic quality using five points (1 and 2 = nondiagnostic; 3 = sufficient; 4 = adequate, 5 = optimal) between September 2021 and August 2022. Feedback was provided for scanners not achieving a PI-QUAL 5 score, and centers were invited to resubmit new imaging data using the modified protocol (phase II). Descriptive comparison of outcomes was made between the MRI scanners, feedback provided, and overall PI-QUAL scores. Results In phase I, 41 centers from 18 countries submitted a total of 355 multiparametric MRI studies from 71 scanners, with nine (13%) scanners achieving a PI-QUAL score of 3, 39 (55%) achieving a score of 4, and 23 (32%) achieving a score of 5. Of the 48 (n = 71 [68%]) scanners that received feedback to improve, the dynamic contrast-enhanced sequences were those that least adhered to the Prostate Imaging Reporting and Data System, version 2.1, criteria (44 of 48 [92%]), followed by diffusion-weighted imaging (20 of 48 [42%]) and T2-weighted imaging (19 of 48 [40%]). In phase II, 36 centers from 17 countries resubmitted revised studies, resulting in a total of 62 (n = 64 [97%]) scanners with a final PI-QUAL score of 5. Conclusion Substantial variation in global prostate MRI acquisition parameters as a measure of quality was observed, particularly with DCE sequences. Basic evaluation and modifications to MRI protocols using PI-QUAL can lead to substantial improvements in quality. Clinical trial registration no. NCT04571840 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Almansour and Chernyak in this issue
    corecore