    Gamma emission tomosynthesis based on an automated slant hole collimation system

    Get PDF
    The imaging capabilities of radioisotope molecular imaging systems are limited by their ring geometry and by the object-to-detector distance, which impairs spatial resolution, efficiency and image quality. These detection capabilities could be enhanced by performing acquisitions with dedicated gamma cameras placed in close proximity to the object that has to be examined. The main aim of this work is to develop a compact camera suitable for detecting small and low-contrast lesions, with a higher detection efficiency than conventional SPECT, through a gamma emission tomosynthesis method. In this contribution a prototype of a new automated slant hole collimator, coupled to a small Field of View (FoV) gamma camera, is presented. The proposed device is able to acquire planar projection images at different angles without rotating around the patient body; these projection images are then three-dimensional reconstructed. Therefore, in order to perform the volumetric reconstruction of the studied object, the traditional Back Projection (BP) reconstruction is compared with the Shift And Add (SAA) method. In order to verify the effectiveness of the technique and to test the image reconstruction algorithms, a Monte Carlo simulation, based on the GEANT4 code, was implemented. The method was also validated by a set of experimental measurements. The discussed device is designed to work in patient proximity for detecting lesions placed at a distances ranged from 0 to 8 cm, thus allowing few millimeters planar resolutions and sagittal resolution of about 2 cm. The new collimation method implies high-resolution capabilities demonstrated by reconstructing the projection images through the BP and the SAA methods. The latter is simpler than BP and produces comparable spatial resolutions with respect to the traditional tomographic method, while preserving the image counts. © 2015 IOP Publishing Ltd and Sissa Medialab srl

    Innovative LuYAP:Ce array for PET imaging

    Get PDF
    We present an imaging characterization of a 10 x 10 LuYAP array (2 x 2 x 10 mm3 pixels) with an innovative dielectric coating insulation (0.015 mm thick), in view of its possible use in a gamma camera for imaging positron emission tomography (PET) or in similar applications, e.g. as Îł-prompt detector in hadron therapy. The particular assembly of this array was realized in order to obtain a packing fraction of 98%, improving detection efficiency and light collection. For imaging purpose, the array has been coupled with a selected Hamamatsu H10966-100 Multi Anode Photomultiplier read out by a customized 64 independent channels electronics. This tube presents a superbialkali photocathode with 38% of quantum efficiency, permitting to enhance energy resolution and consequently image quality. A pixel identification of about 0.5 mm at 662 keV was obtained, highlighting the potentiality of this detector in PET application

    Pharmacological effects of 3-iodothyronamine (T1AM) in mice include facilitation of memory acquisition and retention and reduction of pain threshold

    Get PDF
    BACKGROUND AND PURPOSE: 3-Iodothyronamine (T1AM), an endogenous derivative of thyroid hormones, is regarded as a rapid modulator of behaviour and metabolism. To determine whether brain thyroid hormone levels contribute to these effects, we investigated the effect of central administration of T1AM on learning and pain threshold of mice either untreated or pretreated with clorgyline (2.5 mg•kg-1, i.p.), an inhibitor of amine oxidative metabolism. EXPERIMENTAL APPROACH: T1AM (0.13, 0.4, 1.32 and 4 mg•kg-1) or vehicle was injected i.c.v. into male mice, and after 30 min their effects on memory acquisition capacity, pain threshold and curiosity were evaluated by the following tests: passive avoidance, licking latency on the hot plate and movements on the hole-board platform. Plasma glycaemia was measured using a glucorefractometer. Brain levels of triiodothyroxine (T3), thyroxine (T4) and T1AM were measured by HPLC coupled to tandem MS. ERK1/2 activation and c-fos expression in different brain regions were evaluated by Western blot analysis. RESULTS: T1AM improved learning capacity, decreased pain threshold to hot stimuli, enhanced curiosity and raised plasma glycaemia in a dose-dependent way, without modifying T3 and T4 brain concentrations. T1AM effects on learning and pain were abolished or significantly affected by clorgyline, suggesting a role for some metabolite(s), or that T1AM interacts at the rapid desensitizing target(s). T1AM activated ERK in different brain areas at lower doses than those effective on behaviour. CONCLUSIONS AND IMPLICATIONS: T1AM is a novel memory enhancer. This feature might have important implications for the treatment of endocrine and neurodegenerative-induced memory disorders

    A Novel Method for Y Photons Depth of Interaction Discrimination on Monolithic LYSO Crystals for Brain PET/MRI

    Get PDF
    The MindView European Project pursues the development of a high efficiency and high resolution brain dedicated PET detector, simultaneously working with a Magnetic Resonance Imaging (MRI) system. Since the PET scanner is based on a small diameter ring and on thick monolithic scintillation crystals to assess high efficiency, the parallax error related to off-center positron annihilation is a critical issue. The Depth of Interaction (DoI) discrimination can reduce the blurring due to this phenomenon. In this work, we propose a novel DoI estimator, based on the ratio of the integral of scintillation light distribution to its maximum (named N/I). In a preliminary way, by means of Monte Carlo simulation, we have validated the correlation between this parameter and the DoI. Furthermore, we have experimentally tested the capability of such DoI estimator on a monolithic 20mm-thick LYSO crystal optically coupled to a 12x12 silicon photomultipliers (SiPMs) array. Thanks to the proposed method, it is possible to select interaction events coming from different depths of the crystal. The DoI discrimination capability has been confirmed by using a collimated slanted pencil-beam: the proposed estimator allows to produce different images coming from events belonging to different depths of the crystal. From the experimental results a DoI discrimination resolution ranging from 4mm to 6mm has been obtained. The proposed method is expected to reduce the parallax error and, consequently, the width of lines of response coming from off- center positron annihilation of about 70% respect to the method without DoI discrimination

    Practice patterns and 90-day treatment-related morbidity in early-stage cervical cancer

    Get PDF
    To evaluate the impact of the Laparoscopic Approach to Cervical Cancer (LACC) Trial on patterns of care and surgery-related morbidity in early-stage cervical cancer

    Pulse-Height and 2-D Charge-Spread Single-Pixels Studies on a LuYAP:Ce Scintillation Array

    Get PDF
    The present work deals with a 10 × 10 array of (Lu0.7Y0.3)AP:Ce 2 × 2 × 10 mm3 pixels, manufactured by Crytur (Cz), that has been utilized in a previous paper. The crystal-array has been coupled to an 8 × 8 anodes H10966 model Hamamatsu (Jp) Position-Sensitive Photo Multiplier Tube (PSPMT) connected to electronics for single events scintillation read-out. The response of such a detector has been studied under Co-57, or Ba-133, or Cs-137 gamma-ray emissions, as well as with Lu-176 self-activity only. The present work is aimed at characterizing the individual crystal-pixels’ single-event responses in terms of pulse-height and of spreads of the 2-D charge-distributions. In particular, the charge-spread characterization pointed out several defects in the crystal-array assembly, not detected by usual pulse-height studies. The diagnostic method based on charge-spread analysis seems also well suited for scintillation array characterizations for gamma-ray detectors studies, as well as for quality controls of such pixelated devices during the lifetime of systems in the field of radionuclide medical imaging (SPECT and PET). The method is also appropriate for other applications where gamma-ray spectroscopy is required, like nuclear physics, astrophysics, astroparticle physics, homeland security, and non-proliferation

    The use of cadmium telluride detectors for the qualitative analysis of diagnostic x-ray spectra

    No full text
    A method is introduced for the evaluation of x-ray spectra from x-ray machines operating in the range 50-100 kVp using a cadmium telluride (CdTe) detector with low detection efficiency. The pulse height distribution obtained with this kind of detector does not represent the true photon spectra owing to the presence of K-escape, Compton scattering, etc.; these effects were evaluated using a Monte Carlo method. A stripping procedure is described for implementation on a Univac 1100/82 computer. The validity of the authors' method was finally tested by comparison with experimental results obtained with a Ge detector and with data from the literature; the results are in good agreement with published data
    • …