44 research outputs found

    Hypertrophic cardiomyopathy and ultra-endurance running - two incompatible entities?

    Get PDF
    Regular and prolonged exercise is associated with increased left ventricular wall thickness that can overlap with hypertrophic cardiomyopathy (HCM). Differentiating physiological from pathological hypertrophy has important implications, since HCM is the commonest cause of exercise-related sudden cardiac death in young individuals. Most deaths have been reported in intermittent 'start-stop' sports such as football (soccer) and basketball. The theory is that individuals with HCM are unable to augment stroke volume sufficiently to meet the demands of endurance sports and are accordingly 'selected-out' of participation in such events. We report the case of an ultra-endurance athlete with 25 years of > 50 km competitive running experience, with genetically confirmed HCM; thereby demonstrating that these can be two compatible entities

    Prognostic Significance of Myocardial Fibrosis in Hypertrophic Cardiomyopathy

    Get PDF
    ObjectivesWe investigated the significance of fibrosis detected by late gadolinium enhancement cardiovascular magnetic resonance for the prediction of major clinical events in hypertrophic cardiomyopathy (HCM).BackgroundThe role of myocardial fibrosis in the prediction of sudden death and heart failure in HCM is unclear with a lack of prospective data.MethodsWe assessed the presence and amount of myocardial fibrosis in HCM patients and prospectively followed them for the development of morbidity and mortality in patients over 3.1 ± 1.7 years.ResultsOf 217 consecutive HCM patients, 136 (63%) showed fibrosis. Thirty-four of the 136 patients (25%) in the fibrosis group but only 6 of 81 (7.4%) patients without fibrosis reached the combined primary end point of cardiovascular death, unplanned cardiovascular admission, sustained ventricular tachycardia or ventricular fibrillation, or appropriate implantable cardioverter-defibrillator discharge (hazard ratio [HR]: 3.4, p = 0.006). In the fibrosis group, overall risk increased with the extent of fibrosis (HR: 1.18/5% increase, p = 0.008). The risk of unplanned heart failure admissions, deterioration to New York Heart Association functional class III or IV, or heart failure-related death was greater in the fibrosis group (HR: 2.5, p = 0.021), and this risk increased as the extent of fibrosis increased (HR: 1.16/5% increase, p = 0.017). All relationships remained significant after multivariate analysis. The extent of fibrosis and nonsustained ventricular tachycardia were univariate predictors for arrhythmic end points (sustained ventricular tachycardia or ventricular fibrillation, appropriate implantable cardioverter-defibrillator discharge, sudden cardiac death) (HR: 1.30, p = 0.014). Nonsustained ventricular tachycardia remained an independent predictor of arrhythmic end points after multivariate analysis, but the extent of fibrosis did not.ConclusionsIn patients with HCM, myocardial fibrosis as measured by late gadolinium enhancement cardiovascular magnetic resonance is an independent predictor of adverse outcome. (The Prognostic Significance of Fibrosis Detection in Cardiomyopathy; NCT00930735

    Troponin release following endurance exercise: is inflammation the cause? a cardiovascular magnetic resonance study

    Get PDF
    Background: The aetiology and clinical significance of troponin release following endurance exercise is unclear but may be due to transient myocardial inflammation. Cardiovascular magnetic resonance (CMR) affords us the opportunity to evaluate the presence of myocardial inflammation and focal fibrosis and is the ideal imaging modality to study this hypothesis. We sought to correlate the relationship between acute bouts of ultra endurance exercise leading to cardiac biomarkers elevation and the presence of myocardial inflammation and fibrosis using CMR.Methods: 17 recreation athletes (33.5 +/- 6.5 years) were studied before and after a marathon run with troponin, NTproBNP, and CMR. Specific imaging parameters to look for inflammation included T2 weighted images, and T1 weighted spin-echo images before and after an intravenous gadolinium-DTPA to detect myocardial hyperemia secondary to inflammation. Late gadolinium imaging was performed (LGE) to detect any focal regions of replacement fibrosis.Results: Eleven of the 17 participant had elevations of TnI above levels of cut off for myocardial infarction 6 hrs after the marathon (0.075 +/- 0.02, p = 0.007). Left ventricular volumes were reduced post marathon and a small increase in ejection fraction was noted (64 +/- 1% pre, 67 +/- 1.2% post, P = 0.014). Right ventricular volumes, stroke volume, and ejection fraction were unchanged post marathon. No athlete fulfilled criteria for myocardial inflammation based on current criteria. No regions of focal fibrosis were seen in any of the participants.Conclusion: Exercise induced cardiac biomarker release is not associated with any functional changes by CMR or any detectable myocardial inflammation or fibrosis

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Search for eccentric black hole coalescences during the third observing run of LIGO and Virgo

    Get PDF
    Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass M>70 M⊙) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities 0<e≤0.3 at 0.33 Gpc−3 yr−1 at 90\% confidence level

    Search for gravitational-lensing signatures in the full third observing run of the LIGO-Virgo network

    Get PDF
    Gravitational lensing by massive objects along the line of sight to the source causes distortions of gravitational wave-signals; such distortions may reveal information about fundamental physics, cosmology and astrophysics. In this work, we have extended the search for lensing signatures to all binary black hole events from the third observing run of the LIGO--Virgo network. We search for repeated signals from strong lensing by 1) performing targeted searches for subthreshold signals, 2) calculating the degree of overlap amongst the intrinsic parameters and sky location of pairs of signals, 3) comparing the similarities of the spectrograms amongst pairs of signals, and 4) performing dual-signal Bayesian analysis that takes into account selection effects and astrophysical knowledge. We also search for distortions to the gravitational waveform caused by 1) frequency-independent phase shifts in strongly lensed images, and 2) frequency-dependent modulation of the amplitude and phase due to point masses. None of these searches yields significant evidence for lensing. Finally, we use the non-detection of gravitational-wave lensing to constrain the lensing rate based on the latest merger-rate estimates and the fraction of dark matter composed of compact objects

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM
    corecore