210 research outputs found

    An automated system for liquid-liquid extraction in monosegmented flow analysis

    Get PDF
    An automated system to perform liquid-liquid extraction in monosegmented flow analysis is described. The system is controlled by a microcomputer that can track the localization of the aqueous monosegmented sample in the manifold. Optical switches are employed to sense the gas-liquid interface of the air bubbles that define the monosegment. The logical level changes, generated by the switches, are flagged by the computer through a home-made interface that also contains the analogue-to-digital converter for signal acquisition. The sequence of operations, necessary for a single extraction or for concentration of the analyte in the organic phase, is triggered by these logical transitions. The system was evaluated for extraction of Cd(II), Cu(II) and Zn(II) and concentration of Cd(II) from aqueous solutions at pH 9.9 (NH3/NH4Cl buffer) into chloroform containing PAN (1-(2-pyridylazo)-2-naphthol) . The results show a mean repeatability of 3% (rsd) for a 2.0 mg l-1 Cd(II) solution and a linear increase of the concentration factor for a 0.5mg l-1 Cd(II) solution observed for up to nine extraction cycles

    Automatic determination of mercury in samples of environmental interest

    Get PDF
    An automatic flow injection (FI) system for the determination of mercury was developed using a commercial Gold vapour atomic absorption spectrophotometer (CVAAS). Control and data acquisition in the FI system was done with an IBM-PC 286 XI compatible microcomputer and a home-made interface, using software written in QuickBasic 4.5. Mercury content was determined by: sampling using a combination of four electromechanical three-way poly(tetrafluoroethylene) valves; separation of the dissolved reduced mercury in a gas/liquid separation cell using nitrogen as carrier, followed by amalgamation of the stripped metal on a gold wire column; after stripping the metal, cleaning the separation cell using vacuum, which was controlled by a three-way electromechanical valve; heating the gold wire column automatically to release the amalgamated mercury using an external nichrome wire coil; storing the output signals automatically to calculate the final mercury concentration, using commercially available software. The optimized system presents a detection limit of 5.3 ng l(-1) of mercury (30 pg absolute) using 5.7 ml (three injections of 1900 mu l of the sample) with an analytical frequency of six samples per hour and reproducibility of 5%. The procedure was used to determine mercury in fish, hair and natural water samples.18619319

    Automation of a plane grating spectrograph

    Get PDF
    A Zeiss model PGS-2 plane grating spectrograph was automated by replacing its photograph film detection system with an EGG-Reticon 1024S photodiode array (PDA) and by controlling the main instrument functions through the use of a home-made interface connected to a microcomputer. The array was cooled by four Peltier elements to allow integration of the emitted light for up to 40 s. The interface performs data acquisition from the sensor array, controls the grating position and the excitation source. A QuickBasic 4.5 program manages the interface, for data storage and treatment, and allows a graphical display and user-friendly interaction. Results show an absolute standard deviation for the wavelength localization of +/- 0.036 nm, and a spectral resolution of 0.05 nm at 443 nm when a 651 grooves/mm grating is employed. In each scan, the sensor array can collect data in a 18.7 nm wide window. Sensitivity was inferred from experimental data that showed an accurate localization of emission lines for Sn and Cu present in metal alloys at 0.006 and 0.03%, respectively. Quantitative results obtained for determination of Mn in steel samples and Ph in aqueous solution are also presented.18171

    Experimento didático de quimiometria para calibração multivariada na determinação de paracetamol em comprimidos comerciais utilizando espectroscopia no infravermelho próximo: um tutorial, parte II.

    Get PDF
    The aim of this manuscript was to show the basic concepts and practical application of Partial Least Squares (PLS) as a tutorial, using the Matlab computing environment for beginners, undergraduate and graduate students. As a practical example, the determination of the drug paracetamol in commercial tablets using Near-Infrared (NIR) spectroscopy and Partial Least Squares (PLS) regression was shown, an experiment that has been successfully carried out at the Chemical Institute of Campinas State University for chemistry undergraduate course students to introduce the basic concepts of multivariate calibration in a practical way

    Automatic determination of mercury samples of environmental interest in

    Get PDF
    An automatic flow injection (FI) system for the determination of mercury was developed using a commercial cold vapour atomic absorption spectrophotometer (CVAAS). Control Pre-concentration procedures have a high level of reliability and applicability due to the lower detection limi

    Gran method for end point anticipation in monosegmented flow titration

    Get PDF
    An automatic potentiometric monosegmented flow titration procedure based on Gran linearisation approach has been developed. The controlling program can estimate the end point of the titration after the addition of three or four aliquots of titrant. Alternatively, the end point can be determined by the second derivative procedure. In this case, additional volumes of titrant are added until the vicinity of the end point and three points before and after the stoichiometric point are used for end point calculation. The performance of the system was assessed by the determination of chloride in isotonic beverages and parenteral solutions. The system employs a tubular Ag2S/AgCl indicator electrode. A typical titration, performed according to the IUPAC definition, requires only 60 mL of sample and about the same volume of titrant (AgNO3) solution. A complete titration can be carried out in 1 - 5 min. The accuracy and precision (relative standard deviation of ten replicates) are 2% and 1% for the Gran and 1% and 0.5% for the Gran/derivative end point determination procedures, respectively. The proposed system reduces the time to perform a titration, ensuring low sample and reagent consumption, and full automatic sampling and titrant addition in a calibration-free titration protocol.Este trabalho descreve o uso do método de linearização de Gran em titulações em fluxo monossegmentado com detecção potenciométrica. O programa de controle pode estimar o ponto final após a adição de três ou quatro alíquotas de titulante. Alternativamente, o ponto final da titulação pode ser determinado pelo método da segunda derivada. Neste caso, alíquotas adicionais de titulante são adicionadas até a proximidade do ponto final e três pontos antes e após o ponto estequiométrico são usados para o cálculo de ponto final. O desempenho do sistema foi avaliado pela determinação de cloreto em soluções isotônicas e parenterais. O sistema emprega um eletrodo indicador tubular de Ag2S/AgCl. Uma titulação típica, realizada de acordo com a definição IUPAC, requer apenas 60 mL de amostra e aproximadamente o mesmo volume de titulante (AgNO3). Uma titulação completa pode ser realizada entre 1 e 5 min. Foram obtidas exatidão e precisão (desvio padrão relativo de 10 replicatas) de 2% e 1% para o método de Gran e 1% e 0,5% para o método de Gran associado ao método da segunda derivada, respectivamente. O sistema proposto reduz o tempo para realizar uma titulação, com baixo consumo de amostra e reagente, além de possibilitar uma amostragem automática completa e adição de titulante sem a necessidade de uma etapa de calibração.111115Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES

    Design and development of a multichannel potentiometer for monitoring an electrode array and its application in flow analysis

    Get PDF
    A versatile potentiometer that works with electrode arrays in flow injection and/or monosegmented flow systems is described. The potentiometer is controlled by a microcomputer that allows individual, sequential multiplexed or random accesses to eight electrodes while employing only one reference electrode. The instrument was demonstrated by monitoring an array of seven flow-through ion-selective electrodes for Ag+ and for three electrodes for Cl-, Ca2+ and K+. The figures of merit of the individual and multiplexed (summed) readings of the electrode array were compared. The absolute standard deviation of the measurements made by summing the potential of two or more electrodes was maintained constant, thus improving the precision of the measurements. This result shows that an attempt to combine the signals of the electrodes to produce a more intense signal in the Hadamard strategy is feasible and accompanied by a proportional improvement in the precision of individual measurements. The preliminary tests suggest that the system can allow for 270 determinations per hour, with a linear range from 1.0 × 10-2 to 1.0 × 10-4 mol l-1 for the three di¡erent analytes. Detection limits were estimated as 3.1 × 10-5, 3.0 × 10-6 and 1.0 × 10-5 mol l-1 for Cl-, Ca2+ and K+, respectively
    corecore