174 research outputs found

    Development of Micro-Heaters with Optimized Temperature Compensation Design for Gas Sensors

    Get PDF
    One of the key components of a chemical gas sensor is a MEMS micro-heater. Micro-heaters are used in both semiconductor gas sensors and NDIR gas sensors; however they each require different heat dissipation characteristics. For the semiconductor gas sensors, a uniform temperature is required over a wide area of the heater. On the other hand, for the NDIR gas sensor, the micro-heater needs high levels of infrared radiation in order to increase sensitivity. In this study, a novel design of a poly-Si micro-heater is proposed to improve the uniformity of heat dissipation on the heating plate. Temperature uniformity of the micro-heater is achieved by compensating for the variation in power consumption around the perimeter of the heater. With the power compensated design, the uniform heating area is increased by 2.5 times and the average temperature goes up by 40 °C. Therefore, this power compensated micro-heater design is suitable for a semiconductor gas sensor. Meanwhile, the poly-Si micro-heater without compensation shows a higher level of infrared radiation under equal power consumption conditions. This indicates that the micro-heater without compensation is more suitable for a NDIR gas sensor. Furthermore, the micro-heater shows a short response time of less than 20ms, indicating a very high efficiency of pulse driving

    Isolated primary schwannoma arising on the colon: report of two cases and review of the literature

    Get PDF
    Primary schwannoma of the large intestine is an extremely rare neoplasm. Here, we report two cases of colonic schwannoma confirmed pathologically after laparoscopic resection. A 52-year-old female and a 59-year-old female were referred by their general practitioners to our coloproctologic clinic for further evaluation and management of colonic submucosal masses. Colonoscopies performed in our institution revealed round submucosal tumors with a smooth and intact mucosa in the mid-ascending and descending colon, respectively. Computed tomography (CT) scans showed an enhancing soft tissue mass measuring 2 × 2 cm in the right colon and well-defined soft tissue nodule measuring 1.5 × 1.7 cm in the proximal descending colon, respectively. We performed laparoscopic right hemicolectomy and segmental left colectomy under the preoperative impression of gastrointestinal stromal tumors. Two cases were both diagnosed to be benign schwannoma of the colon after immunohistochemical stains (S-100 (+), smooth muscle actin (-), CD117 (-), and CD34 (-))

    Management of Cerebrospinal Fluid Leakage by Pump-Regulated Volumetric Continuous Lumbar Drainage Following Anterior Cervical Decompression and Fusion for Ossification of the Posterior Longitudinal Ligament

    Get PDF
    Objective Cerebrospinal fluid (CSF) leakage is a major concern related to anterior cervical decompression and fusion for ossification of the posterior longitudinal ligament (OPLL). We propose a management algorithm for CSF leakage following anterior cervical decompression and fusion for OPLL involving the use of pump-regulated volumetric continuous lumbar drainage. Methods We retrospectively reviewed patients who underwent anterior cervical decompression and fusion for OPLL and were managed with the proposed algorithm between March 2018 and July 2022. The proposed management algorithm for CSF leakage by pump-regulated volumetric continuous lumbar drainage was as follows. On exposure of the arachnoid membrane with or without CSF leakage, a dural sealant patch was applied to manage the dural defect. In case of persistent CSF leakage despite application of the dural sealant patch, patients underwent pump-regulated volumetric continuous lumbar drainage. Results Fifty-one patients were included in the study. CSF leakage occurred in 14 patients. Of these 14 patients, 9 patients underwent lumbar drain insertion according to the proposed management algorithm. Successful resolution of CSF leakage was observed in 8 of the 9 patients who underwent lumbar drainage. All patients were encouraged to ambulate without concern of CSF overdrainage due to gravity, because it could be avoided with pump-regulated volumetric continuous CSF drainage. Therefore, complications associated with absolute bed rest or CSF overdrainage were not observed. Conclusion The proposed management algorithm with pump-regulated volumetric continuous lumbar drainage showed safety and efficacy for management of CSF leakage following anterior decompression and fusion for OPLL

    Clinical significance of preoperative serum vascular endothelial growth factor, interleukin-6, and C-reactive protein level in colorectal cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Angiogenesis is a multistep process in which many growth factors and cytokines have an essential role. Vascular endothelial growth factor (VEGF) is a potent angiogenic agent that acts as a specific mitogen for vascular endothelial cells through specific cell surface receptors. The interleukin-6 (IL-6) pathway is another mechanism linking angiogenesis to malignancy. C-reactive protein (CRP), a representative marker for inflammation, is known for its association with disease progression in many cancer types. The aim of this study was to determine preoperative serum levels of VEGF, IL-6, and CRP in colorectal carcinoma, and to correlate them with disease status and prognosis.</p> <p>Methods</p> <p>A 132 of 143 patients who underwent curative resection for colorectal cancer were enrolled in this study. 11 patients with resection margin positive were excluded. Factors considered in analysis of the relationship between VEGF, IL-6, and CRP and histological findings. Patient prognosis was investigated. Serum levels of VEGF and IL-6 were assessed using Enzyme-Linked Immuno-Sorbent Assay (ELISA), and CRP was measured using immunoturbidimetry.</p> <p>Results</p> <p>Median follow-up duration was 18.53 months (range 0.73-43.17 months) and median age of the patients was 62 years (range, 26-83 years). Mean and median levels of VEGF and CRP in colorectal cancer were significantly higher than in the normal control group; 608 vs. 334 pg/mL and 528 (range 122-3242) vs. 312 (range 16-1121) (<it>p </it>< 0.001); 1.05 mg/dL vs. 0.43 mg/dL and 0.22 (range 0.00-18.40) vs. 0.07 (range 0.02-6.94) (<it>p </it>= 0.002), respectively. However mean and median level of IL-6 in patients were not significantly higher than in control; 14.33 pg/mL vs. 5.65 pg/mL and 6.00 (range 1.02-139.17) vs. 5.30 (4.50-13.78) (<it>p </it>= 0.327). Although IL-6 and CRP levels were not correlated with other pathological findings, VEGF level was significantly correlated with tumor size (<it>p </it>= 0.012) and CEA (<it>p </it>= 0.038). When we established the cutoff value for VEGF (825 pg/mL), IL-6 (8.09 pg/mL), and CRP (0.51 mg/dL) by Receiver Operating Characteristic (ROC) curve, we noted that high VEGF levels tended to reduce overall survival (<it>p </it>= 0.053), but not significantly. However, IL-6 and CRP demonstrated no significance with regard to disease free survival (<it>p </it>= 0.531, <it>p </it>= 0.701, respectively) and overall survival (<it>p </it>= 0.563, <it>p </it>= 0.572, respectively). Multivariate analysis showed that VEGF (<it>p </it>= 0.032), CEA (<it>p </it>= 0.012), lymph node metastasis (<it>p </it>= 0.002), and TNM stage (<it>p </it>= 0.025) were independently associated with overall survival.</p> <p>Conclusions</p> <p>Preoperative serum VEGF and CRP level increased in colorectal cancer patients. High VEGF level has been proposed as a poor prognostic factor for overall survival in patients with colorectal cancer.</p

    Sacropelvic Fixation for Adult Deformity Surgery Comparing Iliac Screw and Sacral 2 Alar-Iliac Screw Fixation: Systematic Review and Updated Meta-Analysis

    Get PDF
    Objective Two commonly used techniques for spinopelvic fixation in adult deformity surgery are iliac screw (IS) and sacral 2 alar-iliac screw (S2AI) fixations. In this article, we systematically meta-analyzed the complications of sacropelvic fixation for adult deformity surgery comparing IS and S2AI. Methods The PubMed, Embase, Web of Science, and Cochrane clinical trial databases were systematically searched until March 29, 2023. The proportion of postoperative complications, including implant failure, revision, screw prominence, and wound complications after sacropelvic fixation, were pooled with a random-effects model. Subgroup analyses for the method of sacropelvic fixation were conducted. Results Ten studies with a total of 1,931 patients (IS, 925 patients; S2AI, 1,006 patients) were included. The pooled proportion of implant failure was not statistically different between the IS and S2AI groups (21.9% and 18.9%, respectively) (p = 0.59). However, revision was higher in the IS group (21.0%) than that in the S2AI group (8.5%) (p = 0.02). Additionally, screw prominence was higher in the IS group (9.6%) than that in the S2AI group (0.0%) (p < 0.01), and wound complication was also higher in the IS group (31.7%) than that in the S2AI group (3.9%) (p < 0.01). Conclusion IS and S2AI fixations showed that both techniques had similar outcomes in terms of implant failure. However, S2AI was revealed to have better outcomes than IS in terms of revision, screw prominence, and wound complications

    Transmembrane topology and oligomeric nature of an astrocytic membrane protein, MLC1

    Get PDF
    MLC1 is a membrane protein mainly expressed in astrocytes, and genetic mutations lead to the development of a leukodystrophy, megalencephalic leukoencephalopathy with subcortical cysts disease. Currently, the biochemical properties of the MLC1 protein are largely unknown. In this study, we aimed to characterize the transmembrane (TM) topology and oligomeric nature of the MLC1 protein. Systematic immunofluorescence staining data revealed that the MLC1 protein has eight TM domains and that both the N- and C-terminus face the cytoplasm. We found that MLC1 can be purified as an oligomer and could form a trimeric complex in both detergent micelles and reconstituted proteoliposomes. Additionally, a single-molecule photobleaching experiment showed that MLC1 protein complexes could consist of three MLC1 monomers in the reconstituted proteoliposomes. These results can provide a basis for both the high-resolution structural determination and functional characterization of the MLC1 protein.1

    Multiple human papillomavirus infection is associated with high-risk infection in male genital warts in Ulsan, Korea

    Get PDF
    Further understanding of male human papillomavirus (HPV) infection is necessary to prevent infection in men, as well as transmission to women. In our current study, we investigated patterns of HPV infection and genotype distributions in male genital warts using the Anyplex II HPV28 Detection kit. We reviewed the medical records of 80 male patients who presented to 5 neighborhood clinics in Ulsan, Korea, for the treatment of genital warts between April 2014 and January 2015. All patients underwent HPV genotyping. The prevalence and characteristics of HPV infection were analyzed, and the patterns of HPV infection according to age were assessed. Among the study patients, 13 (16.3%) were negative for HPV infection, 46 (57.3%) were infected with low-risk HPV, and 21 (26.3%) were infected with high-risk HPV. Patients with multiple HPV infection were more likely to have high-risk HPV infection (P = 0.001). The prevalence of HPV infection was much higher in samples obtained by tissue excision due to a definite lesion (P = 0.001). There were no differences in high-risk HPV infection (P = 0.459), multiple HPV infection (P = 0.185), and recurrence at diagnosis (P = 0.178) according to age. HPV-6 and HPV-11 were the most common type overall (39.7% and 13.8%, respectively). HPV- 16 and HPV-18 were the most common high-risk infections (both 3.4%). HPV infection is not only commonly encountered in male genital warts, but is also accompanied by highrisk HPV and multiple infections. &amp;#169; 2016 The Korean Academy of Medical Sciencesopen
    corecore