73 research outputs found

    3D motion analysis applying intertial sensing

    Get PDF
    Small inertial sensors like accelerometers and gyroscopes are more and more used in ambulatory motion analysis (Busseral. 1998; Baten et al. 2000; Veltink et al. 2003). Typically, angular orientation of a body segment is determined by integrating the output from the angular rate sensors strapped on the segment

    Ambulatory human motion tracking by fusion of inertial and magnetic sensing with adaptive actuation

    Get PDF
    Over the last years, inertial sensing has proven to be a suitable ambulatory alternative to traditional human motion tracking based on optical position measurement systems, which are generally restricted to a laboratory environment. Besides many advantages, a major drawback is the inherent drift caused by integration of acceleration and angular velocity to obtain position and orientation. In addition, inertial sensing cannot be used to estimate relative positions and orientations of sensors with respect to each other. In order to overcome these drawbacks, this study presents an Extended Kalman Filter for fusion of inertial and magnetic sensing that is used to estimate relative positions and orientations. In between magnetic updates, change of position and orientation are estimated using inertial sensors. The system decides to perform a magnetic update only if the estimated uncertainty associated with the relative position and orientation exceeds a predefined threshold. The filter is able to provide a stable and accurate estimation of relative position and orientation for several types of movements, as indicated by the average rms error being 0.033 m for the position and 3.6 degrees for the orientation

    A preliminary investigation of the use of inertial sensing technology for the measurement of hip rotation asymmetry in horse riders

    Get PDF
    This study investigated the use of inertial sensing technology as an indicator of asymmetry in horse riders, evidenced by discrepancies in the angle of external rotation of the hip joint. Twelve horse and rider combinations were assessed with the rider wearing the XsensTM MVN inertial motion capture suit. Asymmetry (left vs right) was revealed in mean hip external rotation of all riders, with values ranging from 1° to 27°, and 83% showed greater external rotation of the right hip. This study represents novel use of inertial sensing equipment in its application to the measurement of rider motion patterns. The technique is non-invasive, is capable of recording rider hip rotation asymmetry whilst performing a range of movements unhindered and was found to be efficient and practical, with potential to further advance the analysis of horse and rider interactions

    A bi-articular model for scapular-humeral rhythm reconstruction through data from wearable sensors

    Get PDF
    Patient-specific performance assessment of arm movements in daily life activities is fundamental for neurological rehabilitation therapy. In most applications, the shoulder movement is simplified through a socket-ball joint, neglecting the movement of the scapular-thoracic complex. This may lead to significant errors. We propose an innovative bi-articular model of the human shoulder for estimating the position of the hand in relation to the sternum. The model takes into account both the scapular-toracic and gleno-humeral movements and their ratio governed by the scapular-humeral rhythm, fusing the information of inertial and textile-based strain sensors

    Accuracy and repeatability of wrist joint angles in boxing using an electromagnetic tracking system

    Get PDF
    © 2019, The Author(s). The hand-wrist region is reported as the most common injury site in boxing. Boxers are at risk due to the amount of wrist motions when impacting training equipment or their opponents, yet we know relatively little about these motions. This paper describes a new method for quantifying wrist motion in boxing using an electromagnetic tracking system. Surrogate testing procedure utilising a polyamide hand and forearm shape, and in vivo testing procedure utilising 29 elite boxers, were used to assess the accuracy and repeatability of the system. 2D kinematic analysis was used to calculate wrist angles using photogrammetry, whilst the data from the electromagnetic tracking system was processed with visual 3D software. The electromagnetic tracking system agreed with the video-based system (paired t tests) in both the surrogate ( 0.9). In the punch testing, for both repeated jab and hook shots, the electromagnetic tracking system showed good reliability (ICCs > 0.8) and substantial reliability (ICCs > 0.6) for flexion–extension and radial-ulnar deviation angles, respectively. The results indicate that wrist kinematics during punching activities can be measured using an electromagnetic tracking system

    Estimating Dynamic Gait Stability Using Data from Non-aligned Inertial Sensors

    Get PDF
    Recently, two methods for quantifying the stability of a dynamical system have been applied to human locomotion: local stability (quantified by finite time maximum Lyapunov exponents, λs and λL) and orbital stability (quantified by maximum Floquet multipliers, MaxFm). In most studies published to date, data from optoelectronic measurement systems were used to calculate these measures. However, using wireless inertial sensors may be more practical as they are easier to use, also in ambulatory applications. While inertial sensors have been employed in some studies, it is unknown whether they lead to similar stability estimates as obtained with optoelectronic measurement systems. In the present study, we compared stability measures of human walking estimated from an optoelectronic measurement system with those calculated from an inertial sensor measurement system. Subjects walked on a treadmill at three different speeds while kinematics were recorded using both measurement systems. From the angular velocities and linear accelerations, λs, λL, and MaxFm were calculated. Both measurement systems showed the same effects of walking speed for all variables. Estimates from both measurement systems correlated high for λs and λL, (R > 0.85) but less strongly for MaxFm (R = 0.66). These results indicate that inertial sensors constitute a valid alternative for an optoelectronic measurement system when assessing dynamic stability in human locomotion, and may thus be used instead, which paves the way to studying gait stability during natural, everyday walking

    Teager–Kaiser energy operator signal conditioning improves EMG onset detection

    Get PDF
    Accurate identification of the onset of muscle activity is an important element in the biomechanical analysis of human movement. The purpose of this study was to determine if inclusion of the Teager–Kaiser energy operator (TKEO) in signal conditioning would increase the accuracy of popular electromyography (EMG) onset detection methods. Three methods, visual determination, threshold-based method, and approximated generalized likelihood ratio were used to estimate the onset of EMG burst with and without TKEO conditioning. Reference signals, with known onset times, were constructed from EMG signals collected during isometric contraction of the vastus lateralis (n = 17). Additionally, vastus lateralis EMG signals (n = 255) recorded during gait were used to evaluate a clinical application of the TKEO conditioning. Inclusion of TKEO in signal conditioning significantly reduced mean detection error of all three methods compared with signal conditioning without TKEO, using artificially generated reference data (13 vs. 98 ms, p < 0.001) and also compared with experimental data collected during gait (55 vs. 124 ms, p < 0.001). In conclusion, addition of TKEO as a step in conditioning surface EMG signals increases the detection accuracy of EMG burst boundaries

    Motion Capture: From Radio Signals to Inertial Signals

    Full text link
    The study of the motion of individuals allows to gather relevant information on a person status, to be used in several fields (e.g., medical, sport, and entertainment). Over the past decade, the research activity in motion capture has benefited from the progress of portable and mobile sensors, paving the way toward the use of motion capture techniques in mHealth applications (e.g., remote monitoring of patients, and telerehabilitation). Indeed, even if the optical motion capture, which typically relies on a set of fixed cameras and body-worn reflecting markers, is generally perceived as the standard reference approach, other motion capture techniques, such as radio and inertial, are attracting an increasing attention because of their suitability in remote mHealth applications. Moreover, several hybrid approaches have been studied and proposed in order to overcome the limitations of component technologies considered independently. In this chapter, we present an overview of possible integration strategies between radio and inertial motion capture techniques. We start by investigating a radio-based approach, based on the fingerprinting radio localization technique. Then, the previous approach is improved by integrating inertial measurements: namely, accelerometers are used to provide an estimate of the nodes’ pitches. Finally, the radio signals are abandoned in favor of only inertial measurements (obtained through accelerometers, gyroscopes, and magnetometers). The advantages and limitations of all approaches are discussed in a comparative way, characterizing the similarities and differences between the various approaches

    Towards inertial aided body segment position estimation

    No full text