464 research outputs found
Recommended from our members
Feasibility study and design concept for an orbiting ice-penetrating radar sounder to characterize in three-dimensions the Europan ice mantle down to (and including) any ice/ocean interface
This report presents a radar sounding model based on the range of current working hypotheses for the nature of Europa's icy shell.Institute for Geophysic
Decoupling of the S=1/2 antiferromagnetic zig-zag ladder with anisotropy
The spin-1/2 antiferromagnetic zig-zag ladder is studied by exact
diagonalization of small systems in the regime of weak inter-chain coupling. A
gapless phase with quasi long-range spiral correlations has been predicted to
occur in this regime if easy-plane (XY) anisotropy is present. We find in
general that the finite zig-zag ladder shows three phases: a gapless collinear
phase, a dimer phase and a spiral phase. We study the level crossings of the
spectrum,the dimer correlation function, the structure factor and the spin
stiffness within these phases, as well as at the transition points. As the
inter-chain coupling decreases we observe a transition in the anisotropic XY
case from a phase with a gap to a gapless phase that is best described by two
decoupled antiferromagnetic chains. The isotropic and the anisotropic XY cases
are found to be qualitatively the same, however, in the regime of weak
inter-chain coupling for the small systems studied here. We attribute this to a
finite-size effect in the isotropic zig-zag case that results from
exponentially diverging antiferromagnetic correlations in the weak-coupling
limit.Comment: to appear in Physical Review
Mathematical modeling and forecasting of COVID-19: experience in Santiago de Cuba province
In the province of Santiago de Cuba, Cuba, the COVID-19 epidemic has a limited progression that shows an early small-number peak of infections. Most published mathematical models fit data with high numbers of confirmed cases. In contrast, small numbers of cases make it difficult to predict the course of the epidemic. We present two known models adapted to capture the noisy dynamics of COVID-19 in the Santiago de Cuba province. Parameters of both models were estimated using the approximate-Bayesian-computation framework with dedicated error laws. One parameter of each model was updated on key dates of travel restrictions. Both models approximately predicted the infection peak and the end of the COVID-19 epidemic in Santiago de Cuba. The first model predicted 57 reported cases and 16 unreported cases. Additionally, it estimated six initially exposed persons. The second model forecasted 51 confirmed cases at the end of the epidemic. In conclusion, an opportune epidemiological investigation, along with the low number of initially exposed individuals, might partly explain the favorable evolution of the COVID-19 epidemic in Santiago de Cuba. With the available data, the simplest model predicted the epidemic evolution with greater precision, and the more complex model helped to explain the epidemic phenomenology
Fusion product losses due to fishbone instabilities in deuterium JET plasmas
During development of a high-performance hybrid scenario for future deuterium–tritium experiments on the Joint European Torus, an increased level of fast ion losses in the MeV energy range was observed during the instability of high-frequency n = 1 fishbones. The fishbones are excited during deuterium neutral beam injection combined with ion cyclotron heating. The frequency range of the fishbones, 10–25 kHz, indicates that they are driven by a resonant interaction with the NBI-produced deuterium beam ions in the energy range ≤120 keV. The fast particle losses in a much higher energy range are measured with a fast ion loss detector, and the data show an expulsion of deuterium plasma fusion products, 1 MeV tritons and 3 MeV protons, during the fishbone bursts. An MHD mode analysis with the MISHKA code combined with the nonlinear wave-particle interaction code HAGIS shows that the loss of toroidal symmetry caused by the n = 1 fishbones affects strongly the confinement of non-resonant high energy fusion-born tritons and protons by perturbing their orbits and expelling them. This modelling is in a good agreement with the experimental data.This work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014-2018 under grant agreement No 633053 and from the RCUK Energy Programme [grant No EP/P012450/1]. To obtain further information on the data and models underlying this paper please contact [email protected] . The views and opinions expressed herein do not necessarily reflect those of the European CommissionPeer ReviewedPostprint (author's final draft
Preparation and characterization of starch-poly-epsilon-caprolactone microparticles incorporating bioactive agents for drug delivery and tissue engineering applications
One limitation associated with the delivery of bioactive agents concerns the short half-life of these molecules when administered intravenously,
which results in their loss from the desired site. Incorporation of bioactive agents into depot vehicles provides a means to
increase their persistence at the disease site. Major issues are involved in the development of a proper carrier system able to deliver
the correct drug, at the desired dose, place and time. In this work, starch-poly-e-caprolactone (SPCL) microparticles were developed
for use in drug delivery and tissue engineering (TE) applications. SPCL microparticles were prepared by using an emulsion solvent
extraction/evaporation technique, which was demonstrated to be a successful procedure to obtain particles with a spherical shape (particle
size between 5 and 900 lm) and exhibiting different surface morphologies. Their chemical structure was confirmed by Fourier transform
infrared spectroscopy. To evaluate the potential of the developed microparticles as a drug delivery system, dexamethasone (DEX)
was used as model drug. DEX, a well-known component of osteogenic differentiation media, was entrapped into SPCL microparticles at
different percentages up to 93%. The encapsulation efficiency was found to be dependent on the polymer concentration and drug-to-polymer
ratio. The initial DEX release seems to be governed mainly by diffusion, and it is expected that the remaining DEX will be released
when the polymeric matrix starts to degrade. In this work it was demonstrated that SPCL microparticles containing DEX can be successfully
prepared and that these microparticular systems seem to be quite promising for controlled release applications, namely as carriers
of important differentiation agents in TE.E.R.B. thanks the Marie Curie Host Fellowships for Early Stage Research Training (EST) "Alea Jacta EST" (MEST-CT-2004-008104) for providing her with a PhD Fellowship. This work was partially supported by the European NoE EXPERTISSUES (NMP3-CT-2004-500283)
The Role of Current and Historical Alcohol Use in Hepatic Fibrosis Among HIV-Infected Individuals
We examined risk factors for advanced hepatic fibrosis [fibrosis-4 (FIB)-4 >3.25] including both current alcohol use and a diagnosis of alcohol use disorder among HIV-infected patients. Of the 12,849 patients in our study, 2133 (17%) reported current hazardous drinking by AUDIT-C, 2321 (18%) had a diagnosis of alcohol use disorder, 2376 (18%) were co-infected with chronic hepatitis C virus (HCV); 596 (5%) had high FIB-4 scores >3.25 as did 364 (15%) of HIV/HCV coinfected patients. In multivariable analysis, HCV (adjusted odds ratio (aOR) 6.3, 95% confidence interval (CI) 5.2–7.5), chronic hepatitis B (aOR 2.0, 95% CI 1.5–2.8), diabetes (aOR 2.3, 95% CI 1.8–2.9), current CD4 <200 cells/mm3 (aOR 5.4, 95% CI 4.2–6.9) and HIV RNA >500 copies/mL (aOR 1.3, 95% CI 1.0–1.6) were significantly associated with advanced fibrosis. A diagnosis of an alcohol use disorder (aOR 1.9, 95% CI 1.6–2.3) rather than report of current hazardous alcohol use was associated with high FIB-4. However, among HIV/HCV coinfected patients, both current hazardous drinkers (aOR 1.6, 95% CI 1.1–2.4) and current non-drinkers (aOR 1.6, 95% CI 1.2–2.0) were more likely than non-hazardous drinkers to have high FIB-4, with the latter potentially reflecting the impact of sick abstainers. These findings highlight the importance of using a longitudinal measure of alcohol exposure when evaluating the impact of alcohol on liver disease and associated outcomes
Baikal-GVD
We present the status of the Gigaton Volume Detector in Lake Baikal (Baikal-GVD) designed for the detection of high energy neutrinos of astrophysical origin. The telescope consists of functionally independent clusters, sub-arrays of optical modules (OMs), which are connected to shore by individual electro-optical cables. During 2015 the GVD demonstration cluster, comprising 192 OMs, has been successfully operated in Lake Baikal. In 2016 this array was upgraded to baseline configuration of GVD cluster with 288 OMs arranged on eight vertical strings. Thus the instrumented water volume has been increased up to about 5.9 Mtons. The array was commissioned in early April 2016 and takes data since then. We describe the configuration and design of the 2016 array. Preliminary results obtained with data recorded in 2015 are also discussed
Multifunctional Magnetic-fluorescent Nanocomposites for Biomedical Applications
Nanotechnology is a fast-growing area, involving the fabrication and use of nano-sized materials and devices. Various nanocomposite materials play a number of important roles in modern science and technology. Magnetic and fluorescent inorganic nanoparticles are of particular importance due to their broad range of potential applications. It is expected that the combination of magnetic and fluorescent properties in one nanocomposite would enable the engineering of unique multifunctional nanoscale devices, which could be manipulated using external magnetic fields. The aim of this review is to present an overview of bimodal “two-in-one” magnetic-fluorescent nanocomposite materials which combine both magnetic and fluorescent properties in one entity, in particular those with potential applications in biotechnology and nanomedicine. There is a great necessity for the development of these multifunctional nanocomposites, but there are some difficulties and challenges to overcome in their fabrication such as quenching of the fluorescent entity by the magnetic core. Fluorescent-magnetic nanocomposites include a variety of materials including silica-based, dye-functionalised magnetic nanoparticles and quantum dots-magnetic nanoparticle composites. The classification and main synthesis strategies, along with approaches for the fabrication of fluorescent-magnetic nanocomposites, are considered. The current and potential biomedical uses, including biological imaging, cell tracking, magnetic bioseparation, nanomedicine and bio- and chemo-sensoring, of magnetic-fluorescent nanocomposites are also discussed
- …