19 research outputs found

    A BP Neural Network Based Technique for HIF Detection and Location on Distribution Systems With Distributed Generation

    Get PDF
    Abstract. High Impedance Faults (HIF) are faults of difficult detection and location while using traditional digital relaying. In this article it is presented a new proposal for detection and location of HIF's in distribution systems with distributed generation (DG), based on artificial neural networks. The methodology inputs are the local measured voltage and current phase components, supplying as output the detection, classification and location of the fault, when it occurs. The basic characteristics, the algorithm and comparative tests with other detection and location methodologies are presented in this article. The proposed scheme was tested in a simulation platform of a distribution system with DG. The comparative results of the technique with usual fault detection and location schemes show the high efficiency and robustness of the method

    A new approach to the analysis of stability for small disturbances in distribution systems of electric power distributed synchronous generators

    No full text
    Nesta tese de doutorado, a estabilidade a pequenas perturbações é estudada sob a ótica dos sistemas de distribuição de energia elétrica com geradores síncronos distribuídos. Duas peculiaridades específicas destes sistemas são abordadas: o desequilíbrio da carga e da rede e a proximidade das cargas aos geradores. Em relação ao primeiro tópico, duas abor dagens são propostas para o estudo de estabilidade a pequenas perturbações em sistemas com desequilíbrio da carga, uma delas baseada na estimação modal a partir de dados obtidos através de medições ou simulações no domínio do tempo, e a outra baseada na modelagem fasorial do sistema com desequilíbrio da carga e posterior linearização do sistema algébrico-diferencial não-linear obtido. Em relação ao segundo tópico, constatam-se nesta tese que as oscilações eletromecânicas podem induzir certos fenômenos de qualidade de energia, notadamente as flutuações de tensão. Nesta tese, uma estrutura é proposta e critérios são definidos para o estudo destas flutuações induzidas por problemas tipicamente relacionados à estabilidade, considerando o estudo de perturbações isoladas e também o estudo estatístico de perturbações. Através desta análise, é proposto também um procedimento de projeto de controladores de amortecimento com critérios bem definidos para auxiliar na mitigação destas flutuações de tensão induzidas por oscilações eletromecânicas. Tal procedimento de projeto é complementar aos índices de desempenho do sistema dinâmico tipicamente utilizados para o projeto destes controladores em sistemas de transmissão. Os significativos avanços em ambos os tópicos abordados abriram um vasto campo de trabalho a ser estudado do ponto de vista da estabilidade a pequenas perturbações de sistemas de distribuição com geradores síncronos distribuídos.In this thesis, the small-signal stability is studied from the perspective of power distribution systems with distributed synchronous generators. Two specific peculiarities of these systems are addressed: the load and network unbalance, and the proximity of loads to generators. Regarding the first topic, two approaches are proposed to the small-signal stability study of power systems with load unbalance, one based on modal estimation through data obtained from measurements or time-domain simulations, and another one based on a phasorial model of the system with load unbalance and later linearization of the differential-algebraic nonlinear system obtained. Regarding to the second topic, it is observed in this thesis that electromechanical oscillations can induce certain power quality phenomena, notably voltage fluctuations. In this thesis, a structure is proposed and criteria are defined to the study of these fluctuations induced by typical stability problems, considering the study of isolated perturbations and also the statistical study of perturbations. Through this analysis, a procedure for the design of power system stabilizers with clearly defined criteria is also proposed to assist in mitigating the voltage fluctuations induced by electromechanical oscillations. This design procedure is complementary to the stability criteria currently used in the design of power system stabilizers for power transmission systems. The significant advances in both studied topics have also opened a large research field related to the small-signal stability of power distribution systems with distributed synchronous generators

    Novos desenvolvimentos na localização de faltas em sistemas de distribuição de energia elétrica fundamentada na impedância

    Get PDF
    Apesar do crescente desenvolvimento das metodologias de localização de faltas fundamentadas na impedância para sistemas de distribuição de energia elétrica nas últimas décadas, alguns aspectos ainda carecem de progressos, especialmente frente à crescente necessidade de aumento da qualidade da energia elétrica entregue aos consumidores. Um destes aspectos diz respeito à consideração da capacitância das linhas de distribuição, efeito nunca dantes considerado para este fim pelas metodologias baseadas em impedância aparente. Assim sendo, o presente trabalho apresenta novos desenvolvimentos relativos à consideração do efeito capacitivo para as metodologias de localização de faltas fundamentadas na impedância para sistemas de distribuição de energia elétrica. O principal desenvolvimento apresentado é um novo equacionamento para fins de localização de faltas, que torna necessária a apresentação de outro desenvolvimento, o de um algoritmo de localização de faltas que considere a capacitância da linha. As novas equações são apresentadas para todos os tipos de faltas e constituem-se de equações polinomiais de segunda ordem em relação ao local da falta. De forma a entender a resposta destas equações frente a diferentes casos de faltas e determinar qual a solução fisicamente correta destas equações, as mesmas são analisadas sob três pontos de vista, a saber, matemático, físico, e numérico. Inicialmente estas equações são analisadas de forma analítica considerandose faltas em um mesmo local, mas com resistências diferentes. Posteriormente a mesma análise é realizada numericamente através de simulações computacionais. Os desenvolvimentos propostos são também submetidos a testes de faltas, simuladas computacionalmente em um sistema sem laterais ou cargas intermediárias. Os resultados obtidos são comparados frente a resultados obtidos também para outras metodologias que constituem atualmente o estado da arte em localização de faltas fundamentada na impedância para sistemas de distribuição de energia elétrica. Através destes resultados é possível mostrar a grande influência que o efeito capacitivo possui nestas metodologias, mesmo em sistemas aéreos de distribuição, e elucidar as grandes melhorias obtidas através dos desenvolvimentos propostos.Despite the increasing development of impedance-based fault location techniques for electric power distribution systems in the last decades, some aspects still require to progress, especially with the increasing necessity of power quality enhancement. One of these aspects regards to the distribution line shunt admittance consideration, effect that has never been considered before by the impedance-based fault location methods for power distribution systems. In this way, this work presents further improvements regarding the capacitive effect consideration for impedance-based fault location methods for power distribution systems. The main improvement presented is the development of new fault location equations, which yield the necessity of another improvement, a modified fault location algorithm that also considers the line shunt admittance. The new equations are presented for all fault types and are constituted by second-order polynomials in relation to the fault location. In order to understand the response from these equations regarding different fault situations and determine which solution is the physically feasible one, these equations are analyzed from three different points of view, i.e., mathematical, physical, and numerical. First, the developed equations are analytically analyzed considering faults in one location with different fault resistances. After, the same analysis is numerically carried out through computational simulations. The performance of the proposed improvements are also evaluated through computational simulations of faults in a power distribution system without laterals or intermediate loads. The obtained results are compared with results from the current state-of-the-art impedance-based fault location methodologies for power distribution systems. Through these results it is possible to show the great effect that the line shunt admittance, even in aerial distribution systems, has on the existing fault location methodologies and also the great improvements brought by the proposed developments

    Novos desenvolvimentos na localização de faltas em sistemas de distribuição de energia elétrica fundamentada na impedância

    Get PDF
    Apesar do crescente desenvolvimento das metodologias de localização de faltas fundamentadas na impedância para sistemas de distribuição de energia elétrica nas últimas décadas, alguns aspectos ainda carecem de progressos, especialmente frente à crescente necessidade de aumento da qualidade da energia elétrica entregue aos consumidores. Um destes aspectos diz respeito à consideração da capacitância das linhas de distribuição, efeito nunca dantes considerado para este fim pelas metodologias baseadas em impedância aparente. Assim sendo, o presente trabalho apresenta novos desenvolvimentos relativos à consideração do efeito capacitivo para as metodologias de localização de faltas fundamentadas na impedância para sistemas de distribuição de energia elétrica. O principal desenvolvimento apresentado é um novo equacionamento para fins de localização de faltas, que torna necessária a apresentação de outro desenvolvimento, o de um algoritmo de localização de faltas que considere a capacitância da linha. As novas equações são apresentadas para todos os tipos de faltas e constituem-se de equações polinomiais de segunda ordem em relação ao local da falta. De forma a entender a resposta destas equações frente a diferentes casos de faltas e determinar qual a solução fisicamente correta destas equações, as mesmas são analisadas sob três pontos de vista, a saber, matemático, físico, e numérico. Inicialmente estas equações são analisadas de forma analítica considerandose faltas em um mesmo local, mas com resistências diferentes. Posteriormente a mesma análise é realizada numericamente através de simulações computacionais. Os desenvolvimentos propostos são também submetidos a testes de faltas, simuladas computacionalmente em um sistema sem laterais ou cargas intermediárias. Os resultados obtidos são comparados frente a resultados obtidos também para outras metodologias que constituem atualmente o estado da arte em localização de faltas fundamentada na impedância para sistemas de distribuição de energia elétrica. Através destes resultados é possível mostrar a grande influência que o efeito capacitivo possui nestas metodologias, mesmo em sistemas aéreos de distribuição, e elucidar as grandes melhorias obtidas através dos desenvolvimentos propostos.Despite the increasing development of impedance-based fault location techniques for electric power distribution systems in the last decades, some aspects still require to progress, especially with the increasing necessity of power quality enhancement. One of these aspects regards to the distribution line shunt admittance consideration, effect that has never been considered before by the impedance-based fault location methods for power distribution systems. In this way, this work presents further improvements regarding the capacitive effect consideration for impedance-based fault location methods for power distribution systems. The main improvement presented is the development of new fault location equations, which yield the necessity of another improvement, a modified fault location algorithm that also considers the line shunt admittance. The new equations are presented for all fault types and are constituted by second-order polynomials in relation to the fault location. In order to understand the response from these equations regarding different fault situations and determine which solution is the physically feasible one, these equations are analyzed from three different points of view, i.e., mathematical, physical, and numerical. First, the developed equations are analytically analyzed considering faults in one location with different fault resistances. After, the same analysis is numerically carried out through computational simulations. The performance of the proposed improvements are also evaluated through computational simulations of faults in a power distribution system without laterals or intermediate loads. The obtained results are compared with results from the current state-of-the-art impedance-based fault location methodologies for power distribution systems. Through these results it is possible to show the great effect that the line shunt admittance, even in aerial distribution systems, has on the existing fault location methodologies and also the great improvements brought by the proposed developments
    corecore