2,808 research outputs found

    Radiative transfer in cylindrical threads with incident radiation. VII. Multi-thread models

    Get PDF
    Aims. Our aim is to improve on previous radiative transfer calculations in illuminated cylindrical threads in order to better understand the physical conditions in cool solar chromospheric and coronal structures commonly observed in hydrogen and helium lines. Methods. We solve the radiative transfer and statistical equilibrium equations in a two-dimensional cross-section of a cylindrical structure oriented horizontally and lying above the solar surface. The cylinder is filled with a mixture of hydrogen and helium, and is illuminated at a given altitude from the solar disc. We construct simple models made from a single thread, or from an ensemble of several threads along the line of sight. This first use of 2D multi-thread fine structure modelling combining hydrogen and helium radiative transfer allows us to compute synthetic emergent spectra from cylindrical structures and to study the effect of line-of-sight integration of an ensemble of threads under a range of physical conditions. We analyse the effects of variations in temperature distribution and in gas pressure.We consider the effect of multi-thread structures within a given field of view and the effect of peculiar velocities between the structures in a multi-thread model. These new models are compared to the single thread model, and tested with varying parameters. Results. The presence of a temperature gradient, with temperature increasing towards the edge of the cylindrical thread, reduces the relative importance of the incident radiation coming from the solar disc on the emergent intensities of most hydrogen and helium lines. We also find that when assuming randomly displaced threads in a given field of view, the integrated intensities of optically thick and thin transitions behave considerably differently. In optically thin lines, the emergent intensity increases proportionally with the number of threads, and the spatial variation of the intensity becomes increasingly homogeneous. Optically thick lines however saturate after only a few threads. As a consequence, the spatial variation of the intensity retains much similarity with that of the first few threads. The multi-thread model produces complex line profiles with significant asymmetries if randomly generated line-of-sight velocities are added for each thread. Conclusions. These new computations show for the first time the effect of integrating the radiation emitted in H and He lines by several cylindrical threads static or moving along the line of sight. They can be used to interpret high-spatial and spectral resolutions of cylindrical structures found in the solar atmosphere, such as cool coronal loops or prominence threads

    Solar prominence modelling and plasma diagnostics at ALMA wavelengths

    Get PDF
    Our aim is to test potential solar prominence plasma diagnostics as obtained with the new solar capability of the Atacama Large Millimeter / submillimeter Array (ALMA). We investigate the thermal and plasma diagnostic potential of ALMA for solar prominences through the computation of brightness temperatures at ALMA wavelengths. The brightness temperature, for a chosen line of sight, is calculated using densities of hydrogen and helium obtained from a radiative transfer code under non local thermodynamic equilibrium (NLTE) conditions, as well as the input internal parameters of the prominence model in consideration. Two distinct sets of prominence models were used: isothermal-isobaric fine-structure threads, and large-scale structures with radially increasing temperature distributions representing the prominence-to-corona transition region. We compute brightness temperatures over the range of wavelengths in which ALMA is capable of observing (0.32 - 9.6mm), however we particularly focus on the bands available to solar observers in ALMA cycles 4 and 5, namely 2.6 - 3.6mm (Band 3) and 1.1 - 1.4mm (Band 6). We show how the computed brightness temperatures and optical thicknesses in our models vary with the plasma parameters (temperature and pressure) and the wavelength of observation. We then study how ALMA observables such as the ratio of brightness temperatures at two frequencies can be used to estimate the optical thickness and the emission measure for isothermal and non-isothermal prominences. From this study we conclude that, for both sets of models, ALMA presents a strong thermal diagnostic capability, provided that the interpretation of observations is supported by the use of non-LTE simulation results.Comment: Submitted to Solar Physic

    Pretreatment with beta-blockers and the frequency of hypokalemia in patients with acute chest pain

    Get PDF
    Plasma potassium concentration was measured at admission in 1234 patients who presented with acute chest pain. One hundred and ninety five patients were on P blockers before admission. The potassium concentrations of patients admitted early (within four hours of onsetof symptoms) were compared with those admitted later (4-18 hours after onset of symptoms). There was a transient fall in plasma potassium concentrations in patients not pre-treated with , B blockers. This was not seen in patients who had been on P blockers before admission. Nonselective, B blockers were more effective than cardioselective agents in maintaining concentrationsof plasma potassium. These findings suggest a mechanism for the beneficial effects of ,B blockers on morbidity and mortality in acute myocardial infarction

    Floating-disk parylene microvalve for self-regulating biomedical flow controls

    Get PDF
    A novel self-regulating parylene micro valve is presented in this paper with potential applications for biomedical flow controls. Featuring a free-floating bendable valve disk and two-level valve seat, this surface-micromachined polymeric valve accomplishes miniature pressure/flow rate regulation in a band-pass profile stand-alone without the need of power sources or active actuation. Experimental data of underwater testing results have successfully demonstrated that the microfabricated in-channel valve can regulate water flow at 0-80 mmHg and 0-10 µL/min pressure/flow rate level, which is perfectly suitable for biomedical and lab-on-a-chip applications. For example, such biocompatible microvalve can be incorporated in ocular implants for control of eye fluid drainage to fulfill intraocular pressure (IOP) regulation in glaucoma patients

    Making postgraduate students and supervisors aware of the role of emotions in the PhD process

    Get PDF
    Emotions are an integral part of the PhD process. A range of emotions are common and to be expected. How do emotions affect the PhD process for both postgraduate students and their supervisors? How can we make our emotions work positively for us in the PhD process? To explore answers to these questions, three lecturers currently supervising postgraduates and three postgraduates at various stages in their doctoral studies collectively pooled their experiences. We developed an interactive workshop that was recently conducted for postgraduate students at Murdoch University and at the Australian Association for Social Research annual conference 2002. This presentation will explore the role that emotions play in the PhD process and how supervisors and postgraduates alike can benefit from reflecting on this issue. A number of practical (and humorous) tips will be provided as well as examples from others' PhD experiences. The role of emotions at the beginning, middle and end of a PhD program will be explored. The data collection and analysis phases are a time when emotions may run riot. Trepidation is especially common when fieldwork or data collection is involved, as is anger when postgraduate's views about how the world works are challenged and then sadness (and relief!) when the data collection phase is finished. We will discuss how supervisors can assist their postgraduates to make these feelings work for them. The presentation will also explore the emotions that arise from the supervisor-postgraduate partnership

    On determining the noon polar cap boundary from SuperDARN HF radar backscatter characteristics

    No full text
    International audiencePrevious work has shown that ionospheric HF radar backscatter in the noon sector can be used to locate the footprint of the magnetospheric cusp particle precipitation. This has enabled the radar data to be used as a proxy for the location of the polar cap boundary, and hence measure the flow of plasma across it to derive the reconnection electric field in the ionosphere. This work used only single radar data sets with a field of view limited to ~2 h of local time. In this case study using four of the SuperDARN radars, we examine the boundary determined over 6 h of magnetic local time around the noon sector and its relationship to the convection pattern. The variation with longitude of the latitude of the radar scatter with cusp characteristics shows a bay-like feature. It is shown that this feature is shaped by the variation with longitude of the poleward flow component of the ionospheric plasma and may be understood in terms of cusp ion time-of-flight effects. Using this interpretation, we derive the time-of-flight of the cusp ions and find that it is consistent with approximately 1 keV ions injected from a subsolar reconnection site. A method for deriving a more accurate estimate of the location of the open-closed field line boundary from HF radar data is described.Key words: Ionosphere (ionosphere?magnetosphere interactions; plasma convection) · Magnetospheric physics (magnetopause · cusp · and boundary layers

    Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors

    Get PDF
    This paper presents an implantable parylene-based wireless pressure sensor for biomedical pressure sensing applications specifically designed for continuous intraocular pressure (IOP) monitoring in glaucoma patients. It has an electrical LC tank resonant circuit formed by an integrated capacitor and an inductor coil to facilitate passive wireless sensing using an external interrogating coil connected to a readout unit. Two surface-micromachined sensor designs incorporating variable capacitor and variable capacitor/inductor resonant circuits have been implemented to realize the pressure-sensitive components. The sensor is monolithically microfabricated by exploiting parylene as a biocompatible structural material in a suitable form factor for minimally invasive intraocular implantation. Pressure responses of the microsensor have been characterized to demonstrate its high pressure sensitivity (> 7000 ppm/mmHg) in both sensor designs, which confirms the feasibility of pressure sensing with smaller than 1 mmHg of resolution for practical biomedical applications. A six-month animal study verifies the in vivo bioefficacy and biostability of the implant in the intraocular environment with no surgical or postoperative complications. Preliminary ex vivo experimental results verify the IOP sensing feasibility of such device. This sensor will ultimately be implanted at the pars plana or on the iris of the eye to fulfill continuous, convenient, direct, and faithful IOP monitoring

    Implantable parylene-based wireless intraocular pressure sensor

    Get PDF
    This paper presents a novel implantable, wireless, passive pressure sensor for ophthalmic applications. Two sensor designs incorporating surface-micromachined variable capacitor and variable capacitor/inductor are implemented to realize the pressure sensitive components. The sensor is monolithically microfabricated using parylene as a biocompatible structural material in a suitable form factor for increased ease of intraocular implantation. Pressure responses of the microsensor are characterized on-chip to demonstrate its high pressure sensitivity (> 7000 ppm/mmHg) with mmHg level resolution. An in vivo animal study verifies the biostability of the sensor implant in the intraocular environment after more than 150 days. This sensor will ultimately be implanted at the pars plana or iris of the eye to fulfill continuous intraocular pressure (IOP) monitoring in glaucoma patients

    Implantable Unpowered Parylene MEMS Intraocular Pressure Sensor

    Get PDF
    This paper presents the first implantable, unpowered, parylene-based micro-electro-mechanical-systems (MEMS) pressure sensor for intraocular pressure (IOP) sensing. From in situ mechanical deformation of the compliant structures, this sensor registers pressure variations without power consumption/transduction. Micromachined high-aspect-ratio thin-walled tubes in different geometric layouts are exploited to obtain a high-sensitivity pressure response. An integrated packaging method has been successfully developed to realize suture-less implantation of the device. In vitro testing results have demonstrated that the IOP sensor can achieve 0.67 degree/mmHg angular sensitivity with a spiral-tube design, 3.43 µm/mmHg lateral sensitivity with a long-armed-tube design, and 0.38 µm/mmHg longitudinal sensitivity with a serpentine-tube design. This IOP sensor is designed to be implanted in the anterior chamber of the eye and anchored directly on the iris so that, under incident visible light, the pressure response of the implant can be directly observed from outside the eye, which enables faithful and unpowered IOP monitoring in glaucoma patient

    Wafer-Level Parylene Packaging With Integrated RF Electronics for Wireless Retinal Prostheses

    Get PDF
    This paper presents an embedded chip integration technology that incorporates silicon housings and flexible Parylene-based microelectromechanical systems (MEMS) devices. Accelerated-lifetime soak testing is performed in saline at elevated temperatures to study the packaging performance of Parylene C thin films. Experimental results show that the silicon chip under test is well protected by Parylene, and the lifetime of Parylenecoated metal at body temperature (37°C) is more than 60 years, indicating that Parylene C is an excellent structural and packaging material for biomedical applications. To demonstrate the proposed packaging technology, a flexible MEMS radio-frequency (RF) coil has been integrated with an RF identification (RFID) circuit die. The coil has an inductance of 16 μH with two layers of metal completely encapsulated in Parylene C, which is microfabricated using a Parylene–metal–Parylene thin-film technology. The chip is a commercially available read-only RFID chip with a typical operating frequency of 125 kHz. The functionality of the embedded chip has been tested using an RFID reader module in both air and saline, demonstrating successful power and data transmission through the MEMS coil
    corecore