6 research outputs found

    An unusual electrical burn caused by alkaline batteries

    No full text
    Electrical burns caused by low-voltage batteries are rarely reported. We recently encountered a male patient who suffered from a superficial second-degree burn over his left elbow and back. The total body surface area of the burn was estimated to be 6%. After interviewing the patient, the cause was suspected to be related to the explosion of a music player on the left-side of his waist, carried on his belt while he was painting a bathroom wall. Elevated creatine kinase levels and hematuria indicated rhabdomyolysis and suggested an electrical burn. Initial treatment was done in the burn intensive care unit with fluid challenge and wound care. The creatine kinase level decreased gradually and the hematuria was gone after 4 days in the intensive care unit. He was then transferred to the general ward for further wound management and discharged from our burn center after a total of 11 days without surgical intervention. Copyright (C) 2012, Elsevier Taiwan LLC & Formosan Medical Association. All rights reserved

    A modified free chimeric osteocutaneous fibular flap design for head and neck reconstruction: Experience on a series of 10 cases

    No full text
    Background We have previously described a modified chimeric fibular osteocutaneous flap design based on a combination of a traditional fibular flap and a peroneal artery perforator fasciocutaneous flap for mandible and adjacent soft tissue reconstruction. The purpose of this article is to share our experience with a larger case series utilizing this new technique for mandible and adjacent soft tissue reconstruction after cancer wide excision surgery and a more detailed description on these flaps harvesting procedures. Patients and methods Ten patients (age range from 32 to 63 years), who had segmental defect of mandible and adjacent soft tissue defect after cancer wide excision surgery, received mandible and adjacent soft tissue reconstruction based on the modified chimeric fibular flap design. Results The skin paddle based on peroneal perforators ranged from 9 cm x 3.5 cm to 10 cm x 10 cm and the mean pedicle length was 8.9 cm. Four patients underwent primary closure of the donor site. Three flap salvage procedures were performed due to vascular thrombosis and all flaps survived well. Nine patients had acceptable outer appearance, and one patient complained of cheek sunken. All patients had at least 3-cm interincisor distance during a mean of 12-month follow-up period. Conclusion The modified chimeric osteocutaneous fibula flaps were feasible design with few intermuscular septum problems during bone fixation. Furthermore, it provided larger skin paddles with few restrictions to reconstruct the cheek skin defect. (c) 2013 Wiley Periodicals, Inc

    An unusual electrical burn caused by alkaline batteries

    Get PDF
    Electrical burns caused by low-voltage batteries are rarely reported. We recently encountered a male patient who suffered from a superficial second-degree burn over his left elbow and back. The total body surface area of the burn was estimated to be 6%. After interviewing the patient, the cause was suspected to be related to the explosion of a music player on the left-side of his waist, carried on his belt while he was painting a bathroom wall. Elevated creatine kinase levels and hematuria indicated rhabdomyolysis and suggested an electrical burn. Initial treatment was done in the burn intensive care unit with fluid challenge and wound care. The creatine kinase level decreased gradually and the hematuria was gone after 4 days in the intensive care unit. He was then transferred to the general ward for further wound management and discharged from our burn center after a total of 11 days without surgical intervention

    Is artificial dermis an effective tool in the treatment of tendon-exposed wounds?

    No full text
    As flap surgery remains the main technique to close wounds with tendon exposure, the application of artificial dermis in these complex soft tissue wounds is seldom reported. The purpose of this article is to review our experiences in the treatment of tendon-exposed wounds with artificial dermis. This retrospective study included 23 patients with 33 tendon-exposed wounds treated with artificial dermis from 2004 to 2009. Data including patient demographics, wound type, duration from artificial dermis implantation to split thickness skin grafting, surgical complications, and clinical outcome were obtained by chart review. Successful treatment was defined as the formation of golden-yellow neodermis followed by successful split thickness skin grafting. Among the 33 tendon-exposed wounds, 11 were secondary to chronic ulcers, 16 to acute wounds, and 6 to surgical wounds after hypertrophic scar excision. The mean patient age was 49 years. The overall success rate with the artificial dermis technique was 82%, including 63% in the chronic ulcer group, 88% in the acute wounds, and 100% in the surgical wounds. In the success group, 11% of the wounds required repeated artificial dermis implantations. Within the failure group, two wounds were closed by below knee amputation, two by local flap surgery, and two were allowed spontaneous healing as a result of graft failure. We have demonstrated an overall success rate of 82% for tendon-exposed wound closure by using artificial dermis. The outcome was better in surgical and acute wounds than in chronic wounds

    Deep Learning–Assisted Burn Wound Diagnosis: Diagnostic Model Development Study

    No full text
    BackgroundAccurate assessment of the percentage total body surface area (%TBSA) of burn wounds is crucial in the management of burn patients. The resuscitation fluid and nutritional needs of burn patients, their need for intensive unit care, and probability of mortality are all directly related to %TBSA. It is difficult to estimate a burn area of irregular shape by inspection. Many articles have reported discrepancies in estimating %TBSA by different doctors. ObjectiveWe propose a method, based on deep learning, for burn wound detection, segmentation, and calculation of %TBSA on a pixel-to-pixel basis. MethodsA 2-step procedure was used to convert burn wound diagnosis into %TBSA. In the first step, images of burn wounds were collected from medical records and labeled by burn surgeons, and the data set was then input into 2 deep learning architectures, U-Net and Mask R-CNN, each configured with 2 different backbones, to segment the burn wounds. In the second step, we collected and labeled images of hands to create another data set, which was also input into U-Net and Mask R-CNN to segment the hands. The %TBSA of burn wounds was then calculated by comparing the pixels of mask areas on images of the burn wound and hand of the same patient according to the rule of hand, which states that one’s hand accounts for 0.8% of TBSA. ResultsA total of 2591 images of burn wounds were collected and labeled to form the burn wound data set. The data set was randomly split into training, validation, and testing sets in a ratio of 8:1:1. Four hundred images of volar hands were collected and labeled to form the hand data set, which was also split into 3 sets using the same method. For the images of burn wounds, Mask R-CNN with ResNet101 had the best segmentation result with a Dice coefficient (DC) of 0.9496, while U-Net with ResNet101 had a DC of 0.8545. For the hand images, U-Net and Mask R-CNN had similar performance with DC values of 0.9920 and 0.9910, respectively. Lastly, we conducted a test diagnosis in a burn patient. Mask R-CNN with ResNet101 had on average less deviation (0.115% TBSA) from the ground truth than burn surgeons. ConclusionsThis is one of the first studies to diagnose all depths of burn wounds and convert the segmentation results into %TBSA using different deep learning models. We aimed to assist medical staff in estimating burn size more accurately, thereby helping to provide precise care to burn victims

    Tomotherapy as an Alternative Irradiative Treatment for Complicated Keloids

    No full text
    The aim of this study was to investigate the treatment of complicated keloids with helical tomotherapy (HT) and electron beam radiotherapy. From July 2018 to September 2018, 11 patients with 23 keloid lesions treated with HT were enrolled. Additionally, 11 patients with 20 lesions treated with electron beam radiotherapy in the same period were enrolled. Patients in both groups were treated within 24 h after surgical excision of the keloid lesion with 13.5 Gy in three consecutive daily fractions. The median follow-up period was 15 months. The local control rate was 91.3% and 80% in the HT group and the electron beam group, respectively. No acute adverse effects were observed in either group, but most patients exhibited pigmentation. No radiation-induced cancer occurred in these patients up to the time of this report. Pain and pruritus improved for all patients and more obviously for three patients with complicated keloids treated with HT. The measured surface dose was 103.7–112.5% and 92.8–97.6% of the prescribed dose in the HT group and the electron beam group, respectively. HT can be considered an alternative in cases where it is not feasible to use multiple electron fields, due to encouraging clinical outcomes
    corecore