Temperature and load-ratio dependent fatigue-crack growth in the CrMnFeCoNi high-entropy alloy
Multiple-principal element alloys known as high-entropy alloys have rapidly been gaining attention for the vast variety of compositions and potential combinations of properties that remain to be explored. Of these alloys, one of the earliest, the ‘Cantor alloy’ CrMnFeCoNi, displays excellent damage-tolerance with tensile strengths of ∼1 GPa and fracture toughness values in excess of 200 MPa√m; moreover, these mechanical properties tend to further improve at cryogenic temperatures. However, few studies have explored its corresponding fatigue properties. Here we expand on our previous study to examine the mechanics and mechanisms of fatigue-crack propagation in the CrMnFeCoNi alloy (∼7 μm grain size), with emphasis on long-life, near-threshold fatigue behavior, specifically as a function of load ratio at temperatures between ambient and liquid-nitrogen temperatures (293 K–77 K). We find that ΔKth fatigue thresholds are decreased with increasing positive load ratios, R between 0.1 and 0.7, but are increased at decreasing temperature. These effects can be attributed to the role of roughness-induced crack closure, which was estimated using compliance measurements. Evidence of deformation twinning at the crack tip during fatigue-crack advance was not apparent at ambient temperatures but seen at higher stress intensities (ΔK ∼ 20 MPa√m) at 77 K by post mortem microstructural analysis for tests at R = 0.1 and particularly at 0.7. Overall, the fatigue behavior of this alloy was found to be superior, or at least comparable, to conventional cryogenic and TWIP steels such as 304 L or 316 L steels and Fe-Mn steels; these results coupled with the remarkable strength and fracture toughness of the Cantor alloy at low temperatures indicate significant promise for the utility of this material for applications at cryogenic environments
Recommended from our members
On the exceptional damage-tolerance of gradient metallic materials
An experimental study is described on the fracture toughness and micro-mechanisms associated with the initiation and propagation of cracks in metallic nickel containing marked gradients in grain size, ranging from ∼30 nm to ∼4 μm. Specifically, cracks are grown in a gradient structured (GS) nickel with grain-size gradient ranging from the coarse macro-scale to nano-scale (CG → NG) and vice versa (NG → CG), with the measured crack-resistance R-curves compared to the corresponding behavior in uniform nano-grained (NG) and coarse-grained (CG) materials. It is found that the gradient structures display a much-improved combination of high strength and toughness compared to uniform grain-sized materials. However, based on J-integral measurements in the gradient materials, the crack-initiation toughness is far higher for cracks grown in the direction of the coarse-to-nano grained gradient than vice versa, a result which we ascribe primarily to excessive crack-tip blunting in the coarse-grained microstructure. Both gradient structures, however, display marked rising R-curve behavior with exceptional crack-growth toughnesses exceeding 200 MPa.m½
A unified potential drop calibration function for common crack growth specimens
Calibration functions, used to determine crack extension from potential drop measurements, are not readily available for many common crack growth specimen types. This restricts testing to a limited number of specimen types, typically resulting in overly conservative material properties being used in residual life assessments. This paper presents a unified calibration function which can be applied to all common crack growth specimen types, mitigating this problem and avoiding the significant costs associated with the current conservative approach. Using finite element analysis, it has been demonstrated that Johnson’s calibration function can be applied to the seven most common crack growth specimen types: C(T), SEN(T), SEN(B), M(T), DEN(T), CS(T) and DC(T). A parametric study has been used to determine the optimum configuration of electrical current inputs and PD probes. Using the suggested configurations, the error in the measurement of crack extension is <6% for all specimen types, which is relatively small compared to other sources of error commonly associated with the potential drop technique
The influence of microstructure on the fatigue crack growth rate in marine steels in the Paris Region
This paper presents a study on the effect of microstructure on the fatigue crack growth (FCG) rate in advanced S355 marine steels in the Paris Region of the da/dN versus ΔK log–log plot. The environments of study were air and seawater (SW), under constant amplitude sinewave fatigue loading. Fundamentally, three phenomena (crack tip diversion, crack front bifurcation and metal crumb formation) were observed to influence the rate of FCG. These phenomena appear to be a function of the material microstructure, environment and crack tip loading conditions. The three factors retarded the crack growth by reducing or redistributing the effective driving force at the main active crack tip. A crack path containing extensively the three phenomena was observed to offer strong resistance to FCG. In SW, the degree of the electrochemical dissolution of the microplastic zone appears to be an additional primary factor influencing FCG in the steel
Real-time observations of TRIP-induced ultrahigh strain hardening in a dual-phase CrMnFeCoNi high-entropy alloy
Strategies involving metastable phases have been the basis of the design of numerous alloys, yet research on metastable high-entropy alloys is still in its infancy. In dual-phase high-entropy alloys, the combination of local chemical environments and loading-induced crystal structure changes suggests a relationship between deformation mechanisms and chemical atomic distribution, which we examine in here in a Cantor-like Cr20Mn6Fe34Co34Ni6 alloy, comprising both face-centered cubic (fcc) and hexagonal closed packed (hcp) phases. We observe that partial dislocation activities result in stable three-dimensional stacking-fault networks. Additionally, the fraction of the stronger hcp phase progressively increases during plastic deformation by forming at the stacking-fault network boundaries in the fcc phase, serving as the major source of strain hardening. In this context, variations in local chemical composition promote a high density of Lomer-Cottrell locks, which facilitate the construction of the stacking-fault networks to provide nucleation sites for the hcp phase transformation
Facile self-assembly synthesis of gamma-Fe2O3/graphene oxide for enhanced photo-Fenton reaction
A novel self-assembly method was developed to prepare a γ-Fe2O3/graphene oxide (GO) heterogeneous catalyst that showed excellent synergy between photocatalysis and Fenton-like reactions. The γ-Fe2O3/GO catalyst prepared on the iron plates demonstrated efficient and reproducible catalytic activities for water treatment. It takes only 80 min to degrade 50 mg L−1 methylene (MB) completely, which is the main non-biodegradable dye in wastewater from the textile industry. The heterogeneous catalyst is stable over a wide range of pH (from 2.0 to 10.2) for MB degradation, and can be easily extracted from solution and repeatedly used with little loss of catalytic activity. The high activity and stability of the catalyst system can be attributed to charge separation between γ-Fe2O3 and GO, which could accelerate Fenton-like process and photocatalysis. In addition, the dominant reactive oxidant species responsible for the MB degradation, including the hydroxyl radicals (•OH) and holes (h+), were trapped on the surface of the γ-Fe2O3/GO composite, as proved by a free-radical quenching experiment. The γ-Fe2O3/GO heterogeneous catalyst could potentially provide a solution for removal of non-biodegradable dyes from wastewater in the textile industry
Tensile Overload and Stress Intensity Shielding Investigations by Ultrasound
Growth of a fatigue crack is modified according to the development of contacts between the crack faces [1,2] creating shielding, thus canceling a portion of the crack driving force. These contacts develop through a number of mechanisms, including plastic deformation, sliding of the faces with respect to each other and the collection of debris such as oxide particles [3]. Compressive stresses are created on either side of the partially contacting crack faces resulting in opening loads that must be overcome in order to apply a driving force at the crack tip. In this way, the crack tip is shielded from a portion of the applied load, thus creating the need for modification [1] of the applied stress intensity range from ΔK = KImax − KImin to ΔKeff = KImax − KIsh. Determination of the contact size and density in the region of closure from ultrasonic transmission and diffraction experiments [4] has allowed estimation of the magnitude of Kish on a crack grown under constant ΔK conditions. The calculation has since [5] been extended to fatigue cracks grown with a tensile overload block. The calculation was also successful in predicting the growth rate of the crack after reinitiation had occurred. This paper reports the further extension to the effects of a variable ΔK on fatigue crack growth. In addition, this paper presents preliminary results on detection of the tightly closed crack extension present during the growth retardation period after application of a tensile overload as well as an observation of the crack surface during reinitiation of growth that presents some interesting questions
Edge Weld Penetration Assessment via Electric Current Deflection Measurements
Because of the awkward and somewhat irregular shape of the weldment, conventional methods [1] could not be adapted to the nondestructive measurement of GTAW edge weld penetration on clamshell-style catalytic converters and a special inspection system based on the electric current deflection method was developed. DC or low-frequency AC electric resistance measurements, also known as the Potential Drop Method (PDM), are well-developed for plate thickness assessment and crack detection [2–6]. The operating principle of these methods is that, under certain arrangement of the electrodes, the defect or crack in a conducting specimen will cause a measurable increase in resistance between given points compared to the situation without the defect or crack. In recent years, this simple contact technique was largely obscured by more sophisticated noncontacting eddy-current techniques especially in industrial applications. In this article, we demonstrate the distinct advantages of the Potential Drop Method through the example of GTAW edge welds where the awkward shape of the specimens and the required large penetration depth render the eddy-current method less feasible.</p
What are we measuring? A critique of range of motion methods currently in use for Dupuytren's disease and recommendations for practice
Background: Range of motion is the most frequently reported measure used in practice to evaluate outcomes.
A goniometer is the most reliable tool to assess range of motion yet, the lack of consistency in reporting prevents comparison between studies. The aim of this study is to identify how range of motion is currently assessed and reported in Dupuytren’s disease literature. Following analysis recommendations for practice will be made to enable consistency in future studies for comparability. This paper highlights the variation in range of motion reporting in Dupuytren’s disease.
Methods: A Participants, Intervention, Comparison, Outcomes and Study design format was used for the search strategy and search terms. Surgery, needle fasciotomy or collagenase injection for primary or recurrent Dupuytren’s disease in adults were included if outcomes were monitored using range of motion to record change. A literature search was performed in May 2013 using subject heading and free-text terms to also capture electronic publications ahead of print. In total 638 publications were identified and following screening 90 articles met the inclusion criteria. Data was extracted and entered onto a spreadsheet for analysis. A thematic analysis was carried out to establish any duplication, resulting in the final range of motion measures identified.
Results: Range of motion measurement lacked clarity, with goniometry reportedly used in only 43 of the 90 studies, 16 stated the use of a range of motion protocol. A total of 24 different descriptors were identified describing range of motion in the 90 studies. While some studies reported active range of motion, others reported passive or were unclear. Eight of the 24 categories were identified through thematic analysis as possibly describing the same measure, ‘lack of joint extension’ and accounted for the most frequently used. Conclusions: Published studies lacked clarity in reporting range of motion, preventing data comparison and
meta-analysis. Percentage change lacks context and without access to raw data, does not allow direct comparison of baseline characteristics. A clear description of what is being measured within each study was required. It is recommended that range of motion measuring and reporting for Dupuytren’s disease requires consistency to address issues that fall into 3 main categories:-
Definition of terms
Protocol statement
Outcome reportin
Optimal functional outcome measures for assessing treatment for Dupuytren's disease: A systematic review and recommendations for future practice
This article is available through the Brunel Open Access Publishing Fund. Copyright © 2013 Ball et al.; licensee BioMed Central Ltd.Background: Dupuytren's disease of the hand is a common condition affecting the palmar fascia, resulting in progressive flexion deformities of the digits and hence limitation of hand function. The optimal treatment remains unclear as outcomes studies have used a variety of measures for assessment. Methods: A literature search was performed for all publications describing surgical treatment, percutaneous needle aponeurotomy or collagenase injection for primary or recurrent Dupuytren’s disease where outcomes had been monitored using functional measures. Results: Ninety-one studies met the inclusion criteria. Twenty-two studies reported outcomes using patient reported outcome measures (PROMs) ranging from validated questionnaires to self-reported measures for return to work and self-rated disability. The Disability of Arm, Shoulder and Hand (DASH) score was the most utilised patient-reported function measure (n=11). Patient satisfaction was reported by eighteen studies but no single method was used consistently. Range of movement was the most frequent physical measure and was reported in all 91 studies. However, the methods of measurement and reporting varied, with seventeen different techniques being used. Other physical measures included grip and pinch strength and sensibility, again with variations in measurement protocols. The mean follow-up time ranged from 2 weeks to 17 years. Conclusions: There is little consistency in the reporting of outcomes for interventions in patients with Dupuytren’s disease, making it impossible to compare the efficacy of different treatment modalities. Although there are limitations to the existing generic patient reported outcomes measures, a combination of these together with a disease-specific questionnaire, and physical measures of active and passive individual joint Range of movement (ROM), grip and sensibility using standardised protocols should be used for future outcomes studies. As Dupuytren’s disease tends to recur following treatment as well as extend to involve other areas of the hand, follow-up times should be standardised and designed to capture both short and long term outcomes
- …