74 research outputs found

    Respiratory influence on left atrial volume calculation with 3D-echocardiography

    Get PDF
    BACKGROUND: Left atrial volume (LAV) estimation with 3D echocardiography has been shown to be more accurate than 2D volume calculation. However, little is known about the possible effect of respiratory movements on the accuracy of the measurement. METHODS: 100 consecutive patients admitted with chest pain were examined with 3D echocardiography and LAV was quantified during inspiratory breath hold, expiratory breath hold and during free breathing. RESULTS: Of the 100 patients, only 65 had an echocardiographic window that allowed for 3D echocardiography in the entire respiratory cycle. Mean atrial end diastolic volume was 45.4 ± 14.5 during inspiratory breath hold, 46.4 ± 14.8 during expiratory breath hold and 45.6 ± 14.3 during free respiration. Mean end systolic volume was 17.6 ± 7.8 during inspiratory breath hold, 18.8 ± 8.0 during expiratory breath hold and 18.3 ± 8.0 during free respiration. No significant differences were seen in any of the measured parameters. CONCLUSIONS: The present study adds to the feasibility of 3D LAV quantitation. LAV estimation by 3D echocardiography may be performed during either end-expiratory or end-inspiratory breath-hold without any significant difference in the calculated volume. Also, the LAV estimation may be performed during free breathing

    The Association of a classical left bundle Branch Block Contraction Pattern by vendor-independent strain echocardiography and outcome after cardiac resynchronization therapy

    Get PDF
    Background: The association of a Classical left bundle branch block (LBBB) contraction pattern and better outcome after cardiac resynchronization therapy (CRT) has only been studied using vendor-specific software for echocardiographic speckle-tracked longitudinal strain analysis. The purpose of this study was to assess whether a Classical LBBB contraction pattern on longitudinal strain analysis using vendor-independent software is associated with clinical outcome in CRT recipients with LBBB. Methods: This was a retrospective cohort study including CRT recipients with LBBB, heart failure, and left ventricular (LV) ejection fraction ≤35%. Speckle-tracked echocardiographic longitudinal strain analysis was performed retrospectively on echocardiograms using vendor-independent software. The presence of a Classical LBBB contraction pattern was determined by consensus of two readers. The primary end point was a composite of time to death, heart transplantation or LV assist device implantation. Secondary outcome was ≥15% reduction in LV end-systolic volume. Intra- and inter-reader agreement of the longitudinal strain contraction pattern was assessed by calculating Cohen's κ. Results: Of 283 included patients, 113 (40%) were women, mean age was 66 ± 11 years, and 136 (48%) had ischemic heart disease. A Classical LBBB contraction pattern was present in 196 (69%). The unadjusted hazard ratio for reaching the primary end point was 1.93 (95% confidence interval, 1.36-2.76, p &lt; 0.001) when comparing patients without to patients with a Classical LBBB contraction pattern. Adjusted for ischemic heart disease and QRS duration &lt; 150 milliseconds the hazard ratio was 1.65 (95% confidence interval, 1.12-2.43, p = 0.01). Of the 123 (43%) patients with a follow-up echocardiogram, 64 of 85 (75%) of patients with a Classical LBBB contraction pattern compared to 13 of 38 (34%) without, had ≥15% reduction in LV end-systolic volume (p &lt; 0.001). Cohen's κ were 0.86 (95% confidence interval, 0.71-1.00) and 0.42 (95% confidence interval, 0.30-0.54) for intra- and inter-reader agreement, respectively. Conclusion: Using vendor-independent strain software, a Classical LBBB contraction pattern is associated with better outcome in CRT recipients with LBBB, but inter-reader agreement for the classification of contraction pattern is only moderate.</p

    Cardiac resynchronization therapy in patients with heart failure and narrow QRS complexes

    Get PDF
    Background: Cross correlation analysis (CCA) using tissue Doppler imaging has been shown to be associated with outcome after cardiac resynchronization therapy (CRT) in patients with heart failure (HF) with wide QRS. However, its significance in patients with narrow QRS treated with CRT is unknown. Objectives: The aim of the current study was to investigate the association of mechanical activation delay by CCA with study outcome in patients with HF enrolled in the EchoCRT trial. Methods: Baseline CCA could be performed from tissue Doppler imaging in the apical views in 807 of 809 (99.7%) enrolled patients, and 6-month follow-up could be performed in 610 of 635 (96%) patients with available echocardiograms. Patients with a pre-specified maximal activation delay ≥35 ms were considered to have significant delay. The study outcome was HF hospitalization or death. Results: Of 807 patients, 375 (46%) did not have delayed mechanical activation at baseline by CCA. Patients without delayed mechanical activation who were randomized to CRT-On compared with CRT-Off had an increased risk of poor outcome (hazard ratio: 1.70; 95% confidence interval: 1.13 to 2.55; p = 0.01) with a significant interaction term (p = 0.04) between delayed mechanical activation and device randomization for the endpoint. Among patients with paired baseline and follow-up data with no events before 6-month follow-up (n = 541), new-onset delayed mechanical activation in the CRT-On group showed a significant increase in unfavorable events (hazard ratio: 3.73; 95% confidence interval: 1.15 to 12.14; p = 0.03). Conclusions: In the EchoCRT population, absence of delayed mechanical activation by CCA was significantly associated with poor outcomes, possibly due to the onset of new delayed mechanical activation with CRT pacing. (Echocardiography Guided Cardiac Resynchronization Therapy [EchoCRT] Trial; NCT00683696)

    Reply

    No full text

    Why Dyssynchrony Matters in Heart Failure?