47 research outputs found
Radiation dose of chaperones during common pediatric computed tomography examinations
Background
One main challenge in pediatric imaging is to reduce motion artifacts by calming young patients. To that end, the Radiological Society of North America (RSNA) as early as 1997 stated the necessity of adults accompanying their child during the childâs examination. Nonetheless, current research lacks data regarding radiation dose to these chaperones.
Objective
The aim of this study was to measure the radiation dose of accompanying adults during state-of-the-art pediatric CT protocols.
Materials and methods
In addition to a 100-kV non-contrast-enhanced chest CT (Protocol 1), we performed a 70-kV contrast-enhanced chest protocol (Protocol 2) using a third-generation dual-source CT. We acquired data on the radiation dose around the scanner using digital dosimetry placed right at the gantry, 1 m away, as well as beside the gantry. We acquired the CT-surrounding radiation dose during scanning of a pediatric phantom as well as 12 pediatric patients.
Results
After conducting 10 consecutive phantom scans using Protocol 1, we found the location with the highest cumulative dose acquired was right next to the gantry opening, at 3 ΌSv. Protocol 2 showed highest cumulative dose of 2 ΌSv at the same location. For Protocol 1, the location with the highest radiation doses during pediatric scans was right next to the gantry opening, with doses of 0.75±0.70 ΌSv. For Protocol 2, the highest radiation was measured 1 m away at 0.50±0.60 ΌSv. No radiation dose was measured at any time beside the gantry.
Conclusion
Our results provide proof that chaperones receive low radiation doses during state-of-the-art CT examinations. Given knowledge of these values as well as the optimal spots with the lowest radiation doses, parents as well as patients might be more relaxed during the examination
Incidental finding of a giant intracardiac angioma infiltrating both ventricles in a 35-year-old woman: a case report
Background: Primary cardiac tumors are rare and often asymptomatic or present with unspecific symptoms. Benign cardiac tumors of vascular origin are especially rare, with only few existing data in the literature. Case presentation: A 35-year-old Caucasian female patient presented to our department with an asymptomatic giant intracardiac angioma infiltrating both ventricles. Evaluation of this tumor involved electrocardiography, echocardiography, cardiac magnetic resonance imaging, coronary angiography, an open myocardial biopsy, and histological examination of the resected specimen. Because our patient was asymptomatic, she was managed conservatively with regular follow-up. We discuss the treatment options available in comparison with similar cases. Conclusion: Diagnosis and therapy of benign cardiac tumors, especially of asymptomatic lesions, can be a challenge. There is no evidence available to help in the management of such patients. An extensive evaluation is needed with different imaging modalities, and case-specific decisions should be made that involve experts in cardiology, cardio-oncology, and heart surgery
Pericoronary radiomics texture features associated with hypercholesterolemia on a photon-counting-CT
IntroductionPericoronary adipose tissue (PCAT) stands in complex bidirectional interaction with the surrounding arteries and is known to be connected to many cardiovascular diseases involving vascular inflammation. PCAT texture may be influenced by other cardiovascular risk factors such as hypercholesterolemia. The recently established photon-counting CT could improve texture analysis and help detect those changes by offering higher spatial resolution and signal-to-noise ratio.MethodsIn this retrospective, single-center, IRB-approved study, PCAT of the left and right coronary artery was manually segmented and radiomic features were extracted using pyradiomics. The study population consisted of a test collective and a validation collective. The collectives were each divided into two groups defined by the presence or absence of hypercholesterolemia, taken from self-reported conditions and confirmed by medical records. Mean and standard deviation were calculated with Pearson correlation coefficient for correlation of features and visualized as boxplots and heatmaps using R statistics. Random forest feature selection was performed to identify differentiating features between the two groups. 66 patients were enrolled in this study (34 female, mean age 58 years).ResultsTwo radiomics features allowing differentiation between PCAT texture of the groups were identified (p-values between 0.013 and 0.24) and validated. Patients with hypercholesterolemia presented with a greater concentration of high-density values as indicated through analysis of specific texture features as âgldm_HighGrayLevelEmphasisâ (23.95 vs. 22.99) and âglrlm_HighGrayLevelRunEmphasisâ (24.21 vs. 23.31).DiscussionTexture analysis of PCAT allowed differentiation between patients with and without hypercholesterolemia offering a potential imaging biomarker for this specific cardiovascular risk factor
Serum amyloid A: high-density lipoproteins interaction and cardiovascular risk
Aims High-density lipoproteins (HDLs) are considered as anti-atherogenic. Recent experimental findings suggest that their biological properties can be modified in certain clinical conditions by accumulation of serum amyloid A (SAA). The effect of SAA on the association between HDL-cholesterol (HDL-C) and cardiovascular outcome remains unknown. Methods and results We examined the association of SAA and HDL-C with mortality in the Ludwigshafen Risk and Cardiovascular Health (LURIC) study, which included 3310 patients undergoing coronary angiography. To validate our findings, we analysed 1255 participants of the German Diabetes and Dialysis study (4D) and 4027 participants of the Cooperative Health Research in the Region of Augsburg (KORA) S4 study. In LURIC, SAA concentrations predicted all-cause and cardiovascular mortality. In patients with low SAA, higher HDL-C was associated with lower all-cause and cardiovascular mortality. In contrast, in patients with high SAA, higher HDL-C was associated with increased all-cause and cardiovascular mortality, indicating that SAA indeed modifies the beneficial properties of HDL. We complemented these clinical observations by in vitro experiments, in which SAA impaired vascular functions of HDL. We further derived a formula for the simple calculation of the amount of biologically âeffective' HDL-C based on measured HDL-C and SAA from the LURIC study. In 4D and KORA S4 studies, we found that measured HDL-C was not associated with clinical outcomes, whereas calculated âeffective' HDL-C significantly predicted better outcome. Conclusion The acute-phase protein SAA modifies the biological effects of HDL-C in several clinical conditions. The concomitant measurement of SAA is a simple, useful, and clinically applicable surrogate for the vascular functionality of HD
Left ventricular long axis strain: a new prognosticator in non-ischemic dilated cardiomyopathy?
Background: Long axis strain (LAS) has been shown to be a fast assessable parameter representing global left ventricular (LV) longitudinal function in cardiovascular magnetic resonance (CMR). However, the prognostic value of LAS in cardiomyopathies with reduced left ventricular ejection fraction (LVEF) has not been evaluated yet. Methods and results: In 146 subjects with non-ischemic dilated cardiomyopathy (NIDCM, LVEF â€45 %) LAS was assessed retrospectively from standard non-contrast SSFP cine sequences by measuring the distance between the epicardial border of the left ventricular apex and the midpoint of a line connecting the origins of the mitral valve leaflets in end-systole and end-diastole. The final values were calculated according to the strain formula. The primary endpoint of the study was defined as a combination of cardiac death, heart transplantation or aborted sudden cardiac death and occurred in 24 subjects during follow-up. Patients with LAS values >ââ5 % showed a significant higher rate of cardiac events independent of the presence of late gadolinium enhancement (LGE). The multivariate Cox regression analysis revealed that LVEDV/BSA (HR: 1.01, pâââ10 % and the presence of LGE, patients with 3 points had a significantly higher risk for cardiac events than those with 2 or less points. Conclusion: Assessment of long axis function with LAS offers significant incremental information for the prediction of cardiac events in NIDCM and improves risk stratification beyond established CMR parameters
Implementation of Dual-Source RF Excitation in 3 T MR-Scanners Allows for Nearly Identical ADC Values Compared to 1.5 T MR Scanners in the Abdomen
Background: To retrospectively and prospectively compare abdominal apparent diffusion coefficient (ADC) values obtained within in a 1.5 T system and 3 T systems with and without dual-source parallel RF excitation techniques. Methodology/Principal Findings: After IRB approval, diffusion-weighted (DW) images of the abdomen were obtained on three different MR systems (1.5 T, a first generation 3 T, and a second generation 3 T which incorporates dual-source parallel RF excitation) on 150 patients retrospectively and 19 volunteers (57 examinations total) prospectively. Seven regions of interest (ROI) were throughout the abdomen were selected to measure the ADC. Statistical analysis included independent two-sided t-tests, Mann-Whitney U tests and correlation analysis. In the DW images of the abdomen, mean ADC values were nearly identical with nonsignificant differences when comparing the 1.5 T and second generation 3 T systems in all seven anatomical regions in the patient population and six of the seven in the volunteer population (p.0.05 in all distributions). The strength of correlation measured in the volunteer population between the two scanners in the kidneys ranged from r = 0.64â0.88 and in the remaining regions (besides the spleen), r.0.85. In the patient population the first generation 3 T scanner had different mean ADC values with significant differences (p,0.05) compared to the other two scanners in each of the seven distributions. In the volunteer population, the kidneys shared similar ADC mean values in comparison to the other two scanners with nonsignificant differences
Characterization of a new keratinolytic bacterium that completely degrades native feather keratin.
International audienceA novel feather-degrading microorganism was isolated from poultry waste, producing a high keratinolytic activity when cultured on broth containing native feather. Complete feather degradation was achieved during cultivation. The bacterium presents potential use for biotechnological processes involving keratin hydrolysis. Chryseobacterium sp. strain kr6 was identified based on morphological and biochemical tests and 16S rRNA sequencing. The bacterium presented optimum growth at pH 8.0 and 30 degrees C; under these conditions, maximum feather-degrading activity was also achieved. Maximum keratinase production was reached at 25 degrees C, while concentration of soluble protein was similar at both 25 and 30 degrees C. Reduction of disulfide bridges was also observed, increasing with cultivation time. The keratinase of strain kr6 was active on azokeratin and azocasein as substrates, and presented optimum pH and temperature of 7.5 and 55 degrees C, respectively. The keratinase activity was inhibited by 1,10-phenanthroline, EDTA, Hg(2+), and Cu(2+) and stimulated by Ca(2+)
Impact of Multiparametric Stone Measurement in Noncontrast Computer Tomography on Ureterorenoscopic Stone Removal
Purpose: Low-dose computer tomography (NCCT) is the standard imaging modality for patients with acute flank pain with a suspicion of urolithiasis. The stone size is usually measured 2D by a radiologist. We compared 3D stone measurement using different windows to the 2D measurement and evaluated the clinical impact on ureterorenoscopic stone removal (URS). Methods: One hundred sixty-four patients (201 stones) with a preoperative NCCT, following a URS within 4 weeks, were included in this study. Stone location, number and size of stones, operating time, and laser lithotripsy were documented. Stones were measured in 3D using bone and soft tissue window. The maximum diameter was compared to the radiological report. The U test, Kruskal-Wallis, and regression were used for statistical analyses. Results: Almost two-thirds (64.68%; 130 stones) of stone measurements in 3D with the bone window were lower than the radiologist reports in 2D. One-third (34.83%; 70 stones) of stone measurements were higher and 0.5% (1 stone) reported the same size. Using the 3D soft tissue window, 81.09% (163 stones), 17.91% (37 stones), and 1% (2 stones) of stones were measured bigger, smaller, or had the same measurement results, respectively. In the clinical setting, we could calculate a cutoff for laser lithotripsy at a maximum stone diameter of 5.70 mm (p < 0.01) with the 3D and 6.01 mm with the 2D measurements, respectively, and found a significant correlation between maximum stone diameter and operating time (p < 0.01) and number of stones and operating time (p < 0.01 with and p = 0.02 without laser). Conclusion: 3D stone measurement with bone window seems to be more accurate than 2D measurement, but 2D is sufficient for planning stone treatment. (c) 2021 S. Karger AG, Base