359 research outputs found

    An active interferometric method for extreme impedance on-wafer device measurements

    Get PDF
    Nano-scale devices and high-power transistors present extreme impedances, which are far removed from the 50-Ω reference impedance of conventional test equipment, resulting in a reduction in the measurement sensitivity as compared with impedances close to the reference impedance. This letter describes a novel method based on active interferometry to increase the measurement sensitivity of a vector network analyzer for measuring such extreme impedances, using only a single coupler. The theory of the method is explained with supporting simulation. An interferometry-based method is demonstrated for the first time with on-wafer measurements, resulting in an improved measurement sensitivity for extreme impedance device characterization of up to 9%

    Metrology State-of-the-Art and Challenges in Broadband Phase-Sensitive Terahertz Measurements

    Get PDF
    The two main modalities for making broadband phase-sensitive measurements at terahertz (THz) frequencies are vector network analyzers (VNA) and time-domain spectrometers (TDS). These measuring instruments have separate and fundamentally different operating principles and methodologies, and they serve very different application spaces. The different architectures give rise to different measurement challenges and metrological solutions. This article reviews these two measurement techniques and discusses the different issues involved in making measurements using these systems. Calibration, verification, and measurement traceability issues are reviewed, along with other major challenges facing these instrument architectures in the years to come. The differences in, and similarities between, the two measurement methods are discussed and analyzed. Finally, the operating principles of electro-optic sampling (EOS) are briefly discussed. This technique has some similarities to TDS and shares application space with the VNA

    3-D printing quantization predistortion applied to sub-THz chained-function filters

    Get PDF
    This paper investigates physical dimension limits associated with the low-cost, polymer-based masked stereolithography apparatus (MSLA) 3-D printer, with 50 μm pixels defining the minimum print feature size. Based on the discretization properties of our MSLA 3-D printer, multi-step quantization predistortion is introduced to correct for registration errors between the CAD drawing and slicing software. This methodology is applied to G-band 5th order metal-pipe rectangular waveguide filters, where the pixel pitch has an equivalent electrical length of 8.5° at center frequency. When compared to the reference Chebyshev filter, our chained-function filter exhibits superior S-parameter measurements, with a low insertion loss of only 0.6 dB at its center frequency of 182 GHz, having a 0.9% frequency shift, and an acceptable worst-case passband return loss of 13 dB. Moreover, with measured dimensions after the 3-D printed parts have been commercially electroplated with a 50 μm thick layer of copper, the re-simulations are in good agreement with the S-parameter measurements. For the first time, systematic (quantization) errors associated with a pixel-based 3-D printer have been characterized and our robust predistortion methodology has been successfully demonstrated with an upper-millimeter-wave circuit. Indeed, we report the first polymer-based 3-D printed filters that operate above W-band. As pixel sizes continue to shrink, more resilient (sub-)THz filters with ever-higher frequencies of operation and more demanding specifications can be 3-D printed. Moreover, our work opens-up new opportunities for any pixel-based technology, which exhibits registration errors, with its application critically dependent on its minimum feature size

    Polymer-based 3-D printed 140 to 220 GHz metal waveguide thru lines, twist and filters

    Get PDF
    This paper demonstrates the current state-of-the-art in low-cost, low loss ruggedized polymer-based 3-D printed G-band (140 to 220 GHz) metal-pipe rectangular waveguide (MPRWG) components. From a unique and exhaustive up-to-date literature review, the main limitations for G-band split-block MPRWGs are identified as electromagnetic (EM) radiation leakage, assembly part alignment and manufacturing accuracy. To mitigate against leakage and misalignment, we investigate a ‘trough-and-lid’ split-block solution. This approach is successfully employed in proof-of-concept thru lines, and in the first polymer-based 3-D printed 90° twist and symmetrical diaphragm inductive iris-coupled bandpass filters (BPFs) operating above 110 GHz. An inexpensive desktop masked stereolithography apparatus 3-D printer and a commercial copper electroplating service are used. Surface roughness losses are calculated and applied to EM (re-)simulations, using two modifications of the Hemispherical model. The 7.4 mm thru line exhibits a measured average dissipative attenuation of only 12.7 dB/m, with rectangular-to-trapezoidal cross-sectional distortion being the main contributor to loss. The 90° twist exhibits commensurate measured performance to its commercial counterpart, despite the much lower manufacturing costs. A detailed time-domain reflectometry analysis of flange quality for the thru lines and 90° twists has also been included. Finally, a new systematic iris corner rounding compensation technique, to correct passband frequency down-shifting is applied to two BPFs. Here, the 175 GHz exemplar exhibits only 0.5% center frequency up-shifting. The trough-and-lid assembly is now a viable solution for new upper-mm-wave MPRWG components. With this technology becoming less expensive and more accurate, higher frequencies and/or more demanding specifications can be implemented

    3-D Printed Plug and Play Prototyping for Low-cost Sub-THz Subsystems

    Get PDF
    Polymer-based additive manufacturing using 3-D printing for upper-millimeter-wave ( ca. 100 to 300 GHz) frequency applications is now emerging. Building on our previous work, with metal-pipe rectangular waveguides and free-space quasi-optical components, this paper brings the two media together at G-band (140 to 220 GHz), by demonstrating a compact multi-channel front-end subsystem. Here, the proof-of-concept demonstrator integrates eight different types of 3-D printed components (30 individual components in total). In addition, the housing for two test platforms and the subsystem are all 3-D printed as single pieces, to support plug and play development; offering effortless component assembly and alignment. We introduce bespoke free-space TRM calibration and measurement schemes with our quasi-optical test platforms. Equal power splitting plays a critical role in our multi-channel application. Here, we introduce a broadband 3-D printed quasi-optical beamsplitter for upper-millimeter-wave applications. Our quantitative and/or qualitative performance evaluations for individual components and the complete integrated subsystem, demonstrate the potential for using consumer-level desktop 3-D printing technologies at such high frequencies. This work opens-up new opportunities for low-cost, rapid prototyping and small-batch production of complete millimeter-wave front-end subsystems

    Protocol for a qualitative study exploring perspectives on the INternational CLassification of Diseases (11th revision); Using lived experience to improve mental health Diagnosis in NHS England: INCLUDE study

    Get PDF
    Introduction: Developed in dialogue with WHO, this research aims to incorporate lived experience and views in the refinement of the International Classification of Diseases Mental and Behavioural Disorders 11th Revision (ICD-11). The validity and clinical utility of psychiatric diagnostic systems has been questioned by both service users and clinicians, as not all aspects reflect their lived experience or are user friendly. This is critical as evidence suggests that diagnosis can impact service user experience, identity, service use and outcomes. Feedback and recommendations from service users and clinicians should help minimise the potential for unintended negative consequences and improve the accuracy, validity and clinical utility of the ICD-11. Methods and analysis: The name INCLUDE reflects the value of expertise by experience as all aspects of the proposed study are co-produced. Feedback on the planned criteria for the ICD-11 will be sought through focus groups with service users and clinicians. The data from these groups will be coded and inductively analysed using a thematic analysis approach. Findings from this will be used to form the basis of co-produced recommendations for the ICD-11. Two service user focus groups will be conducted for each of these diagnoses: Personality Disorder, Bipolar I Disorder, Schizophrenia, Depressive Disorder and Generalised Anxiety Disorder. There will be four focus groups with clinicians (psychiatrists, general practitioners and clinical psychologists). Ethics and dissemination: This study has received ethical approval from the Coventry and Warwickshire HRA Research Ethics Committee (16/WM/0479). The output for the project will be recommendations that reflect the views and experiences of experts by experience (service users and clinicians). The findings will be disseminated via conferences and peer-reviewed publications. As the ICD is an international tool, the aim is for the methodology to be internationally disseminated for replication by other groups

    3-D printed rectangular waveguide 123-129 GHz packaging for commercial CMOS RFICs

    Get PDF
    This work demonstrates the hybrid integration of a complementary metal–oxide–semiconductor (CMOS) radio frequency integrated circuit (RFIC) into a host 3-D printed metal-pipe rectangular waveguide (MPRWG). On-chip Vivaldi antennas are used for TE 10 -to-thin-film microstrip (TFMS) mode conversion. Our packaging solution has a combined measured insertion loss of only 1 dB/transition at 126 GHz. This unique packaging and interconnect solution opens up new opportunities for implementing low-cost subterahertz (THz) multichip modules

    C9orf72 repeat expansions cause neurodegeneration in Drosophila through arginine-rich proteins

    Get PDF
    An expanded GGGGCC repeat in C9orf72 is the most common genetic cause of frontotemporal dementia and amyotrophic lateral sclerosis. A fundamental question is whether toxicity is driven by the repeat RNA itself and/or by dipeptide repeat proteins generated by repeat-associated, non-ATG translation. To address this question we developed in vitro and in vivo models to dissect repeat RNA and dipeptide repeat protein toxicity. Expression of pure repeats in Drosophila caused adult-onset neurodegeneration attributable to poly-(glycine-arginine) proteins. Thus, expanded repeats promoted neurodegeneration through neurotoxic proteins. Expression of individual dipeptide repeat proteins with a non-GGGGCC RNA sequence showed both poly-(glycine-arginine) and poly-(proline-arginine) proteins caused neurodegeneration. These findings are consistent with a dual toxicity mechanism, whereby both arginine-rich proteins and repeat RNA contribute to C9orf72-mediated neurodegeneration
    • …
    corecore