1,169 research outputs found

    On the Virtualization of Audio Transducers

    Get PDF
    In audio transduction applications, virtualization can be defined as the task of digitally altering the acoustic behavior of an audio sensor or actuator with the aim of mimicking that of a target transducer. Recently, a digital signal preprocessing method for the virtualization of loudspeakers based on inverse equivalent circuit modeling has been proposed. The method applies Leuciuc’s inversion theorem to obtain the inverse circuital model of the physical actuator, which is then exploited to impose a target behavior through the so called Direct–Inverse–Direct Chain. The inverse model is designed by properly augmenting the direct model with a theoretical two-port circuit element called nullor. Drawing on this promising results, in this manuscript, we aim at describing the virtualization task in a broader sense, including both actuator and sensor virtualizations. We provide ready-to-use schemes and block diagrams which apply to all the possible combinations of input and output variables. We then analyze and formalize different versions of the Direct–Inverse–Direct Chain describing how the method changes when applied to sensors and actuators. Finally, we provide examples of applications considering the virtualization of a capacitive microphone and a nonlinear compression driver

    Intraoperative β-Detecting probe for radio-guided surgery in tumour resection

    Get PDF
    The development of the β− based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma and gliomas already estimated the potentiality of this new treatment. To validate the technique, a prototype of the intraoperative probe detecting β− decays and specific phantoms simulating tumour remnant patterns embedded in healthy tissue have been realized. The response of the probe in this simulated environment is tested with dedicated procedures. This document discusses the innovative aspects of the method, the status of the developed intraoperative β− detecting probe and the results of the preclinical tests

    An Intraoperative β−\beta^- Detecting Probe For Radio-Guided Surgery in Tumour Resection

    Get PDF
    The development of the β−\beta^- based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma, glioma, and neuroendocrine tumors already estimated the potentiality of this new treatment. To validate the technique, prototypes of the intraoperative probe required by the technique to detect β−\beta^- radiation have been developed. This paper discusses the design details of the device and the tests performed in laboratory. In such tests particular care has to be taken to reproduce the surgical field conditions. The innovative technique to produce specific phantoms and the dedicated testing protocols is described in detail.Comment: 7 pages, 15 figure

    Monitoring of hadrontherapy treatments by means of charged particle detection

    Get PDF
    The interaction of the incoming beam radiation with the patient body in hadrontherapy treatments produces secondary charged and neutral particles, whose detection can be used for monitoring purposes and to perform an on-line check of beam particle range. In the context of ion-therapy with active scanning, charged particles are potentially attractive since they can be easily tracked with a high efficiency, in presence of a relatively low background contamination. In order to verify the possibility of exploiting this approach for in-beam monitoring in ion-therapy, and to guide the design of specific detectors, both simulations and experimental tests are being performed with ion beams impinging on simple homogeneous tissue-like targets (PMMA). From these studies, a resolution of the order of few millimeters on the single track has been proven to be sufficient to exploit charged particle tracking for monitoring purposes, preserving the precision achievable on longitudinal shape. The results obtained so far show that the measurement of charged particles can be successfully implemented in a technology capable of monitoring both the dose profile and the position of the Bragg peak inside the target and finally lead to the design of a novel profile detector. Crucial aspects to be considered are the detector positioning, to be optimized in order to maximize the available statistics, and the capability of accounting for the multiple scattering interactions undergone by the charged fragments along their exit path from the patient body. The experimental results collected up to now are also valuable for the validation of Monte Carlo simulation software tools and their implementation in Treatment Planning Software packages

    Molybdenum oxides coatings for high demanding accelerator components

    Get PDF
    Large electric gradients are required for a variety of new applications, notably including the extreme high brightness electron sources for X-ray free electron lasers (FELs), radio-frequency (RF) photo-injectors, industrial and medical accelerators, and linear accelerators for particle physics colliders. In the framework of the INFN-LNF, SLAC (USA), KEK (Japan), UCLA (Los Angeles) collaboration, the Frascati National Laboratories (LNF) are involved in the modelling, development, and testing of RF structures devoted to particles acceleration by high gradient electric fields of particles through metal devices. In order to improve the maximum sustainable gradients in normal-conducting RF-accelerating structures, both the RF breakdown and dark current should be minimized. To this purpose, studying new materials as well as manufacturing techniques are mandatory to identify better solutions to such extremely requested applications. In this contribution, we discuss the possibility of using a dedicated coating on a solid copper sample (and other metals) with a relatively thick film to improve and optimize breakdown performances and to minimize the dark current. We present here the first characterization of MoO3 films deposited on copper by pulsed-laser deposition (PLD)

    Towards a Radio-guided Surgery with β−\beta^{-} Decays: Uptake of a somatostatin analogue (DOTATOC) in Meningioma and High Grade Glioma

    Full text link
    A novel radio guided surgery (RGS) technique for cerebral tumors using β−\beta^{-} radiation is being developed. Checking the availability of a radio-tracer that can deliver a β−\beta^{-} emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study of the RGS technique in these cases.Comment: 21 pages, 5 figure

    Measurement of charged particle yields from therapeutic beams in view of the design of an innovative hadrontherapy dose monitor

    Get PDF
    Particle Therapy (PT) is an emerging technique, which makes use of charged particles to efficiently cure different kinds of solid tumors. The high precision in the hadrons dose deposition requires an accurate monitoring to prevent the risk of under-dosage of the cancer region or of over-dosage of healthy tissues. Monitoring techniques are currently being developed and are based on the detection of particles produced by the beam interaction into the target, in particular: charged particles, result of target and/or projectile fragmentation, prompt photons coming from nucleus de-excitation and back-to-back γ s, produced in the positron annihilation from β + emitters created in the beam interaction with the target. It has been showed that the hadron beam dose release peak can be spatially correlated with the emission pattern of these secondary particles. Here we report about secondary particles production (charged fragments and prompt γ s) performed at different beam and energies that have a particular relevance for PT applications: 12C beam of 80 MeV/u at LNS, 12C beam 220 MeV/u at GSI, and 12C, 4He, 16O beams with energy in the 50–300 MeV/u range at HIT. Finally, a project for a multimodal dose-monitor device exploiting the prompt photons and charged particles emission will be presented
    • …
    corecore