8 research outputs found

    How to implement the airborne infection isolation room in health-care settings with occupational risk for Mycobacterium tuberculosis transmission?

    Get PDF
    Universidade Federal de Minas Gerais Escola de Enfermagem Departamento de Enfermagem BásicaUniversidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de Doenças Infecciosas e ParasitáriasUNIFESP, EPM, Depto. de Doenças Infecciosas e ParasitáriasSciEL

    Reprocessing of cardiovascular angiography catheter after clinical use and artificial soil: evaluation of the efficaccy of the cleaning and sterilization.

    No full text
    A prática assistencial na área da saúde implica situações de risco, os quais podem ser maximizados, minimizados ou projetados no julgamento à luz da fundamentação científica. O reprocessamento de materiais de uso único é uma prática que, a cada dia, tem exigido esforços dos profissionais de saúde no sentido de buscar e produzir evidências que auxiliem no processo de tomada de decisão em relação à não-realização ou sob que condições podem ser executadas. O objetivo geral deste estudo foi avaliar a aplicação de diferentes processos de limpeza e a esterilização em óxido de etileno a 100% nos cateteres de angiografia cardiovascular com vista à determinação da capacidade de redução da carga microbiana e do resíduo orgânico neles antes e após a utilização pelo paciente, assim como em situações de simulação com testes desafio. Trata-se de pesquisa experimental, aplicada, comparativa e controlada realizado no Research Centre do Saint Boniface General Hospital filiado à University of Manitoba, localizada em Winnipeg no Canadá. Os cateteres foram utilizados uma única vez por pacientes submetidos a angiografia coronariana e à análise de resíduos orgânicos (hemoglobina, carboidrato, proteína e endotoxina) por meio de testes bioquímicos diretos e indiretos utilizando a técnica de espectrofotometria. A carga microbiana foi avaliada por meio da realização de cultura microbiológica por método indireto. Esses experimentos foram realizados em quatro etapas, sendo a primeira imediatamente após o uso dos cateteres para determinação da sujidade basal; a segunda, após o uso pelo paciente e limpeza do cateter por diferentes métodos; a terceira, após o uso pelo paciente, de inoculação de sujidade artificial e limpeza por diferentes métodos e a quarta, após o uso pelo paciente, teste desafio, limpeza e esterilização simulando-se cinco reusos. Foram utilizadas técnicas de estatística descritiva e analítica por meio de testes estatísticos paramétricos (análise de variância) e, quando necessário, testes não paramétricos (Kruskall-Wallis). Em todas as análises estatísticas, foram considerados testes bilaterais com um nível de significância estatística de 5% ou 0,05 e o intervalo de confiança estabelecido foi de 95%. O resultado positivo em qualquer um dos testes de detecção de resíduo orgânico e microbiológico foi indicativo de ineficácia do método de limpeza testado. As unidades amostrais foram submetidas aos seguintes métodos de limpeza: limpeza manual com detergente enzimático com enxágüe em água de torneira ou água tratada com osmose reversa e esterilizada; limpeza manual com detergente contendo peróxido de hidrogênio com enxágüe com água tratada com osmose reversa e esterilizada; limpeza automatizada com detergente enzimático sem enxágüe ou com enxágüe em água tratada com osmose reversa e esterilizada; limpeza sob pressão contínua com detergente contendo peróxido de hidrogênio com enxágüe em água de torneira ou água tratada com osmose reversa e esterilizada. Os resultados obtidos neste estudo apontam para a manutenção da carga microbiana antes e após a limpeza dos cateteres. Antes da execução de qualquer método de limpeza dos cateteres, a freqüência de culturas positivas foi de 8,2%, com uma carga microbiana média de 500UFC/unidade. Após a limpeza dos cateteres a freqüência de culturas positivas foi de 8,3% e a carga microbiana média foi de 250UFC/unidade. Os resíduos orgânicos basais detectados nos cateteres apresentavam-se nas seguintes concentrações: 146,3 µg/unidade de hemoglobina, 628,5 µg/unidade de proteína e 7,0 µg/unidade de carboidrato e 38,0 UE/unidade de endotoxina. Após a realização de cinco simulações, a concentração de hemoglobina indireta foi abaixo do limite de detecção do teste, proteína indireta =107,7 µg/unidade, carboidrato indireto= 340,1µg/unidade e endotoxina=5,4UE/unidade. A análise da concentração dos resíduos orgânicos de acordo com os métodos de limpeza demonstrou diferentes níveis de redução. Os métodos de limpeza que utilizaram o detergente contendo peróxido de hidrogênio apresentaram melhor desempenho em relação aos que utilizaram detergentes enzimáticos, sendo que o do método de limpeza sob pressão contínua foi superior aos demais métodos. Os resultados dos resíduos orgânicos dos cateteres que foram submetidos a cinco simulações de reuso mostraram-se inferiores aos valores médios absolutos de uma única simulação, com exceção da concentração média de carboidrato.The healthy assistance implies in risk, which can be maximized, minimized or projected based on the scientific data. The reprocessing of single used devices is a practice that each day has demanded efforts of the healthcare professionals in order to search and to produce scientific evidences to help them make decision in relation to not reuse or reuse under safety conditions. The objective of this study was to evaluate different cleaning processes and sterilization in ethylene oxide 100% of the angiographic catheters in order to determine the capacity in reducing of the bioburden and the organic residual before and after patient use, as well as in simulated use with soil test. It is an experimental research, comparative and controlled permed in the Research Centre of the Saint Boniface General Hospital affiliated to the University of Manitoba located in Winnipeg, Canada. The catheters had been used only one time for coronariographic exam and submitted to the analysis of organic residues (hemoglobin, carbohydrate, protein and endotoxin) by in situ and destructive test reading by spectrophotometer. The bioburden was evaluated by microbial culture. These experiments had been performed in four phases, being the first immediately after patient use to determine the basaline soil; the second after patient use and cleaning of the catheter by different methods; the third after patient use, soil test inoculation and cleaning by different methods. The fourth phase was performed after patient use and simulated reuse. Descriptive and analytical statistic analysis by parametric statistical tests (variance analysis) or no parametric tests (Kruskall-Wallis) were performed. Had been considered bilateral tests with a significance level < 0,05 and the confidence interval was 95%. It was considered clening failure of the cleaning process any positive results of the detention of organic and microbiological residue. The catheters were submitted to the following cleaning methods: manual washing with enzymatic detergent with tap water or reverse osmosis sterile rinsing; manual washing with hydrogen peroxide detergent rinsing in reverse osmosis sterile water, automated washing with no rinse or reverse osmose sterile water; hydrogen peroxide detergent pumping with tap water or reverse osmosis sterile rinsing . The results gotten in our study showed the maintenance of the bioburden before and after the cleaning of the catheters. In the baseline phase 8,2% of the cultures were positive cultures and the microbial load was 500CFU/device. After cleaning it was 8,3% and the average microbial load was 250 CFU/device. The baseline organic residues data were hemoglobin 146,3µg/device, protein 628,5 µg/device, carbohydrate 7,0µg/device and endotoxin 38,0EU/device. After five simulated use, the indirect hemoglobin concentration was lower of the test limit of detention, protein = 107,7 µg/device, carbohydrate = 340,1µg/device and endotoxin=5,4EU/device. The organic residual analysis according the cleaning methods found different levels of reduction. The cleaning methods that had used a hydrogen peroxide detergent showed better performance relating the enzymatic detergents methods, as well as hydrogen peroxide detergent pumping with reverse osmosis sterile rinsing was the best method. After simulated use phase the organic residue showed lower concentration, excepted the carbohydrate level

    Uso de furadeiras elétricas domésticas em cirurgias ortopédicas Use of domestic drilling machines in orthopedic surgeries

    No full text
    As furadeiras elétricas domésticas tem sido empregadas em cirurgias ortopédicas nos Hospitais Brasileiros, para a perfuração óssea. Entretanto, trata-se de um equipamento elétrico, termossensível, não específico para uso cirúrgico, não avaliado quanto à eficácia da esterilização e não investigada a ocorrência de infecções cirúrgicas relacionadas ao seu uso. O objetivo dessa revisão foi descrever o estado da arte do uso das furadeiras domésticas em cirurgias ortopédicas, tendo em vista as dificuldades de limpeza e esterilização do equipamento. As bases de dados LILACS e MEDLINE foram consultadas usando vocabulários controlados, livres e a combinação deles, sem restrição de tempo. Foram localizados dois artigos que abordavam o uso de furadeiras elétricas domésticas em cirurgias ortopédicas. No primeiro, o autor sugere o descarte do equipamento quando percebida a contaminação interna por sangue, considerando as dificuldades da limpeza e esterilização. O segundo artigo descreve a adaptação de uma furadeira para o uso em cirurgias, cujo método de esterilização é pastilha de formalina em condições ambientais. Estudos são necessários para avaliar a prática atual e recomendar condições seguras de uso ou o seu abandono.Domestic ordinary drilling machines have been used in orthopedic surgeries in Brazilian hospitals, for bone drilling. However, it is an electric thermo-sensitive appliance, non-specific for surgical use, not assessed in terms of sterilization efficiency, as well as on potential surgical infections associated to its use. The objective of this review was to describe the state-of-the-art use of domestic drills in orthopaedic surgeries, considering the difficulties of cleaning and sterilization. The LILACS and MEDLINE databases were consulted using MeSH and free medical terms, without time restraints. Two specific articles were found about the use of domestic electric drills in orthopaedic surgeries. In the first article, the author suggests the disposal of the equipment in cases of any noticeable blood contamination that could result in difficulties to clean it. The second article describes how to adapt a domestic drilling machine for orthopaedic surgery, but the sterilization process is performed by using formalin tablets at room conditions. Further studies are required for evaluating the current practice and to recommend safe conditions for its use or towards giving it up

    Reprocessamento de cateteres cardíacos: uma revisão

    No full text
    Os cateteres de hemodinâmica são amplamente reprocessados, principalmente em países em desenvolvimento, onde os custos da utilização desses insumos são altos. A literatura científica aponta a ausência de processos validados de limpeza e esterilização e é unânime a afirmação de que o reprocessamento provoca alterações na integridade física, química e funcional desses materiais. Dentro desse contexto, questionam-se quais as evidências publicadas sobre os danos provocados pelo reprocessamento dos cateteres de hemodinâmica? O objetivo é identificar as evidências científicas em relação aos efeitos do reprocessamento dos cateteres, do ponto de vista mecânico, físico, químico e biológico. Foi realizada uma pesquisa na base de dados Medline/Pubmed e LILACS, sem restrições de tempo, em inglês, português e espanhol, usando vocabulário controlado e não-controlado. Um total de 21 publicações foi analisado. Os artigos analisados apontam a ocorrência de alterações físicas, mecânicas e químicas. A limpeza e a esterilização dos cateteres não foi eficiente, tendo sido identificada a presença de debris e microrganismos ao final do processo. Vale ressaltar a importância dessas informações para a tomada de decisão em relação ao reprocessamento e reuso de cateteres de hemodinâmica
    corecore