63 research outputs found

    Advantages of subclavian artery perfusion for repair of acute type A dissection

    Get PDF
    Objective: Arterial perfusion through the right subclavian artery is proposed to avoid intraoperative malperfusion during repair of acute type A dissection. This study evaluated the clinical and neurological outcome of patients undergoing surgery of acute aortic type A dissection following subclavian arterial cannulation compared to femoral artery approach. Methods: From 1/97 to 1/03, 122 consecutive patients underwent surgery for acute type A aortic dissection. Subclavian cannulation was performed in 62 versus femoral cannulation in 60 patients. Clinical characteristics in both groups were similar. Mean age was 61 years (SD±14 years, 72% male) and mean follow-up was 3 years (±2 years). Patient outcome was assessed as the prevalence of clinical complications, especially neurological deficits, mortality at 30 days, perioperative morbidity and time of body temperature cooling and analyzed by nominal logistic regression analysis for odds ratio calculation. Results: Arterial subclavian cannulation was successfully performed without any occurrence of malperfusion in all cases. Patients undergoing subclavian cannulation showed an odds ratio of 1.98 (95% CI 1.15-3.51; P=0.0057) for an improved neurological outcome compared to patients undergoing femoral cannulation. Re-exploration rate for postoperative bleeding was significantly reduced in the subclavian group (P<0.0001), as well as occurrence of myocardial infarction (P<0.0001) and duration for body temperature cooling (P=0.004). The 30-day mortality of patients with femoral cannulation was significantly higher compared to patients with subclavian artery cannulation (24 versus 8%; P=0.0179). Conclusions: Arterial perfusion through the right subclavian artery provides an excellent approach for repair of acute type A dissection with optimized arterial perfusion body perfusion and allows for antegrade cerebral perfusion during circulatory arrest. The technique is safe and results in a significantly improved clinical and especially neurological outcom

    Humanoids for teaching and training coronary artery bypass surgery to the next generation of cardiac surgeons

    Full text link
    Objectives: Technical skills are an essential component of cardiac surgery, and the operating room is becoming an even more challenging environment for trainees who want to acquire such skills. Simulation, which partially overcomes this limitation, represents a valid adjunct to surgical education. We describe an original simulator and provide results in terms of trainees' evaluations and ratings. Methods: We used a humanoid that is a silicone replica of the chest of an adult human that provides a complete anatomical platform for hands-on skin-to-skin practice of surgical techniques in arrested heart coronary artery bypass graft (CABG) surgery cases. Learners were residents in cardiac surgery. The teaching sessions included 2 full three-vessel CABG procedures using both mammary arteries and a hydrogel vein. Five board-certified cardiovascular surgeons scored the surgical activity of all trainees. The trainees were asked to complete an exit questionnaire to evaluate their course. Results: Overall, 16 residents participated in the simulation, including 5 women and 11 men, with a mean age of 30 ± 4 years, all of whom had at least 2 years of cardiac surgery training. All participants completed the 2 CABG operations. Three mammary arteries (4.6%) were seriously damaged during harvesting. In 1 case (3.1%), an aortic tear occurred during aortic cannulation. Each trainee performed overall 6 distal and 2 proximal coronary anastomoses. All participants agreed that the 'humanoid reproduces real-life situations, the feeling is realistic, and they are now more confident in performing coronary anastomosis'. Conclusions: Trainees involved in this simulation curriculum acquired and refined technical skills that could be applied directly to human patients. In addition, we were able to foster a higher level of teamwork within the operating room team. Keywords: Coronary artery bypass grafting; Surgical simulator; Trainin

    Early silent coronary bypass graft occlusion following coronary bypass surgery, implication of routine coronary computed tomography angiography

    Get PDF
    ObjectiveTo evaluate incidence and predictors of early silent bypass occlusion following coronary bypass surgery using cardiac computed tomography angiography.MethodsA total of 439 consecutive patients with mean age of 66 ± 10 years comprising 17% (n = 75) females underwent isolated coronary bypass surgery followed by CT scan before discharge. Graft patency was evaluated in 1,319 anastomoses where 44% (n = 580) arterial and 56% (n = 739) vein graft anastomosis were performed. Cardiovascular risk factors, demographics, and intraoperative variables were analyzed. We conducted univariable and multivariable logistic regression analyses to analyze variables potentially associated with graft occlusion following CABG. Variables included gender, surgery duration, graft flow, pulsatility index, vein vs. artery graft, and recent MI.ResultsOverall incidence of graft occlusion was 2.4% (31/1,319), and it was diagnosed in 6.6% (29/439) of patients. The difference in occlusion between arterial (2.1%) and vein (2.6%) grafts was not significant, p = 0.68. The duration of intervention p = 0.034, cross clamp time p = 0.024 as well the number of distal anastomosis p = 0.034 were significantly higher in occlusion group. The univariate and multivariate logistic regression indicated duration of surgery being predictive for bypass graft occlusion with OR = 1.18; 95% CI: 1.01–1.38; p = 0.035.ConclusionsEarly graft occlusion was associated with surgical factors. The number of distant anastamoses, along duration of surgical intervention were, significantly influenced the risk of EGO. Prolonged procedural time reflecting complex coronary pathology and time-consuming revascularization procedure was as well associated to the elevated risk of occlusion

    Lower diagnostic accuracy of hs-cTnI in patients with prior coronary artery bypass grafting

    Get PDF
    High-sensitivity cardiac troponin T (hs-cTnT) and the ESC 0/1h-hs-cTnT-algorithm have worse performance in the early diagnosis of myocardial infarction (MI) in patients with prior coronary artery bypass grafting (CABG). It is unknown, whether this concern applies also to hs-cTnI, the most widely used analyte worldwide.; In an international multicenter diagnostic study, two cardiologists centrally adjudicated the final diagnosis in patients presenting to the emergency department with symptoms suggestive of MI according to the Third Universal Definition of MI. The objective was to compare the diagnostic accuracy of hs-cTnI assays and their performance within the ESC hs-cTnI 0/1h-algorithms in patients with versus without prior CABG. Findings were externally validated in an U.S. multicenter diagnostic study.; A total of 392/5'200 patients (8%) had prior coronary artery bypass grafting (CABG). Diagnostic accuracy of hs-cTnI as quantified by the area under the receiver-operating characteristics-curve (AUC) in these patients was high, but lower versus patients without prior CABG (e.g. hs-cTnI-Architect 0.91 versus 0.95; p = 0.016). Sensitivity/specificity of rule-out/in by the European Society of Cardiology (ESC) 0/1h-hs-cTnI-algorithms remained very high [e.g. hs-cTnI-Architect 100% and 93.5%], but efficacy was lower (52% versus 74%, p < 0.01). External validation (n = 2113) confirmed these findings in 192 patients with prior CABG using hs-cTnI-Atellica, with 52% versus 36% (p < 0.001) remaining in the observe zone.; Diagnostic accuracy of hs-cTnI and efficacy of the ESC 0/1h-hs-cTnI-algorithms are lower in patients with prior CABG, but sensitivity/specificity remain very high.; https://clinicaltrials.gov/ct2/show/NCT00470587, number NCT00470587

    Pilot licensing after aortic valve surgery.

    No full text
    Background and aim of the study: Bicuspid aortic valve is the most common congenital heart malformation, and a high percentage of patients with this condition will develop complications over time. It is rare that pilots undergo aortic valve surgery, and the confirmation of flight-licensing requirements after aortic valve replacement (AVR) is a challenge for the patient's cardiac surgeon and, particularly, for the Aeromedical Examiner (AME). Only AMEs are able to determine the flight status of pilots. Furthermore, in military and in civil aviation (e.g., Red Bull Air Race), the high G-load environment experienced by pilots is an exceptional physiological parameter, which must be considered postoperatively. Methods: A review was conducted of the aeronautical, surgical and medical literature, and of European pilot-licensing regulations. Case studies are also reported for two Swiss Air Force pilots. Results: According to European legislation, pilots can return to flight duty from the sixth postoperative month, with the following limitations: that an aortic bioprosthesis presents no restrictions in cardiac function, requires no cardioactive medications, yet requires a flight operation with co-pilot, the avoidance of accelerations over +3 Gz and, in military aviation, restricts the pilot to non-ejection-seat aircraft. The patient follow up must include both echocardiographic and rhythm assessments every six months. Mechanical prostheses cannot be certified because the required anticoagulation therapy is a disqualifying condition for pilot licensing. Conclusion: Pilot licensing after aortic valve surgery is possible, but with restrictions. The +Gz exposition is of concern in both military and civilian aviation (aerobatics). The choice of bioprosthesis type and size is determinant. Pericardial and stentless valves seem to show better flow characteristics under high-output conditions. Repetitive cardiological controls are mandatory for the early assessment of structural valve disease and rhythm disturbances. A pre-emptive timing is recommended when reoperation is indicated, without waiting for clinical manifestations of structural valve disease

    Detrimental consequences after intimal disruption of subclavian artery during transcathether aortic valve implantation

    No full text
    Abstract Background TAVI via the left subclavian artery is considered a bail-out strategy in cases where a transfemoral approach is not feasible. However, since this route is only scarcely used, major complications can arise. We describe such an adverse course and present our proceeding. Case presentation A 65-year-old man with severe aortic valve stenosis (AS) was referred for transcatheter aortic valve implantation (TAVI) via left subclavian artery. After uneventful deployment of the TAVI prosthesis, consequent valve assessment with transeosophageal echocardiography and angiography showed a highly mobile and tubular structure shifting within the valve. We went for a surgical extraction via sternotomy on cardiopulmonary bypass (CPB). A 6 cm longish intimal cylinder was hassle-free extracted. 4 days postoperatively the left sided radial pulse was missing. In a subsequent computed tomography angiography (CTA) scan a proximal dissection as well as an intimal flap, causing a subtotal stenosis of the left subclavian artery, was detected. Consecutively the intimal cylinder was removed using a Fogarty-balloon. Pre-discharge control revealed recurrence of peripheral radial pulse and an unimpeded function of the TAVI prosthesis. The patient presented no sequela at discharge. Conclusion Though TAVI is a well-advanced technique complications are not completely avertable. It is thus advisable to have patients discussed in the heart team encompassing all potentially involved specialties

    Unexpected collateral impact after out of hospital resuscitation using LUCAS system

    No full text
    Abstract Background Mechanical chest compression using a piston device during reanimation is often the only way to ensure stable chest compression at a constant rate and force. However, its use can be associated with severe fractures of the thoracic rib cage and endanger the clinical course of the patient. Thus, the usage of such a piston device during the reanimation has currently been classified as a mere Class IIB indication. Case presentation We present a case of a 66-year-old male who underwent emergent CABG surgery after receiving out-of-hospital resuscitation as a result of myocardial infarction using the LUCAS system. Due to severe bilateral rib fractures a concomitant emergency chest-wall stabilization surgery had to be performed to ensure uncompromised graft flow to obtain stable cardiac function and hemodynamics. Conclusions Reanimation using LUCAS-System might enable stable resuscitation conditions. However, it is crucial not to underestimate potential collateral damage which can in turn aggravate patient’s clinical condition

    Transapical Transcatheter Mitral Valve Implantation with the Tendyne Valve: The Swiss Experience.

    No full text
    BACKGROUND  The aim of this study was to report outcomes of all patients undergoing transcatheter mitral valve implantation with the Tendyne Mitral Valve System (Tendyne) in Switzerland. METHODS  We retrospectively analyzed preoperative echocardiographic and computed tomography (CT) data, procedural findings, and 30-day and 1-year follow-up echocardiographic and clinical data of patients who underwent transcatheter mitral valve implantation with Tendyne in Switzerland. RESULTS  A total of 24 patients (age, 74.8 ± 7.8 years; 67% male) underwent transapical transcatheter mitral valve implantation with Tendyne between June 2020 and October 2022. Technical success rate was 96%. In five patients, concomitant interventions in the form of transcatheter aortic valve implantation (one patient), minimally invasive direct coronary artery bypass (one patient), and transcatheter edge-to-edge repair (three patients) were performed prior to or after the index procedure. There was one device embolization, and two patients required valve retrieval. In-hospital outcomes included one stroke and three major bleeding events. None of the patients died within 30 days. Two patients were rehospitalized for decompensated heart failure. At 1-year follow-up, there were three noncardiovascular-related deaths. CONCLUSION  Transcatheter mitral valve implantation with Tendyne is feasible to treat polymorbid patients suffering from complex mitral valve disease as well as patients with previous mitral interventions. Perioperative risk was acceptable and procedural success high

    A new cable-tie based sternal closure system: description of the device, technique of implantation and first clinical evaluation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Wire closure still remains the preferred technique despite reasonable disadvantages. Associated complications, such as infection and sternal instability, cause time- and cost-consuming therapies. We present a new tool for sternal closure with its first clinical experience and results.</p> <p>Methods</p> <p>The sternal ZipFix<sup>TM</sup> System is based on the cable-tie principle. It primarily consists of biocompatible Poly-Ether-Ether-Ketone implants and is predominantly used peristernally through the intercostal space. The system provides a large implant-to-bone contact for better force distribution and for avoiding bone cut through.</p> <p>Results</p> <p>50 patients were closed with the ZipFix<sup>TM</sup> system. No sternal instability was observed at 30 days. Two patients developed a mediastinitis that necessitated the removal of the device; however, the ZipFix<sup>TM</sup> were intact and the sternum remained stable.</p> <p>Conclusions</p> <p>In our initial evaluation, the short-term results have shown that the sternal ZipFix<sup>TM</sup> can be used safely and effectively. It is fast, easy to use and serves as a potential alternative for traditional wire closure.</p
    • 

    corecore