168 research outputs found
Recommended from our members
First quarter Hanford seismic report for fiscal year 2000
Hanford Seismic Monitoring provides an uninterrupted collection of high-quality raw and processed seismic data from the Hanford Seismic Network (HSN) for the US Department of Energy and its contractors. Hanford Seismic Monitoring also locates and identifies sources of seismic activity and monitors changes in the historical pattern of seismic activity at the Hanford Site. The data are compiled, archived, and published for use by the Hanford Site for waste management, Natural Phenomena Hazards assessments, and engineering design and construction. In addition, the seismic monitoring organization works with the Hanford Site Emergency Services Organization to provide assistance in the event of a significant earthquake on the Hanford Site. The HSN and the Eastern Washington Regional Network (EWRN) consist of 42 individual sensor sites and 15 radio relay sites maintained by the Hanford Seismic Monitoring staff. The HSN uses 21 sites and the EW uses 36 sites; both networks share 16 sites. The networks have 46 combined data channels because Gable Butte and Frenchman Hills East are three-component sites. The reconfiguration of the telemetry and recording systems was completed during the first quarter. All leased telephone lines have been eliminated and radio telemetry is now used exclusively. For the HSN, there were 311 triggers on two parallel detection and recording systems during the first quarter of fiscal year (FY) 2000. Twelve seismic events were located by the Hanford Seismic Network within the reporting region of 46--47{degree}N latitude and 119--120{degree}W longitude; 2 were earthquakes in the Columbia River Basalt Group, 3 were earthquakes in the pre-basalt sediments, 9 were earthquakes in the crystalline basement, and 1 was a quarry blast. Two earthquakes appear to be related to a major geologic structure, no earthquakes occurred in known swarm areas, and 9 earthquakes were random occurrences. No earthquakes triggered the Hanford Strong Motion Accelerometers during the first quarter of FY 2000
Precision of the PET activity range during irradiation with <sup>10</sup>C, <sup>11</sup>C, and <sup>12</sup>C beams
Objective. Beams of stable ions have been a well-established tool for radiotherapy for many decades. In the case of ion beam therapy with stable 12C ions, the positron emitters 10,11C are produced via projectile and target fragmentation, and their decays enable visualization of the beam via positron emission tomography (PET). However, the PET activity peak matches the Bragg peak only roughly and PET counting statistics is low. These issues can be mitigated by using a short-lived positron emitter as a therapeutic beam. Approach. An experiment studying the precision of the measurement of ranges of positron-emitting carbon isotopes by means of PET has been performed at the FRS fragment-separator facility of GSI Helmholtzzentrum für Schwerionenforschung GmbH, Germany. The PET scanner used in the experiment is a dual-panel version of a Siemens Biograph mCT PET scanner. Main results. High-quality in-beam PET images and activity distributions have been measured from the in-flight produced positron emitting isotopes 11C and 10C implanted into homogeneous PMMA phantoms. Taking advantage of the high statistics obtained in this experiment, we investigated the time evolution of the uncertainty of the range determined by means of PET during the course of irradiation, and show that the uncertainty improves with the inverse square root of the number of PET counts. The uncertainty is thus fully determined by the PET counting statistics. During the delivery of 1.6 × 107 ions in 4 spills for a total duration of 19.2 s, the PET activity range uncertainty for 10C, 11C and 12C is 0.04 mm, 0.7 mm and 1.3 mm, respectively. The gain in precision related to the PET counting statistics is thus much larger when going from 11C to 10C than when going from 12C to 11C. The much better precision for 10C is due to its much shorter half-life, which, contrary to the case of 11C, also enables to include the in-spill data in the image formation. Significance. Our results can be used to estimate the contribution from PET counting statistics to the precision of range determination in a particular carbon therapy situation, taking into account the irradiation scenario, the required dose and the PET scanner characteristics.</p
Recommended from our members
Draft low level waste technical summary
The purpose of this document is to present an outline of the Hanford Site Low-Level Waste (LLW) disposal program, what it has accomplished, what is being done, and where the program is headed. This document may be used to provide background information to personnel new to the LLW management/disposal field and to those individuals needing more information or background on an area in LLW for which they are not familiar. This document should be appropriate for outside groups that may want to learn about the program without immediately becoming immersed in the details. This document is not a program or systems engineering baseline report, and personnel should refer to more current baseline documentation for critical information
Postsurgical pain outcome of vertical and transverse abdominal incision: Design of a randomized controlled equivalence trial [ISRCTN60734227]
BACKGROUND: There are two ways to open the abdominal cavity in elective general surgery: vertically or transversely. Various clinical studies and a meta-analysis have postulated that the transverse approach is superior to other approaches as regards complications. However, in a recent survey it was shown that 90 % of all abdominal incisions in visceral surgery are still vertical incisions. This discrepancy between existing recommendations of clinical trials and clinical practice could be explained by the lack of acceptance of these results due to a number of deficits in the study design and analysis, subsequent low internal validity, and therefore limited external generalisability. The objective of this study is to address the issue from the patient's perspective. METHODS: This is an intraoperatively randomized controlled observer and patient-blinded two-group parallel equivalence trial. The study setting is the Department of General-, Visceral-, Trauma Surgery and Outpatient Clinic of the University of Heidelberg, Medical School. A total of 172 patients of both genders, aged over 18 years who are scheduled for an elective abdominal operation and are eligible for either a transverse or vertical incision. To show equivalence of the two approaches or the superiority of one of them from the perspective of the patient, a primary endpoint is defined: the pain experienced by the patient (VAS 0–100) on day two after surgery and the amount of analgesic required (piritramide [mg/h]). A confidence interval approach will be used for analysis. A global α-Level of 0.05 and a power of 0.8 is guaranteed, resulting in a size of 86 patients for each group. Secondary endpoints are: time interval to open and close the abdomen, early-onset complications (frequency of burst abdomen, postoperative pulmonary complications, and wound infection) and late complications (frequency of incisional hernias). Different outcome variables will be ranked by patients and surgeons to assess the relevance of possible endpoints from the patients' and surgeons' perspective. CONCLUSION: This is a randomized controlled observer and patient-blinded two-group parallel trial to answer the question if the transverse abdominal incision is equivalent to the vertical one due to the described endpoints
Elemental fragmentation cross sections for a O-16 beam of 400 MeV/u kinetic energy interacting with a graphite target using the FOOT Delta E-TOF detectors
The study of nuclear fragmentation plays a central role in many important applications: from the study of Particle Therapy (PT) up to radiation protection for space (RPS) missions and the design of shielding for nuclear reactors. The FragmentatiOn Of Target (FOOT) collaboration aims to study the nuclear reactions that describe the interactions with matter of different light ions (like H-1, He-4, C-12, O-16) of interest for such applications, performing double differential fragmentation cross section measurements in the energy range of interest for PT and RPS. In this manuscript, we present the analysis of the data collected in the interactions of an oxygen ion beam of 400 MeV/u with a graphite target using a partial FOOT setup, at the GSI Helmholtz Center for Heavy Ion Research facility in Darmstadt. During the data taking the magnets, the silicon trackers and the calorimeter foreseen in the final FOOT setup were not yet available, and hence precise measurements of the fragments kinetic energy, momentum and mass were not possible. However, using the FOOT scintillator detectors for the time of flight (TOF) and energy loss (Delta E) measurements together with a drift chamber, used as beam monitor, it was possible to measure the elemental fragmentation cross sections. The reduced detector set-up and the limited available statistics allowed anyway to obtain relevant results, providing statistically significant measurements of cross sections eagerly needed for PT and RPS applications. Whenever possible the obtained results have been compared with existing measurements helping in discriminating between conflicting results in the literature and demonstrating at the same time the proper functioning of the FOOT Delta E-TOF system. Finally, the obtained fragmentation cross sections are compared to the Monte Carlo predictions obtained with the FLUKA software
Organotypic Culture of Physiologically Functional Adult Mammalian Retinas
BACKGROUND: The adult mammalian retina is an important model in research on the central nervous system. Many experiments require the combined use of genetic manipulation, imaging, and electrophysiological recording, which make it desirable to use an in vitro preparation. Unfortunately, the tissue culture of the adult mammalian retina is difficult, mainly because of the high energy consumption of photoreceptors. METHODS AND FINDINGS: We describe an interphase culture system for adult mammalian retina that allows for the expression of genes delivered to retinal neurons by particle-mediated transfer. The retinas retain their morphology and function for up to six days— long enough for the expression of many genes of interest—so that effects upon responses to light and receptive fields could be measured by patch recording or multielectrode array recording. We show that a variety of genes encoding pre- and post-synaptic marker proteins are localized correctly in ganglion and amacrine cells. CONCLUSIONS: In this system the effects on neuronal function of one or several introduced exogenous genes can be studied within intact neural circuitry of adult mammalian retina. This system is flexible enough to be compatible with genetic manipulation, imaging, cell transfection, pharmacological assay, and electrophysiological recordings
Precision of the PET activity range during irradiation with ¹⁰C, ¹¹C, and ¹²C beams
Objective. Beams of stable ions have been a well-established tool for radiotherapy for many decades. In the case of ion beam therapy with stable ¹²C ions, the positron emitters ¹⁰,¹¹C are produced via projectile and target fragmentation, and their decays enable visualization of the beam via positron emission tomography (PET). However, the PET activity peak matches the Bragg peak only roughly and PET counting statistics is low. These issues can be mitigated by using a short-lived positron emitter as a therapeutic beam. Approach. An experiment studying the precision of the measurement of ranges of positron-emitting carbon isotopes by means of PET has been performed at the FRS fragment-separator facility of GSI Helmholtzzentrum für Schwerionenforschung GmbH, Germany. The PET scanner used in the experiment is a dual-panel version of a Siemens Biograph mCT PET scanner. Main results. High-quality in-beam PET images and activity distributions have been measured from the in-flight produced positron emitting isotopes ¹¹C and ¹⁰C implanted into homogeneous PMMA phantoms. Taking advantage of the high statistics obtained in this experiment, we investigated the time evolution of the uncertainty of the range determined by means of PET during the course of irradiation, and show that the uncertainty improves with the inverse square root of the number of PET counts. The uncertainty is thus fully determined by the PET counting statistics. During the delivery of 1.6 × 10⁷ ions in 4 spills for a total duration of 19.2 s, the PET activity range uncertainty for ¹⁰C, ¹¹C and ¹²C is 0.04 mm, 0.7 mm and 1.3 mm, respectively. The gain in precision related to the PET counting statistics is thus much larger when going from ¹¹C to ¹⁰C than when going from ¹²C to ¹¹C. The much better precision for ¹⁰C is due to its much shorter half-life, which, contrary to the case of ¹¹C, also enables to include the in-spill data in the image formation. Significance. Our results can be used to estimate the contribution from PET counting statistics to the precision of range determination in a particular carbon therapy situation, taking into account the irradiation scenario, the required dose and the PET scanner characteristics
Affective processes as network hubs
The practical problems of designing and coding a web-based flight simulator for teachers has led to a ‘three-tier plus environment’ model (COVE model) for a software agent’s cognition (C), psychologicsal (O), physical (V) processes and responses to tasks and interpersonal relationships within a learning environment (E). The purpose of this article is to introduce how some of the COVE model layers represent preconscious processing hubs in an AI human-agent’s representation of learning in a serious game, and how an application of the Five Factor Model of psychology in the O layer determines the scope of dimensions for a practical computational model of affective processes. The article illustrates the model with the classroom-learning context of the simSchool application (www.simschool.org); presents details of the COVE model of an agent’s reactions to academic tasks; discusses the theoretical foundations; and outlines the research-based real world impacts from external validation studies as well as new testable hypotheses of simSchool
Seroprevalence of 34 Human Papillomavirus Types in the German General Population
The natural history of infections with many human papillomavirus (HPV) types is poorly understood. Here, we describe for the first time the age- and sex-dependent antibody prevalence for 29 cutaneous and five mucosal HPV types from 15 species within five phylogenetic genera (alpha, beta, gamma, mu, nu) in a general population. Sera from 1,797 German adults and children (758 males and 1,039 females) between 1 and 82 years (median 37 years) were analysed for antibodies to the major capsid protein L1 by Luminex-based multiplex serology. The first substantial HPV antibody reactions observed already in children and young adults are those to cutaneous types of the genera nu (HPV 41) and mu (HPV 1, 63). The antibody prevalence to mucosal high-risk types, most prominently HPV 16, was elevated after puberty in women but not in men and peaked between 25 and 34 years. Antibodies to beta and gamma papillomaviruses (PV) were rare in children and increased homogeneously with age, with prevalence peaks at 40 and 60 years in women and 50 and 70 years in men. Antibodies to cutaneous alpha PV showed a heterogeneous age distribution. In summary, these data suggest three major seroprevalence patterns for HPV of phylogenetically distinct genera: antibodies to mu and nu skin PV appear early in life, those to mucosal alpha PV in women after puberty, and antibodies to beta as well as to gamma skin PV accumulate later in life
- …