1,081 research outputs found

    Robust phase unwrapping based on non-coprime fringe pattern periods for deflectometry measurements

    Get PDF
    Phase-measuring deflectometry is a technique for non-contact inspection of reflective surfaces. A camera setup captures the reflection of a sine-modulated fringe pattern shifted across a screen; the location-dependent measured phase effectively encodes the screen coordinates. As the used fringe patterns are much narrower than the screen dimension, the resulting phase maps are wrapped. The number-theoretical solution uses the Chinese remainder theorem to calculate an unwrapped phase map from repeated measurements with coprime fringe widths. The technique is highly susceptible to phase noise, i.e. small deviations of the measured phase values generally lead to unwrapped phase values with large errors. We propose a modification and show how non-coprime period widths make phase unwrapping robust against phase noise. Measurements with two non-coprime fringe period widths introduce the opportunity to discriminate between “legal” measured phase value pairs, that potentially originate from noise-free measurements, and “illegal” phase value pairs, that necessarily result from noise-affected measurements. Arranged as a matrix, the legal measurements lie on distinct diagonals. This insight not only allows to determine the legality of a measurement, but also to provide a correction by looking for the closest legal matrix entry. We present an experimental comparison of the resulting phase maps with reference phase maps. The presented results include descriptive statistics on the average rate of illegal phase measurements as well as on the deviation from the reference. The measured mean absolute deviation decreases from 1.99 pixels before correction to 0.21 pixels after correction, with a remaining maximum absolute deviation of 0.91 pixels

    The effects of pattern screen surface deformation on deflectometric measurements - A simulation study

    Get PDF
    Phase-measuring deflectometry (PMD) is an optical inspection technique for full-field topography measurements of reflective sample surfaces. The measurement principle relies on the analysis of specific patterns, reflected at the sample surface. Evaluation algorithms often model the respective pattern screen as a planar light source. However, the 32\u27\u27 pattern screen in our inspection setup exhibits a central bulge of its surface of about 2–3 mm. This paper presents a simulation framework for PMD to evaluate the effects of a deformed screen surface. The idea is to simulate image data acquired with screen surface deformations and to examine the effects on the PMD evaluation results. The simulated setup consists of a 32\u27\u27 pattern screen with an adjustable central bulge height of 0–3 mm and two cameras with a field of view (FOV) of approximately 225 mm by 172 mm on the sample surface. A first experiment examines the reconstruction errors for a planar sample surface if the reconstruction algorithm uses perfect calibration data (i.e. the same parameters used for the simulated image acquisition). The reconstructed surfaces exhibit a tilt with a maximum height difference of 174 μm across the FOV. A second experiment repeats the reconstruction process of the same sample surface, using camera parameters determined in a simulated calibration process. The resulting surfaces possess irregular, wave-like errors with amplitudes of up to 9 μm in the FOV. The presented simulation results reveal the accuracy limits if a deformation model of the pattern screen is not explicitly included in the reconstruction process

    Reproducibility of two calibration procedures for phase-measuring deflectometry

    Get PDF
    Phase-measuring deflectometry is an optical inspection technique for reflective surfaces. It enables absolute, quantitative surface measurements, given a calibrated measurement setup. Two general calibration approaches can be found in literature: First, the stepwise approach uses a calibration pattern and determines internal camera parameters and external geometrical parameters in separate, consecutive steps. Second, the holistic approach optimizes all parameters collectively, based on deflectometric measurements of a calibration mirror. Whereas both approaches have been compared regarding the accuracy of subsequent surface measurements, the present contribution focuses on experimental examination of their reproducibility. In experiment E1, we assess the parameter variability by repeating both calibration procedures ten times. In an additional experiment E2, we repeat all calibration measurements related to a mirror/pattern position ten times in a row before rearranging the mirror/pattern, in order to examine the purely noise-related parameter variability. Finally, we calculate the coordinate variability of a set of world points projected onto the image planes of the calibrated cameras. The measured variability is consistently higher in E1 than in E2 (average ratio: 3.2). Unexpectedly, in both experiments, the external parameter variability also turns out to be higher for the holistic approach compared to stepwise calibration (average ratio: 2.3). This is of importance, since the holistic approach is known from literature to be more accurate than the stepwise approach, regarding their respective application to surface measurements. The image coordinate variability is comparable for both calibration approaches with an average of 0.84 and 0.21 camera pixels for E1 and E2, respectively

    A reproducible extrusion printing process with highly viscous nanoparticle inks

    Get PDF
    Printing of functional materials such as nanoparticle inks is a class of additive fabrication techniques complementary to standard subtractive electronics fabrication techniques such as pcb technology on pcb level or silicon based microelectronics on integrated circuit level. To date the majority of digital printing processes for (micro)electronics is inkjet based. Moreover aerosol jet based printing also establishes itself for printing on non-planar substrates and for materials with higher viscosities. A material deposition technique available since decades and mainly used for dispensing of adhesives and sealing materials is fluid-filament printing. It allows to cover a wide range of materials and viscosities and thus, also holds potential for additive manufacturing of electronics. In this paper we systematically study the influences on fluid filament printing both theoretically taking into account ink and equipment tolerances and experimentally using mainly standard dispensing equipment and two commercial screen printing inks. At the end of the paper we derive recommendations for reproducible printing of conductive lines and pads and give an outlook to printing 2.5D structures

    Systematic Investigation of Novel, Controlled Low‐Temperature Sintering Processes for Inkjet Printed Silver Nanoparticle Ink

    Get PDF
    Functional inks enable manufacturing of flexible electronic devices by means of printing technology. Silver nanoparticle (Ag NP) ink is widely used for printing conductive components. A sintering process is required to obtain sufficient conductivity. Thermal sintering is the most commonly used method, but the heat must be carefully applied to avoid damaging low-temperature substrates such as polymer films. In this work, two alternative sintering methods, damp heat sintering and water sintering are systematically investigated for inkjet-printed Ag tracks on polymer substrates. Both methods allow sintering polyvinyl pyrrolidone (PVP) capped Ag NPs at 85°C. In this way, the resistance is significantly reduced to only 1.7 times that of the samples on polyimide sintered in an oven at 250°C. The microstructure of sintered Ag NPs is analyzed. Taking the states of the capping layer under different conditions into account, the explanation of the sintering mechanism of Ag NPs at low temperatures is presented. Overall, both damp heat sintering and water sintering are viable options for achieving high conductivity of printed Ag tracks. They can broaden the range of substrates available for flexible electronic device fabrication while mitigating substrate damage risks. The choice between them depends on the specific application and the substrate used

    3D confocal laser-scanning microscopy for large-area imaging of the corneal subbasal nerve plexus

    Get PDF
    The capability of corneal confocal microscopy (CCM) to acquire high-resolution in vivo images of the densely innervated human cornea has gained considerable interest in using this non-invasive technique as an objective diagnostic tool for staging peripheral neuropathies. Morphological alterations of the corneal subbasal nerve plexus (SNP) assessed by CCM have been shown to correlate well with the progression of neuropathic diseases and even predict future-incident neuropathy. Since the field of view of single CCM images is insufficient for reliable characterisation of nerve morphology, several image mosaicking techniques have been developed to facilitate the assessment of the SNP in large-area visualisations. Due to the limited depth of field of confocal microscopy, these approaches are highly sensitive to small deviations of the focus plane from the SNP layer. Our contribution proposes a new automated solution, combining guided eye movements for rapid expansion of the acquired SNP area and axial focus plane oscillations to guarantee complete imaging of the SNP. We present results of a feasibility study using the proposed setup to evaluate different oscillation settings. By comparing different image selection approaches, we show that automatic tissue classification algorithms are essential to create high-quality mosaic images from the acquired 3D dataset

    Taxane-Induced Neuropathy and Its Ocular Effects—A Longitudinal Follow-up Study in Breast Cancer Patients

    Get PDF
    A common severe neurotoxic side effect of breast cancer (BC) therapy is chemotherapy-induced peripheral neuropathy (CIPN) and intervention is highly needed for the detection, prevention, and treatment of CIPN at an early stage. As the eye is susceptible to neurotoxic stimuli, the present study aims to determine whether CIPN signs in paclitaxel-treated BC patients correlate with ocular changes by applying advanced non-invasive biophotonic in vivo imaging. Patients (n = 14, 10 controls) underwent monitoring sessions after diagnosis, during, and after therapy (T0-T3). Monitoring sessions included general anamnesis, assessment of their quality of life, neurological scores, ophthalmological status, macular optical coherence tomography (OCT), and imaging of their subbasal nerve plexus (SNP) by large-area confocal laser-scanning microscopy (CLSM). At T0, no significant differences were detected between patients and controls. During treatment, patients’ scores significantly changed while the greatest differences were found between T0 and T3. None of the patients developed severe CIPN but retinal thickenings could be detected. CLSM revealed large SNP mosaics with identical areas while corneal nerves remained stable. The study represents the first longitudinal study combining oncological examinations with advanced biophotonic imaging techniques, demonstrating a powerful tool for the objective assessment of the severity of neurotoxic events with ocular structures acting as potential biomarkers

    Real-time large-area imaging of the corneal subbasal nerve plexus

    Get PDF
    The morphometric assessment of the corneal subbasal nerve plexus (SNP) by confocal microscopy holds great potential as a sensitive biomarker for various ocular and systemic conditions and diseases. Automated wide-field montages (or large-area mosaic images) of the SNP provide an opportunity to overcome the limited field of view of the available imaging systems without the need for manual, subjective image selection for morphometric characterization. However, current wide-field montaging solutions usually calculate the mosaic image after the examination session, without a reliable means for the clinician to predict or estimate the resulting mosaic image quality during the examination. This contribution describes a novel approach for a real-time creation and visualization of a mosaic image of the SNP that facilitates an informed evaluation of the quality of the acquired image data immediately at the time of recording. In cases of insufficient data quality, the examination can be aborted and repeated immediately, while the patient is still at the microscope. Online mosaicking also offers the chance to identify an overlap of the imaged tissue region with previous SNP mosaic images, which can be particularly advantageous for follow-up examinations
    corecore