1,230 research outputs found

    Development of Aluminum LEKIDs for Balloon-Borne Far-IR Spectroscopy

    Get PDF
    We are developing lumped-element kinetic inductance detectors (LEKIDs) designed to achieve background-limited sensitivity for far-infrared (FIR) spectroscopy on a stratospheric balloon. The Spectroscopic Terahertz Airborne Receiver for Far-InfraRed Exploration (STARFIRE) will study the evolution of dusty galaxies with observations of the [CII] 158 μ\mum and other atomic fine-structure transitions at z=0.51.5z=0.5-1.5, both through direct observations of individual luminous infrared galaxies, and in blind surveys using the technique of line intensity mapping. The spectrometer will require large format (\sim1800 detectors) arrays of dual-polarization sensitive detectors with NEPs of 1×10171 \times 10^{-17} W Hz1/2^{-1/2}. The low-volume LEKIDs are fabricated with a single layer of aluminum (20 nm thick) deposited on a crystalline silicon wafer, with resonance frequencies of 100250100-250 MHz. The inductor is a single meander with a linewidth of 0.4 μ\mum, patterned in a grid to absorb optical power in both polarizations. The meander is coupled to a circular waveguide, fed by a conical feedhorn. Initial testing of a small array prototype has demonstrated good yield, and a median NEP of 4×10184 \times 10^{-18} W Hz1/2^{-1/2}.Comment: accepted for publication in Journal of Low Temperature Physic

    Actin crosslinker competition and sorting drive emergent GUV size-dependent actin network architecture

    Get PDF
    The proteins that make up the actin cytoskeleton can self-assemble into a variety of structures. In vitro experiments and coarse-grained simulations have shown that the actin crosslinking proteins α-actinin and fascin segregate into distinct domains in single actin bundles with a molecular size-dependent competition-based mechanism. Here, by encapsulating actin, α-actinin, and fascin in giant unilamellar vesicles (GUVs), we show that physical confinement can cause these proteins to form much more complex structures, including rings and asters at GUV peripheries and centers; the prevalence of different structures depends on GUV size. Strikingly, we found that α-actinin and fascin self-sort into separate domains in the aster structures with actin bundles whose apparent stiffness depends on the ratio of the relative concentrations of α-actinin and fascin. The observed boundary-imposed effect on protein sorting may be a general mechanism for creating emergent structures in biopolymer networks with multiple crosslinkers

    Use of MMG signals for the control of powered orthotic devices: Development of a rectus femoris measurement protocol

    Get PDF
    Copyright © 2009 Rehabilitation Engineering and Assistive Technology Society (RESNA). This is an Author's Accepted Manuscript of an article published in Assistive Technology, 21(1), 1 - 12, 2009, copyright Taylor & Francis, available online at: http://www.tandfonline.com/10.1080/10400430902945678.A test protocol is defined for the purpose of measuring rectus femoris mechanomyographic (MMG) signals. The protocol is specified in terms of the following: measurement equipment, signal processing requirements, human postural requirements, test rig, sensor placement, sensor dermal fixation, and test procedure. Preliminary tests of the statistical nature of rectus femoris MMG signals were performed, and Gaussianity was evaluated by means of a two-sided Kolmogorov-Smirnov test. For all 100 MMG data sets obtained from the testing of two volunteers, the null hypothesis of Gaussianity was rejected at the 1%, 5%, and 10% significance levels. Most skewness values were found to be greater than 0.0, while all kurtosis values were found to be greater than 3.0. A statistical convergence analysis also performed on the same 100 MMG data sets suggested that 25 MMG acquisitions should prove sufficient to statistically characterize rectus femoris MMG. This conclusion is supported by the qualitative characteristics of the mean rectus femoris MMG power spectral densities obtained using 25 averages

    Optimisation of variables for studying dilepton transverse momentum distributions at hadron colliders

    Get PDF
    In future measurements of the dilepton (Z/γZ/\gamma^*) transverse momentum, \Qt, at both the Tevatron and LHC, the achievable bin widths and the ultimate precision of the measurements will be limited by experimental resolution rather than by the available event statistics. In a recent paper the variable \at, which corresponds to the component of \Qt\ that is transverse to the dilepton thrust axis, has been studied in this regard. In the region, \Qt\ << 30 GeV, \at\ has been shown to be less susceptible to experimental resolution and efficiency effects than the \Qt. Extending over all \Qt, we now demonstrate that dividing \at\ (or \Qt) by the measured dilepton invariant mass further improves the resolution. In addition, we propose a new variable, \phistarEta, that is determined exclusively from the measured lepton directions; this is even more precisely determined experimentally than the above variables and is similarly sensitive to the \Qt. The greater precision achievable using such variables will enable more stringent tests of QCD and tighter constraints on Monte Carlo event generator tunes.Comment: 8 pages, 5 figures, 2 table

    A ‘Machine Control Shell’ for ‘Next Generation’ Manufacturing Machines

    Full text link

    The design and characterization of a 300 channel, optimized full-band millimeter filterbank for science with SuperSpec

    Get PDF
    SuperSpec is an integrated, on-chip spectrometer for millimeter and sub-millimeter astronomy. We report the approach, design optimization, and partial characterization of a 300 channel filterbank covering the 185 to 315 GHz frequency band that targets a resolving power R ~ 310, and fits on a 3.5×5.5 cm chip. SuperSpec uses a lens and broadband antenna to couple radiation into a niobium microstrip that feeds a bank of niobium microstrip half-wave resonators for frequency selectivity. Each half-wave resonator is coupled to the inductor of a titanium nitride lumped-element kinetic inductance detector (LEKID) that detects the incident radiation. The device was designed for use in a demonstration instrument at the Large Millimeter Telescope (LMT)

    Radiation damage in the LHCb vertex locator

    Get PDF
    The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately 45 × 1012 1 MeV neutron equivalent (1 MeV neq). At the operational sensor temperature of approximately −7 °C, the average rate of sensor current increase is 18 μA per fb−1, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of Eg = 1.16±0.03±0.04 eV obtained. The first observation of n+-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around 15 × 1012 of 1 MeV neq. The only n+-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately 3 × 1012 1 MeV neq, a decrease in the Effective Depletion Voltage (EDV) of around 25 V is observed. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n+-on-n type sensors, with rates of (1.43±0.16) × 10−12 V/ 1 MeV neq and (1.35±0.25) × 10−12 V/ 1 MeV neq measured for n+-on-p and n+-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed

    SuperSpec: On-chip spectrometer design, characterization, and performance

    Get PDF
    SuperSpec is an integrated, on-chip spectrometer for millimeter and sub-millimeter astronomy. SuperSpec is demonstrating a proof-of-principle multi-beam spectrometer on the sky at the Large Millimeter Telescope (LMT) in Mexico covering the 200 - 300 GHz frequency range with moderate resolution (R ~ 270 - 290). The dual-polarization, three-pixel instrument will consist of 6 SuperSpec spectrometer chips. We present the design and characterization of the devices being used in the first SuperSpec demonstration along with lab testing of the instrument performance
    corecore