188 research outputs found

    Plants Used in Ethnoveterinary Practices by Koyas of Pakhal Wildlife Sanctuary, Andhra Pradesh, India

    Get PDF
    The paper deals with the 21 medicinal plant species used in ethnoveterinary practices by Koya tribes inhabiting in the Pakhal Wildlife Sanctuary, Warangal district, Andhra Pradesh, India

    ОБЗОР СЕМАНТИКИ ЯЗЫКА HTML 5

    Get PDF
    HTML5 несет в себе множество изменений разного уровня и разной важности. Принципиально, ключевые изменения можно разделить на 5 блоков: семантика, мультимедиа, динамичная графика, веб-формы, JavaScript APls. В данной статье рассмотрен обзор семантики HTML5 в котором появился ряд новых семантических тегов, позволяющих более осмысленно организовывать внутреннюю структуру веб-страни

    Panorama of neoplasms of upper GI tract: a 5 year research study

    Get PDF
    Background: The diseases of the gastrointestinal tract (GIT) are the most common and leading cause of morbidity and mortality than the disorders of any other systems of the body. Gastrointestinal (GI) tract tumors are one of the most common cancers accounting for 11% of all cancers. Among these tumors, upper gastrointestinal tract malignancies are quite aggressive with a dismal prognosis. Malignant tumors are most common than benign. The most common carcinoma of the esophagus is Squamous cell carcinoma (SCC). Incidence of SCC is less than 5 per 100,000 populations in males and 1 per 100,000 populations in females. Gastric cancer was the second most common cancer in the World and 60% of them occurred in developing countries. The most common carcinoma of the Stomach is Adenocarcinoma.Aim & Objectives: To study the spectrum of neoplastic lesions of the upper gastrointestinal tract by the examination of endoscopic biopsies and surgically resected specimens. To determine the degree of severity of the malignancies by assessing the depth of invasion, Lymph nodal & Omental spread.Methods: The present study is both retrospective & prospective study for a period of 5 years from January 2007 to December 2011. The sample size includes all the endoscopic biopsies & surgically resected specimens of gastrointestinal tract received at Department of Pathology, S.V. Medical College, Tirupati. The study also obtained clearance from the ethical committee of the institution. The biopsy specimens thus obtained were fixed in 10% buffered neutral formalin. The sections were stained routinely with H & E. Special stains and IHC done wherever necessary.Results: we have received 120 specimens regarding the upper gastrointestinal system. Among these 120 specimens, 71 specimens were endoscopic biopsies & 49 specimens were surgically resected specimens. Out of 71 Endoscopic biopsies 28 biopsies were malignant among which 2 was esophagus and 26 were stomach. Out of 49 surgically resected specimens 1 was benign and 32 were malignant tumors. Out of 59 neoplasms of stomach there were single cases each of Sub mucosal Lipoma, Malignant lymphoma, GIST & 56 cases of Adenocarcinoma & its variants were noted.Conclusion: Most of the neoplasms are of stomach (97%). All the neoplasms are malignant except one benign lesion sub mucous lipoma of stomach. Most of the neoplasms of stomach were Adenocarcinoma (96.5%). Both tumors of esophagus were squamous cell carcinoma occurred after 50 years of age.

    Study of various congenital anomalies in fetal and neonatal autopsy

    Get PDF
    Background: The study of dead is to save the livings. The growing awareness that still births and infant mortalities are unable to reduction has led to a wide spread desire for more information regarding the cause of these deaths. Congenital malformations have become important cause of fetal and neonatal (perinatal) mortality in developed countries and would very soon be increasingly important determinants of fetal and neonatal mortality in developing countries like India. In spite of antenatal diagnostic modality still the fetal autopsy plays the vital role in the conformation as well as identification of congenital anomalies and also for the counseling of the parents, to prevent the fetal congenital anomalies in further pregnancies. This study was undertaken with the purpose of finding out cause of death during the perinatal period at government maternity hospital and pediatric department S.V.R.R.G.G.H. & S.V. medical college Tirupati, and to study the clinical and pathological findings (Gross & microscopic) in fetal and neonatal death.Methods: The present study of congenital anomalies in fetal and neonatal deaths was done at S.V. medical college, Tirupati, over a time period of 2 years from September 2008 to 2010 August. Consent for autopsy in requested compassionately, respectfully and fully informed. The present study included dead fetus and neonates with gestational age above 20 weeks of intra uterine life and within 7 days of post natal life. All fetuses of gestational age <20 weeks and all neonates above 7 days of age were excluded from the study. The study also obtained clearance from the ethical committee of the institution. Autopsy was performed by standard technique adopted by Edith L. Potter. External and internal findings followed by histopathological examination, and autopsy findings were compared with available ultrasound findings.Results: A total of 46 Autopsies performed, 40 (87%) were fetal deaths, 6 (13%) were early neonatal deaths. In a total of 46 fetuses, there were 13 male and 33 female babies. On external examination of 46 fetal and Neonatal (perinatal) deaths, 8 (17.39%) babies showed congenital malformation. On internal examination of the 46 fetal and Neonatal (perinatal) deaths, 4 babies showed internal congenital anomalies. A total of 46 anatomical and histopathologic examinations were done among fetal and neonatal (perinatal) deaths. Out of 13 autopsies on male babies, 2 had congenital malformation and 33 autopsies on female babies, 7 had congenital malformations. Congenital anomalies were commonest in the birth weight group of 1000-1500 grams accounting for 9 cases. Malformations of central nervous system (33.33%) were most common followed by musculoskeletal system (16.66%), genitourinary and respiratory system (8.33%) respectively.Conclusion: Most number of perinatal deaths occurred in low birth weight and preterm babies. Study of malformations greatly helpful in genetic counseling and prenatal diagnosis in successive pregnancies

    Successful Transplantation of a Split Crossed Fused Ectopic Kidney into a Patient with End-Stage Renal Disease

    Get PDF
    Potential donors with congenital renal anomalies but normal renal function are often overlooked because of a possible increase in technical difficulty and complications associated with the surgery. However, as the waiting list for a deceased donor kidney transplant continues to grow, it is important to consider these kidneys for potential transplant. This paper describes the procurement of a crossed fused ectopic kidney, and subsequent parenchymal transection prior to transplantation as part of a combined simultaneous kidney pancreas transplant. The transplant was uncomplicated, and the graft had immediate function. The patient is now two years from transplant with excellent function

    Pretransplant Fasting Glucose Predicts New-Onset Diabetes after Liver Transplantation

    Get PDF
    New-onset diabetes after transplantation (NODAT) is common after liver transplant and associated with poorer outcomes. The aim of this study was to identify risk factors for NODAT in liver transplant recipients off corticosteroids. In 225 adult nondiabetic liver transplant recipients, the mean age was 51.7 years, the majority were men (71%), and half had HCV (49%). The mean calculated MELD score at transplantation was 18.7, and 19% underwent living-donor transplant (LDLT). One year after transplantation, 17% developed NODAT, and an additional 16% had impaired fasting glucose. The incidence of NODAT in patients with HCV was 26%. In multivariate analysis, HCV, pretransplant FPG, and LDLT were significant. Each 10 mg/dL increase in pretransplant FPG was associated with a twofold increase in future development of NODAT. The incidence of NODAT after liver transplant in patients off corticosteroids is 17%. Risk factors for developing NODAT include HCV and pretransplant FPG; LDLT is protective

    Functional Characterization of Aquaporin-4 Specific T Cells: Towards a Model for Neuromyelitis Optica

    Get PDF
    Antibodies to the water channel protein aquaporin-4 (AQP4), which is expressed in astrocytic endfeet at the blood brain barrier, have been identified in the serum of Neuromyelitis optica (NMO) patients and are believed to induce damage to astrocytes. However, AQP4 specific T helper cell responses that are required for the generation of anti-AQP4 antibodies and most likely also for the formation of intraparenchymal CNS lesions have not been characterized. specific T cells were present in the natural T cell repertoire of wild type C57BL/6 mice and T cell lines were raised. However, active immunization with these AQP4 peptides did not induce signs of spinal cord disease. Rather, sensitization with AQP4 peptides resulted in production of IFN-γ, but also IL-5 and IL-10 by antigen-specific T cells. Consistent with this cytokine profile, the AQP4 specific antibody response upon immunization with full length AQP4 included IgG1 and IgG2, which are associated with a mixed Th2/Th1 T cell response. restricted AQP4 specific T cell epitopes will allow us to investigate how AQP4 specific autoimmune reactions are regulated and to establish faithful mouse models of NMO that include both cellular and humoral responses against AQP4

    Design, Performance, and Calibration of CMS Hadron-Barrel Calorimeter Wedges

    Get PDF
    Extensive measurements have been made with pions, electrons and muons on four production wedges of the Compact Muon Solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. Data were taken both with and without a prototype electromagnetic lead tungstate crystal calorimeter (EB) in front of the hadron calorimeter. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. These measurements set the absolute calibration of the HB prior to first pp collisions to approximately 4%

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile

    Synchronization and Timing in CMS HCAL

    Get PDF
    The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance
    corecore