591 research outputs found

    Association between SARS-CoV-2 exposure and antibody status among healthcare workers in two London hospitals: a cross-sectional study.

    Get PDF
    Background: Patient-facing (frontline) health-care workers (HCWs) are at high risk of repeated exposure to SARS-CoV-2. Aim: We sought to determine the association between levels of frontline exposure and likelihood of SARS-CoV-2 seropositivity amongst HCW. Methods: A cross-sectional study was undertaken using purposefully collected data from HCWs at two hospitals in London, United Kingdom (UK) over eight weeks in May-June 2020. Information on sociodemographic, clinical and occupational characteristics was collected using an anonymised questionnaire. Serology was performed using split SARS-CoV-2 IgM/IgG lateral flow immunoassays. Exposure risk was categorised into five pre-defined ordered grades. Multivariable logistic regression was used to examine the association between being frontline and SARS-CoV-2 seropositivity after controlling for other risks of infection. Findings: 615 HCWs participated in the study. 250/615 (40.7%) were SARS-CoV-2 IgM and/or IgG positive. After controlling for other exposures, there was non-significant evidence of a modest association between being a frontline HCW (any level) and SARS-CoV-2 seropositivity compared to non-frontline status (OR 1.39, 95% CI 0.84-2.30, P=0.200). There was 15% increase in the odds of SARS-CoV-2 seropositivity for each step along the frontline exposure gradient (OR 1.15, 95% CI 1.00-1.32, P=0.043). Conclusion: We found a high SARS-CoV-2 IgM/IgG seropositivity with modest evidence for a dose-response association between increasing levels of frontline exposure risk and seropositivity. Even in well-resourced hospital settings, appropriate use of personal protective equipment, in addition to other transmission-based precautions for inpatient care of SARS-CoV-2 patients could reduce the risk of hospital-acquired SARS-CoV-2 infection among frontline HCW

    High-throughput clone library analysis of the mucosa-associated microbiota reveals dysbiosis and differences between inflamed and non-inflamed regions of the intestine in inflammatory bowel disease.

    Get PDF
    BACKGROUND: The gut microbiota is thought to play a key role in the development of the inflammatory bowel diseases Crohn's disease (CD) and ulcerative colitis (UC). Shifts in the composition of resident bacteria have been postulated to drive the chronic inflammation seen in both diseases (the "dysbiosis" hypothesis). We therefore specifically sought to compare the mucosa-associated microbiota from both inflamed and non-inflamed sites of the colon in CD and UC patients to that from non-IBD controls and to detect disease-specific profiles. RESULTS: Paired mucosal biopsies of inflamed and non-inflamed intestinal tissue from 6 CD (n = 12) and 6 UC (n = 12) patients were compared to biopsies from 5 healthy controls (n = 5) by in-depth sequencing of over 10,000 near full-length bacterial 16S rRNA genes. The results indicate that mucosal microbial diversity is reduced in IBD, particularly in CD, and that the species composition is disturbed. Firmicutes were reduced in IBD samples and there were concurrent increases in Bacteroidetes, and in CD only, Enterobacteriaceae. There were also significant differences in microbial community structure between inflamed and non-inflamed mucosal sites. However, these differences varied greatly between individuals, meaning there was no obvious bacterial signature that was positively associated with the inflamed gut. CONCLUSIONS: These results may support the hypothesis that the overall dysbiosis observed in inflammatory bowel disease patients relative to non-IBD controls might to some extent be a result of the disturbed gut environment rather than the direct cause of disease. Nonetheless, the observed shifts in microbiota composition may be important factors in disease maintenance and severity

    An unfolding signifier: London's Baltic Exchange in Tallinn

    Get PDF
    In the summer of 2007 an unusual cargo arrived at Muuga and Paldiski harbors outside Tallinn. It consisted of nearly 50 containers holding over 1,000 tons of building material ranging from marble columns, staircases and fireplaces, to sculpted allegorical figures, wooden paneling and old-fashioned telephone booths. They were once part of the Baltic Exchange in the City of London. Soon they will become facets of the landscape of Tallinn. The following article charts this remarkable story and deploys this fragmented monument to analyze three issues relating to the Estonian capital: the relocation of the ‘Bronze Soldier’, the demolition of the Sakala Culture Center, and Tallinn’s future role as European Cultural Capital in 2011

    Point-of-care serological assays for delayed SARS-CoV-2 case identification among health-care workers in the UK: a prospective multicentre cohort study

    Get PDF
    BACKGROUND: Health-care workers constitute a high-risk population for acquisition of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Capacity for acute diagnosis via PCR testing was limited for individuals with mild to moderate SARS-CoV-2 infection in the early phase of the COVID-19 pandemic and a substantial proportion of health-care workers with suspected infection were not tested. We aimed to investigate the performance of point-of-care and laboratory serology assays and their utility in late case identification, and to estimate SARS-CoV-2 seroprevalence. METHODS: We did a prospective multicentre cohort study between April 8 and June 12, 2020, in two phases. Symptomatic health-care workers with mild to moderate symptoms were eligible to participate 14 days after onset of COVID-19 symptoms, as per the Public Health England (PHE) case definition. Health-care workers were recruited to the asymptomatic cohort if they had not developed PHE-defined COVID-19 symptoms since Dec 1, 2019. In phase 1, two point-of-care lateral flow serological assays, the Onsite CTK Biotech COVID-19 split IgG/IgM Rapid Test (CTK Bitotech, Poway, CA, USA) and the Encode SARS-CoV-2 split IgM/IgG One Step Rapid Test Device (Zhuhai Encode Medical Engineering, Zhuhai, China), were evaluated for performance against a laboratory immunoassay (EDI Novel Coronavirus COVID-19 IgG ELISA kit [Epitope Diagnostics, San Diego, CA, USA]) in 300 samples from health-care workers and 100 pre-COVID-19 negative control samples. In phase 2 (n=6440), serosurveillance was done among 1299 (93·4%) of 1391 health-care workers reporting symptoms, and in a subset of asymptomatic health-care workers (405 [8·0%] of 5049). FINDINGS: There was variation in test performance between the lateral flow serological assays; however, the Encode assay displayed reasonable IgG sensitivity (127 of 136; 93·4% [95% CI 87·8-96·9]) and specificity (99 of 100; 99·0% [94·6-100·0]) among PCR-proven cases and good agreement (282 of 300; 94·0% [91·3-96·7]) with the laboratory immunoassay. By contrast, the Onsite assay had reduced sensitivity (120 of 136; 88·2% [95% CI 81·6-93·1]) and specificity (94 of 100; 94·0% [87·4-97·8]) and agreement (254 of 300; 84·7% [80·6-88·7]). Five (7%) of 70 PCR-positive cases were negative across all assays. Late changes in lateral flow serological assay bands were recorded in 74 (9·3%) of 800 cassettes (35 [8·8%] of 400 Encode assays; 39 [9·8%] of 400 Onsite assays), but only seven (all Onsite assays) of these changes were concordant with the laboratory immunoassay. In phase 2, seroprevalence among the workforce was estimated to be 10·6% (95% CI 7·6-13·6) in asymptomatic health-care workers and 44·7% (42·0-47·4) in symptomatic health-care workers. Seroprevalence across the entire workforce was estimated at 18·0% (95% CI 17·0-18·9). INTERPRETATION: Although a good positive predictive value was observed with both lateral flow serological assays and ELISA, this agreement only occurred if the pre-test probability was modified by a strict clinical case definition. Late development of lateral flow serological assay bands would preclude postal strategies and potentially home testing. Identification of false-negative results among health-care workers across all assays suggest caution in interpretation of IgG results at this stage; for now, testing is perhaps best delivered in a clinical setting, supported by government advice about physical distancing. FUNDING: None

    The R403Q Myosin Mutation Implicated in Familial Hypertrophic Cardiomyopathy Causes Disorder at the Actomyosin Interface

    Get PDF
    Mutations in virtually all of the proteins comprising the cardiac muscle sarcomere have been implicated in causing Familial Hypertrophic Cardiomyopathy (FHC). Mutations in the beta-myosin heavy chain (MHC) remain among the most common causes of FHC, with the widely studied R403Q mutation resulting in an especially severe clinical prognosis. In vitro functional studies of cardiac myosin containing the R403Q mutation have revealed significant changes in enzymatic and mechanical properties compared to wild-type myosin. It has been proposed that these molecular changes must trigger events that ultimately lead to the clinical phenotype.Here we examine the structural consequences of the R403Q mutation in a recombinant smooth muscle myosin subfragment (S1), whose kinetic features have much in common with slow beta-MHC. We obtained three-dimensional reconstructions of wild-type and R403Q smooth muscle S1 bound to actin filaments in the presence (ADP) and absence (apo) of nucleotide by electron cryomicroscopy and image analysis. We observed that the mutant S1 was attached to actin at highly variable angles compared to wild-type reconstructions, suggesting a severe disruption of the actin-myosin interaction at the interface.These results provide structural evidence that disarray at the molecular level may be linked to the histopathological myocyte disarray characteristic of the diseased state

    Early identification of high-risk individuals for monoclonal antibody therapy and prophylaxis is feasible by SARS-CoV-2 anti-spike antibody specific lateral flow assay.

    Get PDF
    Monoclonal antibody therapy has been approved for prophylaxis and treatment of severe COVID-19 infection. Greatest benefit appears limited to those yet to mount an effective immune response from natural infection or vaccination, but concern exists around ability to make timely assessment of immune status of community-based patients where laboratory-based serodiagnostics predominate. Participants were invited to undergo paired laboratory-based (Abbott Architect SARS-CoV-2 IgG Quant II chemiluminescent microparticle immunoassay) and lateral flow assays (LFA; a split SARS-CoV-2 IgM/IgG and total antibody test) able to detect SARS-CoV-2 anti-spike antibodies. LFA band strength was compared with CMIA titer by log-linear regression. Two hundred individuals (median age 43.5 years, IQR 30-59; 60.5% female) underwent testing, with a further 100 control sera tested. Both LFA band strengths correlated strongly with CMIA antibody titers (P < 0.001). LFAs have the potential to assist in early identification of seronegative patients who may demonstrate the greatest benefit from monoclonal antibody treatment
    corecore