13 research outputs found

    Usability, acceptability, and feasibility of two technology-based devices for mental health screening in perinatal care: A comparison of web versus app

    Get PDF
    The use of Information and Communication Technologies (web pages and apps) in mental health has boosted. However, it is unknown which of these two devices can be better in terms of feasibility and acceptability. Our aim is to compare the feasibility, usability, and user satisfaction of two devices (web vs mobile application) of an online program for perinatal depression screening called HappyMom. In total, 348 and 175 perinatal women registered into HappyMom web and app version, respectively. The assessment protocol included different biopsychosocial evaluations (twice during pregnancy and thrice in the postpartum) and a satisfaction questionnaire. Results showed that a higher percentage of women in the web sample (27.3–51.1%) responded to each assessment compared to the app sample (9.1–53.1%). A smaller proportion of women in web sample never responded to any assessments. By contrast, the percentage of women who responded to all assessments was higher in app sample (longitudinal retention sample was 4.6% of web users and 9.1% of app users). In general, high satisfaction was found in both web and app users. Our result showed that online assessment methods are feasible and acceptable by perinatal women. However, dropout rates are a real problem that urge a solution that will be discussed further in the paper. Web and App devices present different advantages and limitations. The choice of one of them must be made taking into account the study’s objective, the sample characteristics, and the dissemination possibilities

    Behavioral frequency discrimination ability of partially deafened cats using cochlear implants

    Get PDF
    The aim of this study was to determine the effects of cochlear implant (CI) use on behavioral frequency discrimination ability in partially deafened cats. We hypothesized that the additional information provided by the CI would allow subjects to perform better on a frequency discrimination task. Four cats with a high frequency hearing loss induced by ototoxic drugs were first trained on a go/no-go, positive reinforcement, frequency discrimination task and reached asymptotic performance (measured by d' - detection theory). Reference frequencies (1, 4, and 7 kHz) were systematically rotated (Block design) every 9-11 days to cover the hearing range of the cats while avoiding bias arising from the order of testing. Animals were then implanted with an intracochlear electrode array connected to a CI and speech processor. They then underwent 6 months of continuous performance measurement with the CI turned on, except for one month when the stimulator was turned off. Overall, subjects performed the frequency discrimination task significantly better with their CI turned on than in the CI-off condition (3-way ANOVA, p  0.5); however, the CI only significantly improved performance for two (1 and 7 kHz) of the three reference frequencies. In this study we were able to show, for the first time, that cats can utilize information provided by a CI in performing a behavioral frequency discrimination task

    An automated psychoacoustic testing apparatus for use in cats

    Get PDF
    Animal behavioral studies make a significant contribution to hearing research and provide vital information which is not available from human subjects. Animal psychoacoustics is usually extremely time consuming and labor intensive; in addition, animals may become stressed, especially if restraints or negative reinforcers such as electric shocks are used. We present a novel behavioral experimental system that was developed to allow efficient animal training in response to acoustic stimuli. Cats were required to perform a relatively simple task of moving toward and away from the device depending on whether the members of a tone pair were different or the same in frequency (go/no-go task). The experimental setup proved to be effective, with all animals (N = 7) performing at above 90% correct on an easy task. Animals were trained within 2-4 weeks and then generated a total of 150-200 trials per day, distributed within approximately 8 self initiated sessions. Data collected using this system were stable over 1 week and repeatable over long test periods (14 weeks). Measured frequency discrimination thresholds from 3 animals at 3 different reference frequencies were comparable with previously published results. The main advantages of the system are: relatively simple setup; large amounts of data can be generated without the need of researcher supervision; multiple animals can be tested simultaneously without removal from home pens; and no electric shocks or restraints are required

    Suprachoroidal electrical stimulation: effects of stimulus pulse parameters on visual cortical responses

    Get PDF
    OBJECTIVE: Neural responses to biphasic constant current pulses depend on stimulus pulse parameters such as polarity, duration, amplitude and interphase gap. The objective of this study was to systematically evaluate and optimize stimulus pulse parameters for a suprachoroidal retinal prosthesis. APPROACH: Normally sighted cats were acutely implanted with platinum electrode arrays in the suprachoroidal space. Monopolar stimulation comprised of monophasic and biphasic constant current pulses with varying polarity, pulse duration and interphase gap. Multiunit responses to electrical stimulation were recorded in the visual cortex. MAIN RESULTS: Anodal stimulation elicited cortical responses with shorter latencies and required lower charge per phase than cathodal stimulation. Clinically relevant retinal stimulation required relatively larger charge per phase compared with other neural prostheses. Increasing the interphase gap of biphasic pulses reduced the threshold of activation; however, the benefits of using an interphase gap need to be considered in light of the pulse duration and polarity used and other stimulation constraints. Based on our results, anodal first biphasic pulses between 300-1200 µs are recommended for suprachoroidal retinal stimulation. SIGNIFICANCE: These results provide insights into the efficacy of different pulse parameters for suprachoroidal retinal stimulation and have implications for the design of safe and clinically relevant stimulators for retinal prostheses

    Ring and peg electrodes for minimally-Invasive and long-term sub-scalp EEG recordings

    Get PDF
    OBJECTIVE: Minimally-invasive approaches are needed for long-term reliable Electroencephalography (EEG) recordings to assist with epilepsy diagnosis, investigation and more naturalistic monitoring. This study compared three methods for long-term implantation of sub-scalp EEG electrodes. METHODS: Three types of electrodes (disk, ring, and peg) were fabricated from biocompatible materials and implanted under the scalp in five ambulatory ewes for 3months. Disk electrodes were inserted into sub-pericranial pockets. Ring electrodes were tunneled under the scalp. Peg electrodes were inserted into the skull, close to the dura. EEG was continuously monitored wirelessly. High resolution CT imaging, histopathology, and impedance measurements were used to assess the status of the electrodes at the end of the study. RESULTS: EEG amplitude was larger in the peg compared with the disk and ring electrodes (p<0.05). Similarly, chewing artifacts were lower in the peg electrodes (p<0.05). Electrode impedance increased after long-term implantation particularly for those within the bone (p<0.01). Micro-CT scans indicated that all electrodes stayed within the sub-scalp layers. All pegs remained within the burr holes as implanted with no evidence of extrusion. Eight of 10 disks partially eroded into the bone by 1.0mm from the surface of the skull. The ring arrays remained within the sub-scalp layers close to implantation site. Histology revealed that the electrodes were encapsulated in a thin fibrous tissue adjacent to the pericranium. Overlying this was a loose connective layer and scalp. Erosion into the bone occurred under the rim of the sub-pericranial disk electrodes. CONCLUSIONS: The results indicate that the peg electrodes provided high quality EEG, mechanical stability, and lower chewing artifact. Whereas, ring electrode arrays tunneled under the scalp enable minimal surgical techniques to be used for implantation and removal