12 research outputs found

    Antenatal dexamethasone for early preterm birth in low-resource countries

    Get PDF
    BACKGROUND: The safety and efficacy of antenatal glucocorticoids in women in low-resource countries who are at risk for preterm birth are uncertain. METHODS: We conducted a multicountry, randomized trial involving pregnant women between 26 weeks 0 days and 33 weeks 6 days of gestation who were at risk for preterm birth. The participants were assigned to intramuscular dexamethasone or identical placebo. The primary outcomes were neonatal death alone, stillbirth or neonatal death, and possible maternal bacterial infection; neonatal death alone and stillbirth or neonatal death were evaluated with superiority analyses, and possible maternal bacterial infection was evaluated with a noninferiority analysis with the use of a prespecified margin of 1.25 on the relative scale. RESULTS: A total of 2852 women (and their 3070 fetuses) from 29 secondary- and tertiary-level hospitals across Bangladesh, India, Kenya, Nigeria, and Pakistan underwent randomization. The trial was stopped for benefit at the second interim analysis. Neonatal death occurred in 278 of 1417 infants (19.6%) in the dexamethasone group and in 331 of 1406 infants (23.5%) in the placebo group (relative risk, 0.84; 95% confidence interval [CI], 0.72 to 0.97; P=0.03). Stillbirth or neonatal death occurred in 393 of 1532 fetuses and infants (25.7%) and in 444 of 1519 fetuses and infants (29.2%), respectively (relative risk, 0.88; 95% CI, 0.78 to 0.99; P=0.04); the incidence of possible maternal bacterial infection was 4.8% and 6.3%, respectively (relative risk, 0.76; 95% CI, 0.56 to 1.03). There was no significant between-group difference in the incidence of adverse events. CONCLUSIONS: Among women in low-resource countries who were at risk for early preterm birth, the use of dexamethasone resulted in significantly lower risks of neonatal death alone and stillbirth or neonatal death than the use of placebo, without an increase in the incidence of possible maternal bacterial infection.Fil: Oladapo, Olufemi T.. Organizacion Mundial de la Salud; ArgentinaFil: Vogel, Joshua P.. Organizacion Mundial de la Salud; ArgentinaFil: Piaggio, Gilda. Organizacion Mundial de la Salud; ArgentinaFil: Nguyen, My-Huong. Organizacion Mundial de la Salud; ArgentinaFil: Althabe, Fernando. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Centro de Investigaciones en Epidemiología y Salud Pública. Instituto de Efectividad Clínica y Sanitaria. Centro de Investigaciones en Epidemiología y Salud Pública; ArgentinaFil: Metin Gülmezoglu, A.. Organizacion Mundial de la Salud; ArgentinaFil: Bahl, Rajiv. Organizacion Mundial de la Salud; ArgentinaFil: Rao, Suman P.N.. Organizacion Mundial de la Salud; ArgentinaFil: de Costa, Ayesha. Organizacion Mundial de la Salud; ArgentinaFil: Gupta, Shuchita. Organizacion Mundial de la Salud; ArgentinaFil: Shahidullah, Mohammod. No especifíca;Fil: Chowdhury, Saleha B.. No especifíca;Fil: Ara, Gulshan. No especifíca;Fil: Akter, Shaheen. No especifíca;Fil: Akhter, Nasreen. No especifíca;Fil: Dey, Probhat R.. No especifíca;Fil: Abdus Sabur, M.. No especifíca;Fil: Azad, Mohammad T.. No especifíca;Fil: Choudhury, Shahana F.. No especifíca;Fil: Matin, M.A.. No especifíca;Fil: Goudar, Shivaprasad S.. No especifíca;Fil: Dhaded, Sangappa M.. No especifíca;Fil: Metgud, Mrityunjay C.. No especifíca;Fil: Pujar, Yeshita V.. No especifíca;Fil: Somannavar, Manjunath S.. No especifíca;Fil: Vernekar, Sunil S.. No especifíca;Fil: Herekar, Veena R.. No especifíca;Fil: Bidri, Shailaja R.. No especifíca;Fil: Mathapati, Sangamesh S.. No especifíca;Fil: Patil, Preeti G.. No especifíca;Fil: Patil, Mallanagouda M.. No especifíca;Fil: Gudadinni, Muttappa R.. No especifíca;Fil: Bijapure, Hidaytullah R.. No especifíca;Fil: Mallapur, Ashalata A.. No especifíca;Fil: Katageri, Geetanjali M.. No especifíca;Fil: Chikkamath, Sumangala B.. No especifíca;Fil: Yelamali, Bhuvaneshwari C.. No especifíca;Fil: Pol, Ramesh R.. No especifíca;Fil: Misra, Sujata S.. No especifíca;Fil: Das, Leena. No especifíca

    Low cost calibrated mechanical noisemaker for hearing screening of neonates in resource constrained settings

    No full text
    Background & objectives: There is a need to develop an affordable and reliable tool for hearing screening of neonates in resource constrained, medically underserved areas of developing nations. This study valuates a strategy of health worker based screening of neonates using a low cost mechanical calibrated noisemaker followed up with parental monitoring of age appropriate auditory milestones for detecting severe-profound hearing impairment in infants by 6 months of age. Methods: A trained health worker under the supervision of a qualified audiologist screened 425 neonates of whom 20 had confirmed severe-profound hearing impairment. Mechanical calibrated noisemakers of 50, 60, 70 and 80 dB (A) were used to elicit the behavioural responses. The parents of screened neonates were instructed to monitor the normal language and auditory milestones till 6 months of age. This strategy was validated against the reference standard consisting of a battery of tests - namely, auditory brain stem response (ABR), otoacoustic emissions (OAE) and behavioural assessment at 2 years of age. Bayesian prevalence weighted measures of screening were calculated. Results: The sensitivity and specificity was high with least false positive referrals for. 70 and 80 dB (A) noisemakers. All the noisemakers had 100 per cent negative predictive value. 70 and 80 dB (A) noisemakers had high positive likelihood ratios of 19 and 34, respectively. The probability differences for pre- and post- test positive was 43 and 58 for 70 and 80 dB (A) noisemakers, respectively. Interpretation & conclusions: In a controlled setting, health workers with primary education can be trained to use a mechanical calibrated noisemaker made of locally available material to reliably screen for severe-profound hearing loss in neonates. The monitoring of auditory responses could be done by informed parents. Multi-centre field trials of this strategy need to be carried out to examine the feasibility of community health care workers using it in resource constrained settings of developing nations to implement an effective national neonatal hearing screening programme

    Correction to: An autosomal dominant neurological disorder caused by de novo variants in FAR1 resulting in uncontrolled synthesis of ether lipids (Genetics in Medicine, (2021), 23, 4, (740-750), 10.1038/s41436-020-01027-3)

    No full text
    In the original author list, Seth Perlman’s degrees were listed as MD, PhD. Dr Perlman’s degree is MD. The original version has been corrected

    An autosomal dominant neurological disorder caused by de novo variants in FAR1 resulting in uncontrolled synthesis of ether lipids

    No full text
    Purpose: In this study we investigate the disease etiology in 12 patients with de novo variants in FAR1 all resulting in an amino acid change at position 480 (p.Arg480Cys/His/Leu). Methods: Following next-generation sequencing and clinical phenotyping, functional characterization was performed in patients’ fibroblasts using FAR1 enzyme analysis, FAR1 immunoblotting/immunofluorescence, and lipidomics. Results: All patients had spastic paraparesis and bilateral congenital/juvenile cataracts, in most combined with speech and gross motor developmental delay and truncal hypotonia. FAR1 deficiency caused by biallelic variants results in defective ether lipid synthesis and plasmalogen deficiency. In contrast, patients’ fibroblasts with the de novo FAR1 variants showed elevated plasmalogen levels. Further functional studies in fibroblasts showed that these variants cause a disruption of the plasmalogen-dependent feedback regulation of FAR1 protein levels leading to uncontrolled ether lipid production. Conclusion: Heterozygous de novo variants affecting the Arg480 residue of FAR1 lead to an autosomal dominant disorder with a different disease mechanism than that of recessive FAR1 deficiency and a diametrically opposed biochemical phenotype. Our findings show that for patients with spastic paraparesis and bilateral cataracts, FAR1 should be considered as a candidate gene and added to gene panels for hereditary spastic paraplegia, cerebral palsy, and juvenile cataracts

    Achievements in Cancer Research and its Therapeutics in Hundred Years

    No full text

    ILC Reference Design Report Volume 1 - Executive Summary

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization

    ILC Reference Design Report Volume 4 - Detectors

    No full text
    This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics
    corecore