8 research outputs found

    Sub-pixel correlation length neutron imaging:Spatially resolved scattering information of microstructures on a macroscopic scale

    Get PDF
    Neutron imaging and scattering give data of significantly different nature and traditional methods leave a gap of accessible structure sizes at around 10 micrometers. Only in recent years overlap in the probed size ranges could be achieved by independent application of high resolution scattering and imaging methods, however without providing full structural information when microstructures vary on a macroscopic scale. In this study we show how quantitative neutron dark-field imaging with a novel experimental approach provides both sub-pixel resolution with respect to microscopic correlation lengths and imaging of macroscopic variations of the microstructure. Thus it provides combined information on multiple length scales. A dispersion of micrometer sized polystyrene colloids was chosen as a model system to study gravity induced crystallisation of microspheres on a macro scale, including the identification of ordered as well as unordered phases. Our results pave the way to study heterogeneous systems locally in a previously impossible manner.ISSN:2045-232

    Small Angle Scattering in Neutron Imaging—A Review

    Get PDF
    Conventional neutron imaging utilizes the beam attenuation caused by scattering and absorption through the materials constituting an object in order to investigate its macroscopic inner structure. Small angle scattering has basically no impact on such images under the geometrical conditions applied. Nevertheless, in recent years different experimental methods have been developed in neutron imaging, which enable to not only generate contrast based on neutrons scattered to very small angles, but to map and quantify small angle scattering with the spatial resolution of neutron imaging. This enables neutron imaging to access length scales which are not directly resolved in real space and to investigate bulk structures and processes spanning multiple length scales from centimeters to tens of nanometers

    Dynamic volume magnetic domain wall imaging in grain oriented electrical steel at power frequencies with accumulative high-frame rate neutron dark-field imaging

    Get PDF
    Abstract The mobility of magnetic domains forms the link between the basic physical properties of a magnetic material and its global characteristics such as permeability and saturation field. Most commonly, surface domain structure are studied using magneto-optical Kerr microscopy. The limited information depth of approx. 20 nanometers, however, allows only for an indirect interpretation of the internal volume domain structures. Here we show how accumulative high-frame rate dynamic neutron dark-field imaging is able for the first time to visualize the dynamic of the volume magnetic domain structures in grain oriented electrical steel laminations at power frequencies. In particular we studied the volume domain structures with a spatial resolution of ∼100 μm and successfully quantified domain sizes, wall velocities, domain annihilation and its duration and domain wall multiplication in real time recordings at power frequencies of 10, 25 and 50 Hz with ±262.5 A/m and ±525 A/m (peak to peak) applied field

    Visibility simulation of realistic grating interferometers including grating geometries and energy spectra

    Get PDF
    The performance of X-ray and neutron grating interferometers is characterised by their visibility, which is a measure for the maximum achievable contrast. In this study we show how the real grating geometry in a grating interferometer with three gratings impacts the interference and self projection that leads to visibility in the first place. We quantify the individual contributions of wavelength distributions and grating shapes in terms of visibility reduction by determining the absolute as well as relative effect of each contribution. The understanding of the impact of changed geometry and wavelength distributions on the interference of neutrons/X-rays allows us to present the first fully quantitative model of a grating interferometer setup. We demonstrate the capability of the simulation framework by building a model of the neutron grating interferometer at the ICON beamline and directly comparing simulated and measured visibility values. The general nature of the model makes it possible to extend it to any given grating interferometer for both X-rays and neutrons

    Characterization of oriented microstructures through anisotropic small-angle scattering by 2D neutron dark-field imaging

    No full text
    Within neutron imaging, different methods have been developed with the aim to go beyond the conventional contrast modalities, such as grating interferometry. Existing grating interferometers are sensitive to scattering in a single direction only, and thus investigations of anisotropic scattering structures imply the need for a circular scan of either the sample or the gratings. Here we propose an approach that allows assessment of anisotropic scattering in a single acquisition mode and to broaden the range of the investigation with respect to the probed correlation lengths. This is achieved by a far-field grating interferometer with a tailored 2D-design. The combination of a directional neutron dark-field imaging approach with a scan of the sample to detector distance yields to the characterization of the local 2D real-space correlation functions of a strongly oriented sample analogous to conventional small-angle scattering. Our results usher in quantitative and spatially resolved investigations of anisotropic and strongly oriented systems beyond current capabilities
    corecore