24 research outputs found

    A Survey on the Use of Spirometry in Small Animal Anaesthesia and Critical Care

    Get PDF
    The objective was to document the use of spirometry and ventilation settings in small animal anaesthesia and intensive care through a descriptive, open, online, anonymous survey. The survey was advertised on social media and via email. Participation was voluntary. The google forms platform was used. It consisted of eight sections in English: demographic information, use of spirometry in spontaneously ventilating/mechanically ventilated dogs, need for spirometry, equipment available and calibration status, ventilation modes, spirometry displays, compliance (CRS) and resistance (RRS) of the respiratory system. Simple descriptive analyses were applied. There were 128 respondents. Respondents used spirometry more in ventilated dogs than during spontaneous breathing. Over 3/4 of the respondents considered spirometry essential in “selected” (43%) or “most” cases (33%). Multiple devices and technologies were used. The majority of the respondents were not directly involved in or informed about the calibration of their equipment. Of all displays, pressure-volume loops were the most common. Values of CRS and RRS were specifically monitored in more than 50% of cases by 44% of the respondents only. A variety of ventilation modes was used. Intensivists tend to use smaller VT than anaesthetists. More information on reference intervals of CRS and RRS and technical background on spirometers is required

    Do the Manual or Computer-Controlled Flowmeters Generate Similar Isoflurane Concentrations in Tafonius?

    Get PDF
    Introduction: Tafonius is an anesthesia machine with computer-controlled monitor and ventilator. We compared the isoflurane fluctuations in the circuit with manual (MF) or computer-driven (CF) flowmeters, investigated the origin of the differences and assessed whether isoflurane concentration time course followed a one-compartment model.Material and Methods: A calibrated TEC-3 isoflurane vaporizer was used. Gas composition and flows were measured using a multiparametric monitor and a digital flowmeter. Measurements included: (1) Effects of various FiO2 with MF/CF on the isoflurane fraction changes in the breathing system during mechanical ventilation of a lung model; wash-in kinetic was fitted to a compartmental model; (2) Gas outflow at the common gas outlet (CGO) with MF/CF at different FiO2; (3) Isoflurane output of the vaporizer at various dial settings with MF/CF set at different flows without and with reduction of the CGO diameter.Results: (1) The 3% targeted isoflurane concentration was not reached; additional time was required to reach specific concentrations with CF (lowest FiO2, longer time). The exponential course fitted a two-compartment model; (2) Set and measured flows were identical with MF. With CF at 0.21 FiO2, flow was intermittently 7.6 L min−1 or zero (mean total: 38% of the set flow); with CF at 1.00 FiO2, flow was 10.6 L min−1 or zero (mean: 4–5.3 L min−1); with 0.21 < FiO2 < 1.00, combined flow was intermittent (maximum output: 15.6 L min−1); (3) With MF, isoflurane output was matching dial setting at 5 L min−1 but was lower at higher flows; with CF generating intermittent flows, isoflurane output was fluctuating. With the 4 mm diameter CGO, isoflurane concentration was close to dial setting with both MF and CF. With a 14 G CGO, isoflurane concentration was lower than dial setting with MF, higher with CF.Conclusions and Clinical Relevance: Using MF or CF led to different isoflurane fraction time course in Tafonius. Flows were lower than set with CF; the TEC-3 did not compensate for high/intermittent flows and pressures; the CGO diameter influenced isoflurane output

    Enantiospecific pharmacokinetics of intravenous dexmedetomidine in beagles.

    Get PDF
    The goal of this study was to investigate the pharmacokinetic (PK) behaviour of dexmedetomidine in dogs administered as a pure enantiomer versus as part of a racemic mixture. Eight unmedicated intact purpose-bread beagles were included. Two intravenous treatments of either medetomidine or dexmedetomidine were administered at 10- to 14-day intervals. Atipamezole or saline solution was administered intramuscularly 45 min later. Venous blood samples were collected into EDTA collection tubes, and the quantification of dexmedetomidine and levomedetomidine was performed by chiral LC-MS/MS. All dogs appeared sedated after each treatment without complication. Plasma concentrations of levomedetomidine were measured only in the racemic group and were 51.4% (51.4%-56.1%) lower than dexmedetomidine. Non-compartmental analysis (NCA) was performed for both drugs, while dexmedetomidine data were further described using a population pharmacokinetic approach. A standard two-compartment mammillary model with linear elimination with combined additive and multiplicative error model for residual unexplained variability was established for dexmedetomidine. An exponential model was finally retained to describe inter-individual variability on parameters of clearance (Cl1 ) and central and peripheral volumes of distribution (V1 , V2 ). No effect of occurrence, levomedetomidine or atipamezole could be observed on dexmedetomidine PK parameters. Dexmedetomidine did not undergo significantly different PK when administered alone or as part of the racemic mixture in otherwise unmedicated dogs

    Etude des interactions entre les processus physiques et biologiques intervenant dans la production de l'huitre Crassostrea gigas (Thunberg) du bassin de Marennes-Oleron: essais de modelisation

    No full text
    SIGLEAvailable from INIST (FR), Document Supply Service, under shelf-number : T 80560 / INIST-CNRS - Institut de l'Information Scientifique et TechniqueFRFranc

    Do the Manual or Computer-Controlled Flowmeters Generate Similar Isoflurane Concentrations in Tafonius?

    Get PDF
    Introduction: Tafonius is an anesthesia machine with computer-controlled monitor and ventilator. We compared the isoflurane fluctuations in the circuit with manual (MF) or computer-driven (CF) flowmeters, investigated the origin of the differences and assessed whether isoflurane concentration time course followed a one-compartment model. Material and Methods: A calibrated TEC-3 isoflurane vaporizer was used. Gas composition and flows were measured using a multiparametric monitor and a digital flowmeter. Measurements included: (1) Effects of various FiO2 with MF/CF on the isoflurane fraction changes in the breathing system during mechanical ventilation of a lung model; wash-in kinetic was fitted to a compartmental model; (2) Gas outflow at the common gas outlet (CGO) with MF/CF at different FiO2; (3) Isoflurane output of the vaporizer at various dial settings with MF/CF set at different flows without and with reduction of the CGO diameter. Results: (1) The 3% targeted isoflurane concentration was not reached; additional time was required to reach specific concentrations with CF (lowest FiO2, longer time). The exponential course fitted a two-compartment model; (2) Set and measured flows were identical with MF. With CF at 0.21 FiO2, flow was intermittently 7.6 L min−1 or zero (mean total: 38% of the set flow); with CF at 1.00 FiO2, flow was 10.6 L min−1 or zero (mean: 4–5.3 L min−1); with 0.21 < FiO2 < 1.00, combined flow was intermittent (maximum output: 15.6 L min−1); (3) With MF, isoflurane output was matching dial setting at 5 L min−1 but was lower at higher flows; with CF generating intermittent flows, isoflurane output was fluctuating. With the 4 mm diameter CGO, isoflurane concentration was close to dial setting with both MF and CF. With a 14 G CGO, isoflurane concentration was lower than dial setting with MF, higher with CF. Conclusions and Clinical Relevance: Using MF or CF led to different isoflurane fraction time course in Tafonius. Flows were lower than set with CF; the TEC-3 did not compensate for high/intermittent flows and pressures; the CGO diameter influenced isoflurane output

    Effect of Medetomidine, Dexmedetomidine, and Their Reversal with Atipamezole on the Nociceptive Withdrawal Reflex in Beagles

    Get PDF
    The objectives were: (1) to compare the antinociceptive activity of dexmedetomidine and medetomidine, and (2) to investigate its modulation by atipamezole. This prospective, randomized, blinded experimental trial was carried out on eight beagles. During the first session, dogs received either medetomidine (MED) (0.02 mg kg-1 intravenously (IV)] or dexmedetomidine (DEX) [0.01 mg kg-1 IV), followed by either atipamezole (ATI) (0.1 mg kg-1) or an equivalent volume of saline (SAL) administered intramuscularly 45 min later. The opposite treatments were administered in a second session 10-14 days later. The nociceptive withdrawal reflex (NWR) threshold was determined using a continuous tracking approach. Sedation was scored (0 to 21) every 10 min. Both drugs (MED and DEX) increased the NWR thresholds significantly up to 5.0 (3.7-5.9) and 4.4 (3.9-4.8) times the baseline (p = 0.547), at seven (3-11) and six (4-9) minutes (p = 0.938), respectively. Sedation scores were not different between MED and DEX during the first 45 min (15 (12-17), p = 0.67). Atipamezole antagonized sedation within 25 (15-25) minutes (p = 0.008) and antinociception within five (3-6) minutes (p = 0.008). Following atipamezole, additional analgesics may be needed to maintain pain relief

    A Systematic Review of the Methods of Assessment of Gastro-Oesophageal Reflux in Anaesthetized Dogs

    No full text
    We reviewed the definitions and methods of assessment of gastro-oesophageal reflux (GOR) in anaesthetized dogs. Three databases were used. Titles and abstracts were screened by two of the authors independently. A total of 22 studies was included in the analysis. The definition of GOR implied the presence of fluids not reaching the mouth or nose in the oesophagus in all studies. Most studies considered a change in pH using oesophageal pH meters as the sole method of assessment. Calibration of the pH probe was inconsistently reported. The position of the tip of the oesophageal probe was inconsistent and not always precisely described. The correct positioning in the intended location was verified in a limited number of studies. Some studies considered that GOR had happened for changes in pH below 4.0 or above 7.5 while others considered that GOR had happened when the pH dropped below 4.0 only. Some studies stated that the pH change had to be sustained for a minimum period of time (20 or 30 s) whereas others did not mention any duration. The variability of definitions and methods of assessment of GOR in anaesthetized dogs precludes meaningful comparison of the findings. Re-evaluation and uniformization of the methods appear necessary

    Investigation of selected respiratory effects of (dex)medetomidine in healthy Beagles

    No full text
    Objective: To investigate the effects of sedative doses of intravenous (IV) medetomidine (MED) or dexmedetomidine (DEX) on selected respiratory variables in dogs. Study design: Randomized, blinded, crossover study. Animals: A total of eight healthy adult research Beagles. Methods: Dogs breathing room air had an electrical impedance tomography belt placed around the chest and were maintained in right lateral recumbency. Respiratory rate (fR) in movements minute-1 (mpm) and changes in thoracic impedance (ΔZ) in arbitrary units (AU) were recorded for 120 seconds before (T0) and exactly 10 minutes (T10) after the administration of IV DEX (10 ÎŒg kg-1) or MED (20 ÎŒg kg-1), with a minimum washout period of 10 days between treatments. Minute ΔZ (ΔZ˙) was calculated by multiplying median ΔZ with fR. Data are presented as median (interquartile range). Significance for an overall effect of drugs (DEX versus MED) or treatment (T0 versus T10) was quantified with a two-way analysis of variance for repeated measures, followed by, when appropriate, Wilcoxon's signed rank test for each factor. Results: Overall, fR decreased from 26 (22-29) mpm at T0 to 13 (10-21) mpm at T10 (p = 0.003) and ΔZ increased from 1.133 (0.856-1.599) AU at T0 to 1.650 (1.273-2.813) AU at T10 (p = 0.007), but ΔZ˙ did not change [30.375 (23.411-32.445) AU minute-1 at T0 and 30.581 (22.487-35.091) AU minute-1 at T10]. There was no difference between DEX and MED. Most dogs developed a peculiar breathing pattern characterized by clusters of breaths followed by short periods of apnoea. Conclusions and clinical relevance: Both drugs caused a change in breathing pattern, reduction in fR and increase in ΔZ but did not affect ΔZ˙. It is likely that (dex)medetomidine resulted in reduction in fR and increase in tidal volume without impacting minute volume

    Influence of operating parameters on photocatalytic oxidation treatment efficiency: contact time investigation

    No full text
    International audienceThe photocatalytic oxidation (PCO) of toluene was performed in a dynamic loop reactor with control of key process parameters: UV-light intensity and air flow rate. The initial concentration of toluene was fixed at 800 ppb. The relative humidity was set at 50% (i.e. 13 000 ppm) to be close to real indoor air conditions. Two photocatalytic media geometries were used in a way to optimize the contact time. Flat and pleated geometry were studied. CFD simulations were performed with ANSYS-CFXÂź computational fluid software. Influence of the contact time was assessed and related to the geometry of the material. The local contact time was evaluated to be 9 times higher regarding the pleated geometry. This latter impacts the global PCO efficiency; it plays a role in the contact time between the effluent and the photocatalytic material
    corecore