159 research outputs found

    Review on the leveraging of design information in 3D CAD models for subassemblies identification

    Get PDF
    In industrial manufacturing, both in the design and the production phase, the management of modern mechanical assemblies is becoming demanding due to their increasing complexity. The use of stable subassemblies concept constitutes a better alternative, which allows to independently treat smaller groups of the assembly's parts, also to achieve a parallel production. At this regard, several methods for automatic subassemblies identifi-cation, starting from the assembly CAD model, have been provided. However, most of the methodologies proposed rely on human intervention, especially in the model processing to make available essential data, while other details are ignored. After giving the definition of stable subassembly, this paper focuses on the application of stable subassemblies identification to industrial CAD models and highlights the issues arising. With the aim of ensuring a reliable CAD model analysis, starting point of the identification, the possible real engineering situations, both related to assembling methods and modelling techniques, are presented. Ap-proaches to algorithmically address them are then described, with the help of two examples of mechanical assemblies

    Experimental and numerical analysis of supersonic blade profiles developed for highly loaded impulse type steam turbine stages

    Get PDF
    The paper describes the results of a numerical and experimental research program addressing the aerodynamic investigation on the performance of blade profiles specifically developed for application in highly loaded impulse type turbine stages. The industrial requirements driving toward the adoption of highly loaded stage solutions are presented, along with an estimation of the profiles operating parameters. Two stator vanes and one rotor blade profile have been developed and extensively tested by means of flow field measurements and schlieren visualization in a transonic blow-down wind tunnel for linear cascades. Experimental results for the relevant operating conditions are presented, providing validation data for the CFD model used for blade design and evidencing that the main goals of the design optimization procedure have been achieved

    Sequestration of Voriconazole and Vancomycin Into Contemporary Extracorporeal Membrane Oxygenation Circuits: Anin vitroStudy

    Get PDF
    Background: Bacterial and fungal infections are common and often contribute to death in patients undergoing extracorporeal membrane oxygenation (ECMO). Drug disposition is altered during ECMO, and adsorption in the circuit is an established causative factor. Vancomycin and voriconazole are widely used, despite the lack of evidence-based prescription guidelines. Objective: The objective of this study was to determine the extraction of voriconazole and vancomycin by the Xenios/Novalung ECMO circuits. Methods: We have set up nine closed-loop ECMO circuits, consisting of four different iLAActivve® kits for neonatal, pediatric, and adult support: three iLA-ActivveMiniLung® petite kits, two iLA-ActivveMiniLung® kits, two iLA-ActivveiLA® kits, and two iLA-Activve X-lung® kits. The circuits were primed with whole blood and maintained at physiologic conditions for 24 h. Voriconazole and vancomycin were injected as a single-bolus age-related dose into the circuits. Pre-membrane (P2) blood samples were obtained at baseline and after drug injection at 2, 10, 30, 180, 360 min, and 24 h. A control sample at 2 min was collected for spontaneous drug degradation testing at 24 h. Results: Seventy-two samples were analyzed in triplicate. The mean percentage of drug recovery at 24 h was 20% for voriconazole and 62% for vancomycin. Conclusions: The extraction of voriconazole and vancomycin by contemporary ECMO circuits is clinically relevant across all age-related circuit sizes and may result in reduced drug exposure in vivo

    Analysis of LGV usage for the improvement of a customized production

    Get PDF
    The paper describes an approach for analyzing the use of a Laser-Guided Vehicle (LGV) in the context of the small and medium-sized enterprise. The use of LGVs is an efficient solution to provide more flexibility in the context of Just-In-Time production; however, the investment cost can limit this application. A methodology has been proposed in this work to analyze the technical feasibility of using an LGV in the manufacturing industry of customized products. The test case focuses on the study of a laser-guided system to optimize the handling of molds for customized production. In this scenario, an LGV is proposed to substitute manual carts used for moving molds from the warehouse to the injection machines. The traditional path included an intermediate station for pre-heating the molds in hot-air ovens. The proposed solution includes the study of an induction heating system on the LGV to optimize time and energy consumption

    Successful extracorporeal membrane oxygenation after incidental azygos vein cannulation in a neonate with right-sided congenital diaphragmatic hernia interruption of the inferior vena cava and azygos continuation

    Get PDF
    Incidental azygos vein cannulation has been reported in a few cases of neonatal extracorporeal membrane oxygenation (ECMO). This complication is described in the literature mainly in pathological conditions wherein increased central venous pressure dilates the superior vena cava (SVC), i.e., right congenital diaphragmatic hernia (CDH) or pulmonary hypertension. Azygos vein cannulation should always be suspected in cases of impaired venous return and circuit failure. Although rare, it hinders proper venous aspiration of the ECMO circuit and generally requires repositioning or replacement of the venous cannula or conversion to central cannulation. In this report, we describe a newborn with severe right CDH who required ECMO assistance, wherein incidental cannulation of the azygos vein resulted in successful functioning of the circuit because of the concomitant presence of isolated interruption of the inferior vena cava and azygos continuation. To the best of our knowledge, this is the first report of successful neonatal ECMO despite azygos vein cannulation in a patient with such rare physiology

    Oxidative stress and neonatal respiratory extracorporeal membrane oxygenation

    Get PDF
    Oxidative stress is a frequent condition in critically ill patients, especially if exposed to extracorporeal circulation, and it is associated with worse outcomes and increased mortality. The inflammation triggered by the contact of blood with a non-endogenous surface, the use of high volumes of packed red blood cells and platelets transfusion, the risk of hyperoxia and the impairment of antioxidation systems contribute to the increase of reactive oxygen species and the imbalance of the redox system. This is responsible for the increased production of superoxide anion, hydrogen peroxide, hydroxyl radicals, and peroxynitrite resulting in increased lipid peroxidation, protein oxidation, and DNA damage. The understanding of the pathophysiologic mechanisms leading to redox imbalance would pave the way for the future development of preventive approaches. This review provides an overview of the clinical impact of the oxidative stress during neonatal extracorporeal support and concludes with a brief perspective on the current antioxidant strategies, with the aim to focus on the potential oxidative stress-mediated cell damage that has been implicated in both short and long-term outcomes

    Robotic therapy : Cost, accuracy, and times. New challenges in the neonatal intensive care unit

    Get PDF
    Background: The medication process in the Neonatal Intensive Care Unit (NICU), can be challenging in terms of costs, time, and the risk of errors. Newborns, especially if born preterm, are more vulnerable to medication errors than adults. Recently, robotic medication compounding has reportedly improved the safety and efficiency of the therapeutic process. In this study, we analyze the advantages of using the I.V. Station\uae system in our NICU, compared to the manual preparation of injectable drugs in terms of accuracy, cost, and time. Method: An in vitro experimental controlled study was conducted to analyze 10 injectable powdered or liquid drugs. Accuracy was calculated within a 5% difference of the bottle weight during different stages of preparation (reconstitution, dilution, and final product). The overall cost of manual and automated preparations were calculated and compared. Descriptive statistics for each step of the process are presented as mean \ub1 standard deviation or median (range). Results: The median error observed during reconstitution, dilution, and final therapy of the drugs prepared by the I.V. Station\uae ranged within \ub15% accuracy, with narrower ranges of error compared to those prepared manually. With increasing preparations, the I.V. Station\uae consumed less materials, reduced costs, decreased preparation time, and optimized the medication process, unlike the manual method. In the 10 drugs analyzed, the time saved from using the I.V. Station\uae ranged from 16 s for acyclovir to 2 h 57 min for teicoplanin, and cost savings varied from 8% for ampicillin to 66% for teicoplanin. These advantages are also capable of continually improving as the total amount of final product increases. Conclusions: The I.V. Station\uae improved the therapeutic process in our NICU. The benefits included increased precision in drug preparation, improved safety, lowered cost, and saved time. These advantages are particularly important in areas such as the NICU, where the I.V. Station\uae could improve the delivery of the high complexity of care and a large amount of intravenous therapy typically required. In addition, these benefits may lead to the reduction in medication errors and improve patient and family care; however, additional studies will be required to confirm this hypothesis

    Cyclic nucleotide-dependent relaxation in human umbilical vessels

    Get PDF
    Umbilical vessels have a low sensitivity to dilate, and this property is speculated to have physiological implications. We aimed to investigate the different relaxing responses of human umbilical arteries (HUAs) and veins (HUVs) to agonists acting through the cAMP and cGMP pathways. Vascular rings were suspended in organ baths for isometric force measurement. Following precontraction with the thromboxane prostanoid (TP) receptor agonist U44069, concentration-response curves to the nitric oxide (NO) donor sodium nitroprusside (SNP), the soluble guanylate cyclase (sGC) stimulator BAY 41-2272, the adenylate cyclase (AC) activator forskolin, the \u3b2-adrenergic receptor agonists isoproterenol (ADRB1), salmeterol (ADRB2), and BRL37344 (ADRB3), and the phosphodiesterase (PDE) inhibitors milrinone (PDE3), rolipram (PDE4), and sildenafil (PDE5) were performed. None of the tested drugs induced a relaxation higher than 30% of the U44069-induced tone. Rings from HUAs and HUVs showed a similar relaxation to forskolin, SNP, PDE inhibitors, and ADRB agonists. BAY 41-2272 was significantly more efficient in relaxing veins than arteries. ADRB agonists evoked weak relaxations (< 20%), which were impaired in endothelium-removed vessels or in the presence of the NO synthase inhibitor L-NAME, sGC inhibitor ODQ. PKA and PKG inhibitors impaired ADBR1-mediated relaxation but did not affect ADRB2-mediated relaxation. ADRB3-mediated relaxation was impaired by PKG inhibition in HUAs and by PKA inhibition in HUVs. Although HUA and HUV rings were relaxed by BRL37344, immunohistochemistry and RT-qPCR analysis showed that, compared to ADRB1 and ADRB2, ADRB3 receptors are weakly or not expressed in umbilical vessels. In conclusion, our study confirmed the low relaxing capacity of HUAs and HUVs from term infants. ADRB-induced relaxation is partially mediated by endothelium-derived NO pathway in human umbilical vessels

    Refractive outcome in preterm newborns with ROP after propranolol treatment. A retrospective observational cohort study

    Get PDF
    Background: Recent explorative studies suggest that propranolol reduces retinopathy of prematurity (ROP) progression, but the short-term effects of propranolol treatment at 1 year of corrected age have not been extensively evaluated. Methods: A multi-center retrospective observational cohort study was conducted to assess the physical development and the refractive outcome of infants with prior ROP treated with propranolol. Forty-nine infants treated with propranolol were compared with an equal number of patients who did not receive any propranolol therapy and represent the control group, with comparable anthropometrical characteristics and stages of ROP. Results: The weight, length, and head circumference at 1 year of corrected age were similar between infants who had been treated, or not, with propranolol, without any statistically significant differences. Refractive evaluation at 1 year showed spherical equivalent values decreasing with the progression of ROP toward more severe stages of the disease, together with an increasing number of infants with severe myopia. On the contrary, no differences were observed between infants who had been treated with propranolol and those who had not. Conclusion: This study confirms that the progression of ROP induces an increase of refractive errors and suggests that propranolol itself does not affect the refractive outcome. Therefore, if the efficacy of propranolol in counteracting ROP progression is confirmed by further clinical trials, the conclusion will be that propranolol might indirectly improve the visual outcome, reducing the progression of ROP

    Importancia de la rehabilitación post-endodóntica en relación a la permanencia y funcionalidad de las piezas en boca

    Get PDF
    La micro filtración coronaria es una causa potencial de fracaso endodóntico. Ésta, junto a la caries recurrente o restauraciones fracturadas, permiten la re contaminación del sistema de conductos. La exposición de la gutapercha coronaria a la cavidad oral puede provocar la migración de bacterias hacia el ápice en cuestión de días y sus endotoxinas lo hacen con aún mayor velocidad. Por lo que se recomienda realizar la restauración lo más inmediatamente posible del diente, aunque sea con una “barrera intracoronaria” de composite o ionómero vítreo sobre la entrada a los conductos.Facultad de Odontologí
    corecore