260 research outputs found

    Spontaneous left main coronary artery dissection complicated by pseudoaneurysm formation in pregnancy: role of CT coronary angiography

    Get PDF
    We report a case of a 26-year-old female, who presented at 34 weeks of an uncomplicated pregnancy with an acute ST elevation anterior wall myocardial infarction. Cardiac catheterization suggested a left main coronary artery dissection with pseudoaneurysm formation. The patient's course was complicated by congestive heart failure. She was initially managed conservatively by a multidisciplinary team including heart failure specialists, obstetricians, and cardiovascular surgeons. 4 days after admission, her LMC was imaged by dual-source 64 slice Cardiac computed tomography, coronary dissection was identified extending to the lumen, and the presence of pseudoaneurysm was confirmed. She underwent subsequently a staged procedure, which included placement of an intra-aortic balloon pump, cesarean section, and coronary artery bypass grafting. This case illustrates the utility of coronary artery CT imaging to assess the complexity and stability of coronary artery dissections, thereby helping to determine the need for, and timing of revascularization procedures

    Decreased wheel-running activity in hamsters post myocardial infarction

    Get PDF
    Reduced exercise capacity is a key symptom and an independent determinant of mortality in patients with heart failure. We analyzed the running activity of hamsters with cardiac dysfunction after myocardial infarction. In 39 male Syrian hamsters aged 10 to 12 weeks, a myocardial infarction (MI) was produced by permanent ligation of the left coronary artery. Spontaneous running activity in a wheel was monitored daily. After four weeks, left ventricular (LV) hemodynamics (catheter tip manometry) were measured at baseline and during inotropic stimulation (isoprenaline 0.03, 0.1 and 0.3 Ī¼g/kg/min i.v.). LV infarct size was quantified using planimetry. Four weeks post MI, daily running distance was reduced stepwise in animals with small (4ā€“15 % of LV: 9.8 Ā± 3.4 km/d) and large (> 15 % of LV: 7.5 Ā± 3.5 km/d) MI, compared to sham-operated hamsters (11.5 Ā± 1.5 km/d). Similar reductions were observed in maximum speed and distance of longest running period. MI size influenced daily running distance, maximum speed, and longest running period (linear correlations, all p < 0.05). MI size also impaired LV systolic and diastolic function under isoprenaline stimulation. The results suggest that myocardial infarction reduces running capacity and isoprenaline stimulated LV function in hamsters, mimicking impaired exercise performance in patients with heart failure. Analysis of running activity in hamsters with myocardial infarction offers a unique opportunity for non-invasive and serial functional assessment of heart failure in the experimental setting

    Automatic centerline extraction of coronary arteries in coronary computed tomographic angiography

    Get PDF
    Coronary computed tomographic angiography (CCTA) is a non-invasive imaging modality for the visualization of the heart and coronary arteries. To fully exploit the potential of the CCTA datasets and apply it in clinical practice, an automated coronary artery extraction approach is needed. The purpose of this paper is to present and validate a fully automatic centerline extraction algorithm for coronary arteries in CCTA images. The algorithm is based on an improved version of Frangiā€™s vesselness filter which removes unwanted step-edge responses at the boundaries of the cardiac chambers. Building upon this new vesselness filter, the coronary artery extraction pipeline extracts the centerlines of main branches as well as side-branches automatically. This algorithm was first evaluated with a standardized evaluation framework named Rotterdam Coronary Artery Algorithm Evaluation Framework used in the MICCAI Coronary Artery Tracking challenge 2008 (CAT08). It includes 128 reference centerlines which were manually delineated. The average overlap and accuracy measures of our method were 93.7% and 0.30Ā mm, respectively, which ranked at the 1st and 3rd place compared to five other automatic methods presented in the CAT08. Secondly, in 50 clinical datasets, a total of 100 reference centerlines were generated from lumen contours in the transversal planes which were manually corrected by an expert from the cardiology department. In this evaluation, the average overlap and accuracy were 96.1% and 0.33Ā mm, respectively. The entire processing time for one dataset is less than 2Ā min on a standard desktop computer. In conclusion, our newly developed automatic approach can extract coronary arteries in CCTA images with excellent performances in extraction ability and accuracy

    Maximizing dose reductions with cardiac CT

    Get PDF
    Multidetector computed tomography has come a long way in a short time, quickly becoming a standard tool in the cardiac imaging armamentarium. The promise of plaque imaging, combined with both anatomical visualization and stenosis detection, has made this a preferred first line test of many cardiologists and radiologists. This test is well suited to rule out coronary artery disease (obstruction) and still diagnosing subclinical plaque, with may be a good target for anti-atherosclerotic therapies. There has been recent criticism against CT imaging, and cardiac CT specifically, due to the high radiation doses that being employed. New advances have allowed for dramatic dose reductions. These include more routinely performed methods such as dose modulation, and newer methods such as prospective gating or minimizing the field of view. This paper will review the different applications to reduce cardiac CT radiation doses to nominal levels, potentially expanding the applications of cardiac CT by removing one of the biggest barriers

    Performance and efficacy of 320-row computed tomography coronary angiography in patients presenting with acute chest pain: results from a clinical registry

    Get PDF
    The purpose of this study was to evaluate the performance of 320-row computed tomography angiography (CTA) in the identification of significant coronary artery disease (CAD) in patients presenting with acute chest pain and to examine the relation to outcome during follow-up. A total of 106 patients with acute chest pain underwent CTA to evaluate presence of CAD. Each CTA was classified as: normal, non-significant CAD (<50% luminal narrowing) and significant CAD (ā‰„50% luminal narrowing). CTA results were compared with quantitative coronary angiography. After discharge, the following cardiovascular events were recorded: cardiac death, non-fatal infarction, and unstable angina requiring revascularization. Among the 106 patients, 23 patients (22%) had a normal CTA, 19 patients (18%) had non-significant CAD on CTA, 59 patients (55%) had significant CAD on CTA, and 5 patients (5%) had non-diagnostic image quality. In total, 16 patients (15%) were immediately discharged after normal CTA and 90 patients (85%) underwent invasive coronary angiography. Sensitivity, specificity, and positive and negative predictive values to detect significant CAD on CTA were 100, 87, 93, and 100%, respectively. During mean follow-up of 13.7Ā months, no cardiovascular events occurred in patients with a normal CTA examination. In patients with non-significant CAD on CTA, no cardiac death or myocardial infarctions occurred and only 1 patient underwent revascularization due to unstable angina. In patients presenting with acute chest pain, an excellent clinical performance for the non-invasive assessment of significant CAD was demonstrated using CTA. Importantly, normal or non-significant CAD on CTA predicted a low rate of adverse cardiovascular events and favorable outcome during follow-up

    Coronary revascularization treatment based on dual-source computed tomography

    Get PDF
    Therapy advice based on dual-source computed tomography (DSCT) in comparison with coronary angiography (CAG) was investigated and the results evaluated after 1-year follow-up. Thirty-three consecutive patients (mean age 61.9Ā years) underwent DSCT and CAG and were evaluated independently. In an expert reading (the ā€œgold standardā€), CAG and DSCT examinations were evaluated simultaneously by an experienced radiologist and cardiologist. Based on the presence of significant stenosis and current guidelines, therapy advice was given by all readers blinded from the results of other readings and clinical information. Patients were treated based on a multidisciplinary team evaluation including all clinical information. In comparison with the gold standard, CAG had a higher specificity (91%) and positive predictive value (PPV) (95%) compared with DSCT (82% and 91%, respectively). DSCT had a higher sensitivity (96%) and negative predictive value (NPV) (89%) compared with CAG (91% and 83%, respectively). The DSCT-based therapy advice did not lead to any patient being denied the revascularization they needed according to the multidisciplinary team evaluation. During follow-up, two patients needed additional revascularization. The high NPV for DSCT for revascularization assessment indicates that DSCT could be safely used to select patients benefiting from medical therapy only

    Abdominal aortic calcification on a plain X-ray and the relation with significant coronary artery disease in asymptomatic chronic dialysis patients

    Full text link
    BACKGROUND: Coronary artery disease (CAD) is common in asymptomatic chronic dialysis patients and plays an important role in their poor survival. Early identification of these high-risk patients could improve treatment and reduce mortality. Abdominal aortic calcification (AAC) has previously been associated with CAD in autopsy studies. Since the AAC can be quantified easily using a lateral lumbar X-ray we hypothesized that the extent of AAC as assessed on a lateral lumbar X-ray might be predictive of the presence of significant CAD in dialysis patients. METHODS: All patients currently enrolled in the ICD2 trial without a history of CABG or a PCI with stent implantation were included in this study. All patients underwent CT-angiography (CTA) and a lateral X-ray of the abdomen. AAC on X-ray was quantified using a previously validated scoring system whereupon the association between AAC and the presence of significant CAD was assessed. RESULTS: A total of 90 patients were included in this study (71% male, 67ā€‰Ā±ā€‰7Ā years old). Forty-six patients were found to have significant CAD. AAC-score was significantly higher in patients with CAD (10.1ā€‰Ā±ā€‰4.9 vs 6.3ā€‰Ā±ā€‰4.6 (pā€‰<ā€‰0.05). Multivariate regression analysis revealed that AAC score is an independent predictor for the presence of CAD with a 1,2 fold higher risk per point increase (pā€‰<ā€‰0.01). The AAC score has a sensitivity of 85% and a specificity of 57% for the presence of significant CAD. CONCLUSION: This study shows that abdominal aortic calcification as assessed on a lateral lumbar X-ray is predictive for the presence of significant coronary artery disease in asymptomatic dialysis patients. This simple, non-invasive and cheap screening method could contribute to early identification of patients eligible for further screening of CAD. TRIAL REGISTRATION: NTR948, registered 10-4-2007 ; ISRCTN20479861, registered 2-5-200

    Functional assessment of coronary artery flow using adenosine stress dual-energy CT: a preliminary study

    Get PDF
    We attempted to assess coronary artery flow using adenosine-stress and dual-energy mode with dual-source CT (DE-CT). Data of 18 patients with suspected coronary arteries disease who had undergone cardiac DE-CT were retrospectively analyzed. The patients were divided into two groups: 10 patients who performed adenosine stress CT, and 8 patients who performed rest CT as controls. We reconstructed an iodine map and composite images at 120Ā kV (120Ā kV images) using raw data with scan parameters of 100 and 140Ā kV. We measured mean attenuation in the coronary artery proximal to the distal portion on both the iodine map and 120Ā kV images. Coronary enhancement ratio (CER) was calculated by dividing mean attenuation in the coronary artery by attenuation in the aortic root, and was used as an estimate of coronary enhancement. Coronary stenosis was identified as a reduction in diameter of >50% on CT angiogram, and myocardial ischemia was diagnosed by adenosine-stress myocardial perfusion scintigraphy. The iodine map showed that CER was significantly lower for ischemic territories (0.76Ā Ā±Ā 0.06) or stenosed coronary arteries (0.77Ā Ā±Ā 0.06) than for non-ischemic territories (0.95Ā Ā±Ā 0.21, PĀ =Ā 0.02) or non-stenosed coronary arteries (1.07Ā Ā±Ā 0.33, PĀ <Ā 0.001). The 120Ā kV images showed no difference in CER between these two groups. Use of CER on the iodine map separated ischemic territories from non-ischemic territories with a sensitivity of 86% and a specificity of 75%. Our quantification is the first non-invasive analytical technique for assessment of coronary artery flow using cardiac CT. CER on the iodine map is a candidate method for demonstration of alteration in coronary artery flow under adenosine stress, which is related to the physiological significance of coronary artery disease

    Reduction in downstream test utilization following introduction of coronary computed tomography in a cardiology practice

    Get PDF
    To compare utilization of non-invasive ischemic testing, invasive coronary angiography (ICA), and percutaneous coronary intervention (PCI) procedures before and after introduction of 64-slice multi-detector row coronary computed tomographic angiography (CCTA) in a large urban primary and consultative cardiology practice. We utilized a review of electronic medical records (NotesMDĀ®) and the electronic practice management system (MegawestĀ®) encompassing a 4-year period from 2004 to 2007 to determine the number of exercise treadmill (TME), supine bicycle exercise echocardiography (SBE), single photon emission computed tomography (SPECT) myocardial perfusion stress imaging (MPI), coronary calcium score (CCS), CCTA, ICA, and PCI procedures performed annually. Test utilization in the 2Ā years prior to and 2Ā years following availability of CCTA were compared. Over the 4-year period reviewed, the annual utilization of ICA decreased 45% (2,083 procedures in 2004 vs. 1,150 procedures in 2007, PĀ <Ā 0.01) and the percentage of ICA cases requiring PCI increased (19% in 2004 vs. 28% in 2007, PĀ <Ā 0.001). SPECT MPI decreased 19% (3,223 in 2004 vs. 2,614 in 2007 PĀ <Ā 0.02) and exercise stress treadmill testing decreased 49% (471 in 2004 vs. 241 in 2007 PĀ <Ā 0.02). Over the same period, there were no significant changes in measures of practice volume (office and hospital) or the annual incidence of PCI (405 cases in 2004 vs. 326 cases in 2007) but a higher percentage of patients with significant disease undergoing PCI 19% in 2004 vs. 29% in 2007 PĀ <Ā 0.01. Implementation of CCTA resulted in a significant decrease in ICA and a corresponding significant increase in the percentage of ICA cases requiring PCI, indicating that CCTA resulted in more accurate referral for ICA. The reduction in unnecessary ICA is associated with avoidance of potential morbidity and mortality associated with invasive diagnostic testing, reduction of downstream SPECT MPI and TME as well as substantial savings in health care dollars

    Detection and characteristics of microvascular obstruction in reperfused acute myocardial infarction using an optimized protocol for contrast-enhanced cardiovascular magnetic resonance imaging

    Get PDF
    Several cardiovascular magnetic resonance imaging (CMR) techniques are used to detect microvascular obstruction (MVO) after acute myocardial infarction (AMI). To determine the prevalence of MVO and gain more insight into the dynamic changes in appearance of MVO, we studied 84 consecutive patients with a reperfused AMI on average 5 and 104Ā days after admission, using an optimised single breath-hold 3D inversion recovery gradient echo pulse sequence (IR-GRE) protocol. Early MVO (2Ā min post-contrast) was detected in 53 patients (63%) and late MVO (10Ā min post-contrast) in 45 patients (54%; pā€‰=ā€‰0.008). The extent of MVO decreased from early to late imaging (4.3ā€‰Ā±ā€‰3.2% vs. 1.8ā€‰Ā±ā€‰1.8%, pā€‰<ā€‰0.001) and showed a heterogeneous pattern. At baseline, patients without MVO (early and late) had a higher left ventricular ejection fraction (LVEF) than patients with persistent late MVO (56ā€‰Ā±ā€‰7% vs. 48ā€‰Ā±ā€‰7%, pā€‰<ā€‰0.001) and LVEF was intermediate in patients with early MVO but late MVO disappearance (54ā€‰Ā±ā€‰6%). During follow-up, LVEF improved in all three subgroups but remained intermediate in patients with late MVO disappearance. This optimised single breath-hold 3D IR-GRE technique for imaging MVO early and late after contrast administration is fast, accurate and allows detection of patients with intermediate remodelling at follow-up
    • ā€¦
    corecore