17 research outputs found
Magnetic resonance mammography in the evaluation of recurrence at the prior lumpectomy site after conservative surgery and radiotherapy
INTRODUCTION: The aim was to assess the value of magnetic resonance mammography (MRM) in the detection of recurrent breast cancer on the prior lumpectomy site in patients with previous conservative surgery and radiotherapy. METHODS: Between April 1999 and July 2003, 93 consecutive patients with breast cancer treated with conservative surgery and radiotherapy underwent MRM, when a malignant lesion on the site of lumpectomy was suspected by ultrasound and/or mammography. MRM scans were evaluated by morphological and dynamic characteristics. MRM diagnosis was compared with histology or with a 36-month imaging follow-up. Enhancing areas independent of the prior lumpectomy site, incidentally detected during the MRM, were also evaluated. RESULTS: MRM findings were compared with histology in 29 patients and with a 36-month follow-up in 64 patients. MRM showed 90% sensitivity, 91.6% specificity, 56.3% positive predictive value and 98.7% negative predictive value for detection of recurrence on the surgical scar. MRM detected 13 lesions remote from the scar. The overall sensitivity, specificity, positive predictive value and negative predictive value of MRM for detection of breast malignancy were 93.8%, 90%, 62.5% and 98.8%, respectively. CONCLUSION: MRM is a sensitive method to differentiate recurrence from post-treatment changes at the prior lumpectomy site after conservative surgery and radiation therapy. The high negative predictive value of this technique can avoid unnecessary biopsies or surgical treatments
Tibial cartilage volume of the back leg versus the higher loaded front leg in elite male and female English cricket fast bowlers
The aim of this study was to determine if the fast bowling action in cricket, during which the front leg experiences about twice the loading of the back leg, causes a clinically significant difference in the normalized medial or lateral tibial cartilage volume of the higher loaded front versus the back leg
Patellar cartilage volume of the back leg versus the higher loaded front leg in current elite male english cricket fast bowlers
The aim of this study was to determine if the fast bowling action in cricket causes a positive adaptive response to increase patellar cartilage volume in the higher loaded front leg versus the back leg
Magnetic resonance imaging in size assessment of invasive breast carcinoma with an extensive intraductal component.
Contains fulltext :
79911.pdf (publisher's version ) (Open Access)BACKGROUND: Breast-conserving treatment of invasive breast carcinoma with an extensive intraductal component (EIC) is associated with DCIS-involved surgical margins and therefore it has an increased recurrence rate. EIC is a non-palpable lesion of which the size is frequently underestimated on mammography. This study was undertaken to evaluate the accuracy of MRI in size assessment of breast cancer with EIC. METHODS: 23 patients were identified and the mammographic (n = 21) and MR (n = 23) images were re-reviewed by a senior radiologist. Size on MR images was compared with histopathological tumour extent. RESULTS: The correlation of radiological size with histopathological size was r = 0.20 in mammography (p = 0.39) compared to r = 0.65 in MRI (p < 0.01). Mammography underestimated histopathological tumour size in 62%. MR images over- or underestimated tumour size in 22% and 30% of the cases, respectively. In poorly differentiated EIC, MRI adequately estimated the extent more often compared to moderately differentiated EIC (60% versus 25%, respectively). CONCLUSION: Size assessment of MRI imaging was more accurate compared to mammography. This was predominantly true for poorly differentiated EIC
The biophysical and physiological basis for mitigated elevations in heart rate with electric fan use in extreme heat and humidity
The final publication is available at Springer via http://dx.doi.org/10.1007/s00484-016-1213-0.Electric fan use in extreme heat wave conditions has been thought to be disadvantageous because it might accelerate heat gain to the body via convection. However, it has been recently shown that fan use delays increases in heart rate even at high temperatures (42 °C) in young adults. We here assess the biophysical and physiological mechanisms underlying the apparently beneficial effects of fan use. Eight males (24 ± 3 y; 80.7 ± 11.7 kg; 2.0 ± 0.1 m(2)) rested at either 36 °C or 42 °C, with (F) or without (NF) electric fan use (4.2 m/s) for 120 min while humidity increased every 7.5 min by 0.3 kPa from a baseline value of 1.6 kPa. Heart rate (HR), local sweat rate (LSR), cutaneous vascular conductance (CVC), core and mean skin temperatures, and the combined convective/radiative heat loss (C+R), evaporative heat balance requirements (Ereq) and maximum evaporative potential (Emax) were assessed. C+R was greater with fan use at 36 °C (F 8 ± 6, NF 2 ± 2 W/m(2); P = 0.04) and more negative (greater dry heat gain) with fan use at 42 °C (F -78 ± 4, NF -27 ± 2 W/m(2); P < 0.01). Consequently, Ereq was lower at 36 °C (F 38 ± 16, NF 45 ± 3 W/m(2); P = 0.04) and greater at 42 °C (F 125 ± 1, NF 74 ± 3 W/m(2); P < 0.01) with fan use. However, fan use resulted in a greater Emax at baseline humidity at both 36 °C (F 343 ± 10, NF 153 ± 5 W/m(2); P < 0.01) and 42 °C (F 376 ± 13, NF 161 ± 4 W/m(2); P < 0.01) and throughout the incremental increases in humidity. Within the humidity range that a rise in HR was prevented by fan use but not without a fan, LSR was higher in NF at both 36 °C (P = 0.04) and 42 °C (P = 0.05), and skin temperature was higher in NF at 42 °C (P = 0.05), but no differences in CVC or core temperatures were observed (all P > 0.05). These results suggest that the delayed increase in heart rate with fan use during extreme heat and humidity is associated with improved evaporative efficiency