90 research outputs found

    Contribution of thirdhand smoke to overall tobacco smoke exposure in pediatric patients: study protocol.

    Get PDF
    BackgroundThirdhand smoke (THS) is the persistent residue resulting from secondhand smoke (SHS) that accumulates in dust, objects, and on surfaces in homes where tobacco has been used, and is reemitted into air. Very little is known about the extent to which THS contributes to children's overall tobacco smoke exposure (OTS) levels, defined as their combined THS and SHS exposure. Even less is known about the effect of OTS and THS on children's health. This project will examine how different home smoking behaviors contribute to THS and OTS and if levels of THS are associated with respiratory illnesses in nonsmoking children.MethodsThis project leverages the experimental design from an ongoing pediatric emergency department-based tobacco cessation trial of caregivers who smoke and their children (NIHR01HD083354). At baseline and follow-up, we will collect urine and handwipe samples from children and samples of dust and air from the homes of smokers who smoke indoors, have smoking bans or who have quit smoking. These samples will be analyzed to examine to what extent THS pollution at home contributes to OTS exposure over and above SHS and to what extent THS continues to persist and contribute to OTS in homes of smokers who have quit or have smoking bans. Targeted and nontargeted chemical analyses of home dust samples will explore which types of THS pollutants are present in homes. Electronic medical record review will examine if THS and OTS levels are associated with child respiratory illness. Additionally, a repository of child and environmental samples will be created.DiscussionThe results of this study will be crucial to help close gaps in our understanding of the types, quantity, and clinical effects of OTS, THS exposure, and THS pollutants in a unique sample of tobacco smoke-exposed ill children and their homes. The potential impact of these findings is substantial, as currently the level of risk in OTS attributable to THS is unknown. This research has the potential to change how we protect children from OTS, by recognizing that SHS and THS exposure needs to be addressed separately and jointly as sources of pollution and exposure.Trial registrationClinicalTrials.gov Identifier: NCT02531594 . Date of registration: August 24, 2015

    Post-Operative Pain After Knee Arthroscopy and Related Factors

    Get PDF
    The aim of this study was to explore the intensity of post-arthroscopy knee pain during the first 24 hours, and to study the influence of pre-operative pain, tourniquet time and amount of surgical trauma on post-arthroscopy pain. In 78 male patients that underwent elective arthroscopic menisectomy or diagnostic arthroscopy of the knee, preoperative and post-operative pain were registered using the Visual Analogue Scale. Variance for repeated measures and for independent observations was analysed. Supplementary analgesia was required for 23% of the patients, more often in the recovery room and between 2 and 8 hours postoperatively. Of all factors analyzed, only time was statistically significant in determining the level of post-operative pain. Supplementary analgesia was required only in patients that underwent operative arthroscopy, and more often in patients with tourniquet time of more than 40 minutes. In conclusions, post-operative time is the most significant factor related to the post-arthroscopy knee pain

    MRI follow-up of conservatively treated meniscal knee lesions in general practice

    Get PDF
    Objective: To evaluate meniscal status change on follow-up MRI after 1 year, prognostic factors and association with clinical outcome in patients with conservatively treated knee injury. Methods: We analysed 403 meniscal horns in 101 conservatively treated patients (59 male; mean age 40 years) in general practice who underwent initial knee MRI within 5 weeks of trauma. We performed ordinal logistic regression analysis to analyse prognostic factors for meniscal change on follow-up MRI after 1 year, and we assessed the association with clinical outcome. Results: On follow-up MRI 49 meniscal horns had deteriorated and 18 had improved. Age (odds ratio [OR] 1.3/decade), body weight (OR 1.2/10 kg), total anterior cruciate ligament (ACL) rupture on initial MRI (OR 2.4), location in the posterior horn of the medial meniscus (OR 3.0) and an initial meniscal lesion (OR 0.3) were statistically significant predictors of meniscal MRI appearance change after 1 year, which was not associated with clinical outcome. Conclusion: In conservatively treated patients, meniscal deterioration on follow-up MRI 1 year after trauma is predicted by higher age and body weight, initial total ACL rupture, and location in the medial posterior horn. Change in MRI appearance is not associated with clinical outcome

    Exploring types of focused factories in hospital care: a multiple case study

    Get PDF
    Background: Focusing on specific treatments or diseases is proposed as a way to increase the efficiency of hospital care. The definition of "focus" or "focused factory", however, lacks clarity. Examples in health care literature relate to very different organizations.\ud Our aim was to explore the application of the focused factory concept in hospital care, including an indication of its performance, resulting in a conceptual framework that can be helpful in further identifying different types of focused factories. Thus contributing to the understanding of the diversity of examples found in the literature. - \ud \ud Methods: We conducted a cross-case comparison of four multiple-case studies into hospital care. To cover a broad array of focus, different specialty fields were selected. Each study investigated the organizational context, the degree of focus, and the operational performance. Focus was measured using an instrument translated from industry. Data were collected using both qualitative and quantitative methods and included site visits. A descriptive analysis was performed at the case study and cross-case studies level. - \ud \ud Results: The operational performance per specialty field varied considerably, even when cases showed comparable degrees of focus. Cross-case comparison showed three focus domains. The product domain considered specialty based focused factories that treated patients for a single-specialty, but did not pursue a specific strategy nor adapted work-designs or layouts. The process domain considered delivery based focused factories that treated multiple groups of patients and often pursued strategies to improve efficiency and timeliness and adapted work-designs and physical layouts to minimize delays. The product-process domain considered procedure based focused factories that treated a single well-defined group of patients offering one type of treatment. The strategic focusing decisions and the design of the care delivery system appeared especially important for delivery and procedure based focused factories. - \ud \ud Conclusions: Focus in hospital care relates to limitations on the patient group treated and the range of services offered. Based on these two dimensions, we identified three types of focused factories: specialty based, delivery based, and procedure based. Focus could lead to better operational performance, but only when clear strategic focusing decisions are made

    Stable isotope sales: Mound Facility customer and shipment summaries, FY 1981

    Get PDF
    A listing is given of Mound Facility's sales of stable isotopes of noble gases, carbon, oxygen, nitrogen, chlorine, and sulfur for Fiscal Year 1981. Purchasers are listed alphabetically and are divided into domestic and foreign groups. A cross-reference index by location is included for domestic customers. Cross-reference listings by isotope purchased are included for all customers

    Step-frequency radar imaging for nondestructive evaluation (NDE) and ground-penetrating radar (GPR) applications

    No full text
    We describe a step-frequency microwave radar imaging system that is suitable for nondestructive evaluation (NDE) and ground-penetrating radar (GPR) applications. The system includes a computer-automated microwave measurement apparatus along with nonlinear inverse scattering imaging algorithms. Through the use of an inverse Fourier transform, the SFR data is transformed into a synthetic time-domain pulse, and imaging algorithms are applied to the time-domain data. A calibration procedure involving the use of calibration targets is described in order to remove pulse distortions due to the effective aperture and dispersive nature of the antennas, as well as those distortions due to connectors, transmission lines, directional couplers and amplifiers. Reconstructions of various metallic and dielectric scattering objects including metallic rods, glass rods and plastic PVC pipes from real measurement data collected in our laboratory are shown.link_to_subscribed_fulltex

    Letter to the Editors: A Reply

    No full text
    • …
    corecore