512 research outputs found

    Comparison of glottic views and intubation times in the supine and 25 degree back-up positions

    Get PDF
    Background: We explored whether positioning patients in a 25° back-up sniffing position improved glottic views and ease of intubation. Methods: In the first part of the study, patients were intubated in the standard supine sniffing position. In the second part, the back of the operating table was raised 25° from the horizontal by flexion of the torso at the hips while maintaining the sniffing position. The best view obtained during laryngoscopy was assessed using the Cormack and Lehane classification and Percentage of Glottic Opening (POGO) score. The number of attempts at both laryngoscopy and tracheal intubation, together with the use of ancillary equipment and manoeuvres were recorded. The ease of intubation was indirectly assessed by recording the time interval between beginning of laryngoscopy and insertion of the tracheal tube. Results: Seven hundred eighty one unselected surgical patients scheduled for non-emergency surgery were included. In the back-up position, ancillary laryngeal manoeuvres, which included cricoid pressure, backwards upwards rightward pressure and external laryngeal manipulation, were required less frequently (19.6 % versus 24. 6 %, p = 0.004). The time from beginning of laryngoscopy to insertion of the tracheal tube was 14 % shorter (median time 24 versus 28 s, p = 0.031) in the back-up position. There was no significant difference in glottic views. Conclusions: The 25° back-up position improved the ease of intubation as judged by the need for fewer ancillary manoeuvres and shorter time for intubation. Trial registration: ClinicalTrials.gov Identifier: NCT02934347 registered retrospectively on 14th Oct 2016

    Effect of private insurance incentive policy reforms on trends in coronary revascularisation procedures in the private and public health sectors in Western Australia: A cohort study

    Get PDF
    Background: The Australian federal government introduced private health insurance incentive policy reforms in 2000 that increased the uptake of private health insurance in Australia. There is currently a lack of evidence on the effect of the policy reforms on access to cardiovascular interventions in public and private hospitals in Australia. The aim was to investigate whether the increased private health insurance uptake influenced trends in emergency and elective coronary artery revascularisation procedures (CARPs) for private and public patients. Methods: We included 34,423 incident CARPs from Western Australia during 1995-2008 in this study. Rates of emergency and elective CARPs were stratified for publicly and privately funded patients. The average annual percent change (AAPC) in trend was calculated before and after 2000 using joinpoint regression. Results: The rate of emergency CARPs, which were predominantly percutaneous coronary interventions (PCIs) with stenting, increased throughout the study period for both public and private patients (AAPC=12.9%, 95% CI=5.0,22.0 and 14.1%, 95% CI=9.8,18.6, respectively) with no significant difference in trends before and after policy implementation. The rate of elective PCIs with stenting from 2000 onwards remained relatively stable for public patients (AAPC=−6.0, 95% C= −16.9,6.4), but increased by 4.1% on average annually (95% CI=1.8,6.3) for private patients (Pdifference=0.04 between groups). This rate increase for private patients was only seen in people aged over 65 years and people residing in high socioeconomic areas.Conclusions: The private health insurance incentive policy reforms are a likely contributing factor in the shift in 2000 from public to privately-funded elective PCIs with stenting. These reforms as well as the increasing number of private hospitals may have been successful in increasing the availability of publicly-funded beds since 2000

    A randomised, controlled crossover comparison of the C-MAC videolaryngoscope with direct laryngoscopy in 150 patients during routine induction of anaesthesia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The C-MAC<sup>Âź </sup>(Karl Storz, Tuttlingen, Germany) has recently been introduced as a new device for videolaryngoscopy guided intubation. The purpose of the present study was to compare for the first time the C-MAC with conventional direct laryngoscopy in 150 patients during routine induction of anaesthesia.</p> <p>Methods</p> <p>After approval of the institutional review board and written informed consent, 150 patients (ASA I-III) with general anaesthesia were enrolled. Computer-based open crossover randomisation was used to determine the sequence of the three laryngoscopies: Conventional direct laryngoscopy (HEINE Macintosh classic, Herrsching, Germany; blade sizes 3 or 4; <it>DL </it>group), C-MAC size 3 (<it>C-MAC3 </it>group) and C-MAC size 4 (<it>C-MAC4 </it>group) videolaryngoscopy, respectively. After 50 patients, laryngoscopy technique in the C-MAC4 group was changed to the straight blade technique described by Miller (C-MAC4/SBT).</p> <p>Results</p> <p>Including all 150 patients (70 male, aged (median [range]) 53 [20-82] years, 80 [48-179] kg), there was no difference of glottic view between DL, C-MAC3, C-MAC4, and C-MAC4/SBT groups; however, worst glottic view (C/L 4) was only seen with DL, but not with C-MAC videolaryngoscopy. In the subgroup of patients that had suboptimal glottic view with DL (C/L≄2a; n = 24), glottic view was improved in the C-MAC4/SBT group; C/L class improved by three classes in 5 patients, by two classes in 2 patients, by one class in 8 patients, remained unchanged in 8 patients, or decreased by two classes in 1 patient. The median (range) time taken for tracheal intubation in the DL, C-MAC3, C-MAC4 and C-MAC4/SBT groups was 8 sec (2-91 sec; n = 44), 10 sec (2-60 sec; n = 37), 8 sec (5-80 sec; n = 18) and 12 sec (2-70 sec; n = 51), respectively.</p> <p>Conclusions</p> <p>Combining the benefits of conventional direct laryngoscopy and videolaryngoscopy in one device, the C-MAC may serve as a standard intubation device for both routine airway management and educational purposes. However, in patients with suboptimal glottic view (C/L≄2a), the C-MAC size 4 with straight blade technique may reduce the number of C/L 3 or C/L 4 views, and therefore facilitate intubation. Further studies on patients with difficult airway should be performed to confirm these findings.</p

    Visual gene developer: a fully programmable bioinformatics software for synthetic gene optimization

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Direct gene synthesis is becoming more popular owing to decreases in gene synthesis pricing. Compared with using natural genes, gene synthesis provides a good opportunity to optimize gene sequence for specific applications. In order to facilitate gene optimization, we have developed a stand-alone software called Visual Gene Developer.</p> <p>Results</p> <p>The software not only provides general functions for gene analysis and optimization along with an interactive user-friendly interface, but also includes unique features such as programming capability, dedicated mRNA secondary structure prediction, artificial neural network modeling, network & multi-threaded computing, and user-accessible programming modules. The software allows a user to analyze and optimize a sequence using main menu functions or specialized module windows. Alternatively, gene optimization can be initiated by designing a gene construct and configuring an optimization strategy. A user can choose several predefined or user-defined algorithms to design a complicated strategy. The software provides expandable functionality as platform software supporting module development using popular script languages such as VBScript and JScript in the software programming environment.</p> <p>Conclusion</p> <p>Visual Gene Developer is useful for both researchers who want to quickly analyze and optimize genes, and those who are interested in developing and testing new algorithms in bioinformatics. The software is available for free download at <it><url>http://www.visualgenedeveloper.net</url></it>.</p

    Angular and Current-Target Correlations in Deep Inelastic Scattering at HERA

    Get PDF
    Correlations between charged particles in deep inelastic ep scattering have been studied in the Breit frame with the ZEUS detector at HERA using an integrated luminosity of 6.4 pb-1. Short-range correlations are analysed in terms of the angular separation between current-region particles within a cone centred around the virtual photon axis. Long-range correlations between the current and target regions have also been measured. The data support predictions for the scaling behaviour of the angular correlations at high Q2 and for anti-correlations between the current and target regions over a large range in Q2 and in the Bjorken scaling variable x. Analytic QCD calculations and Monte Carlo models correctly describe the trends of the data at high Q2, but show quantitative discrepancies. The data show differences between the correlations in deep inelastic scattering and e+e- annihilation.Comment: 26 pages including 10 figures (submitted to Eur. J. Phys. C
    • 

    corecore